LM63CIMA National Semiconductor, LM63CIMA Datasheet - Page 6

no-image

LM63CIMA

Manufacturer Part Number
LM63CIMA
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM63CIMA

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
SOIC N
Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM63CIMA
Manufacturer:
NS
Quantity:
8
Part Number:
LM63CIMA
Manufacturer:
NS
Quantity:
300
Part Number:
LM63CIMA
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM63CIMAX
Manufacturer:
RENESAS
Quantity:
5 220
Part Number:
LM63CIMAX
Manufacturer:
NSC
Quantity:
8 000
Part Number:
LM63CIMAX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM63CIMAX
Quantity:
2 000
Company:
Part Number:
LM63CIMAX
Quantity:
2 500
Part Number:
LM63CIMAX-NOPB
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM63CIMAX/NOPB
Quantity:
25 000
www.national.com
f
t
t
t
t
t
t
t
t
t
t
t
t
SMB
LOW
HIGH
R
F
OF
TIMEOUT
SU:DAT
HD:DAT
HD:STA
SU:STO
SU:STA
BUF
Symbol
SMBus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for V
pF. Boldface limits apply for T
characteristics of the LM63 fully meet or exceed the published specifications of the SMBus version 2.0. The following parameters
are the timing relationships between SMBCLK and SMBDAT signals related to the LM63. They adhere to, but are not necessarily
the same as the SMBus bus specifications.
SMBus Clock Frequency
SMBus Clock Low Time
SMBus Clock High Time
SMBus Rise Time
SMBus Fall Time
Output Fall Time
SMBData and SMBCLK Time Low for Reset of
Serial Interface See
Data In Setup Time to SMBCLK High
Data Out Hold Time after SMBCLK Low
Hold Time after (Repeated) Start Condition. After
this period the first clock is generated.
Stop Condition SMBCLK High to SMBDAT Low
(Stop Condition Setup)
SMBus Repeated Start-Condition Setup Time,
SMBCLK High to SMBDAT Low
SMBus Free Time between Stop and Start
Conditions
Parameter
(Note
A
SMBus Timing Diagram for SMBCLK and SMBDAT Signals
= T
13)
J
; T
MIN
T
A
T
MAX
DD
; all other limits T
= +3.0 VDC to +3.6 VDC, C
From V
From V
(Note
(Note
C
L
= 400 pF, I
6
11)
12)
IN(0) max
IN(1) min
A
O
to V
to V
= T
= 3 mA
Conditions
IN(1) min
J
IN(0) max
= +25°C, unless otherwise noted. The switching
L
(load capacitance) on output lines = 80
(Note
Limits
100
250
250
300
930
100
4.7
4.0
0.3
4.0
4.7
4.7
10
50
25
35
1
8)
20057004
kHz (max)
kHz (min)
ms (max)
µs (max)
µs (max)
µs (max)
ns (max)
ms (min)
ns (max)
µs (min)
µs (min)
ns (min)
ns (min)
µs (min)
ns (min)
µs (min)
µs (min)
(Limit)
Units

Related parts for LM63CIMA