Specifications of LH28F160BGE-BTL10

Cell Type
NOR
Density
16Mb
Access Time (max)
100ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
20b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Package Type
TSOP-I
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
1M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant
NOTES :
1. Bus operations are defined in Table 1.
2. X = Any valid address within the device.
3. SRD = Data read from status register. See Table 5 for a
4. Following the Read Identifier Codes command, read
Read Array/Reset
Read Identifier Codes
Read Status Register
Clear Status Register
Block Erase
Word Write
Block Erase and
Word Write Suspend
Block Erase and
Word Write Resume
IA = Identifier code address : see Fig. 2.
BA = Address within the block being erased.
WA = Address of memory location to be written.
WD = Data to be written at location WA. Data is latched
ID = Data read from identifier codes.
operations access manufacture and device codes. See
Section 4.2 for read identifier code data.
COMMAND
on the rising edge of WE# or CE# (whichever
goes high first).
description of the status register bits.
BUS CYCLES
REQ
≥ 2
1
2
1
2
2
1
1
Table 2 Command Definitions
D.
NOTE
5, 6
4
5
5
5
Oper
- 11 -
Write
Write
Write
Write
Write
Write
Write
Write
(NOTE 1)
FIRST BUS CYCLE
5. If the block is boot block, WP# must be at V
6. Either 40H or 10H is recognized by the WSM as the
7. Commands other than those shown above are reserved
Addr
must be at V
operations. Attempts to issue a block erase or word write
to a boot block while WP# is V
word write setup.
by SHARP for future device implementations and should
not be used.
WA
BA
(NOTE 2)
X
X
X
X
X
X
(NOTE 7)
Data
40H or 10H
FFH
B0H
D0H
90H
70H
50H
20H
HH
(NOTE 3)
to enable block erase or word write
LH28F160BG-TL/BGH-TL
Oper
Read
Read
Write
Write
SECOND BUS CYCLE
(NOTE 1)
IH
or RP# is V
Addr
WA
BA
IA
(NOTE 2)
X
IH
Data
IH
.
SRD
D0H
WD
or RP#
ID
(NOTE 3)