HW1M-LF0101-20 IDEC, HW1M-LF0101-20 Datasheet - Page 7

84C4813

HW1M-LF0101-20

Manufacturer Part Number
HW1M-LF0101-20
Description
84C4813
Manufacturer
IDEC
Datasheet
The Type No. development charts shown below can be used to specify control units other than those listed on the following
pages. Gold-plated silver contacts are also available.
Emergency Stop Switches
For emergency stop purposes, these switches must contain
at least one NC contact block.
Pushbuttons
Pilot Lights
HW1B-V4 11 R -MAU
Note:
Push-pull type HW1B-Y2 can have a maximum of two contact
blocks.
HW1B-M1 11 R -MAU
HW1P-1 H 2 R
Note:
Full voltage type is not supplied with a lamp.
Transformer and DC-DC converter types contain an LED lamp
(LSTD-6➁) or incandescent lamp (LS-6).
Ordering Information
Optional contact
Button/lens color code
Contact arrangement code
Optional contact
Button color code
Contact arrangement code
Lens color code
Lamp code
Operating voltage code
MAU:
01: 1NC
02: 2NC
12: 1NO-2NC
31: 3NO-1NC
13: 1NO-3NC
MAU:
10: 1NO
11: 1NO-1NC
02: 2NC
12: 1NO-2NC
03: 3NC
22: 2NO-2NC
40: 4NO
0:
2:
3:
4:
5:
6:
7:
Q:
H:
H2: Transformer (115/120V AC)
M:
M4: Transformer (230/240V AC)
S:
T:
T8: Transformer (480V AC)
D:
HW
Without lamp
LED (6V: LSTD)
LED (12V: LSTD)
LED (24V: LSTD)
Incandescent (6V: LS-6)
Incandescent (12V: LS-8)
Incandescent (24V: LS-3)
Transformer (100/110V AC)
Transformer (200/220V AC)
Transformer (380V AC)
Transformer (400/440V AC)
DC-DC converter (110V DC)
Full voltage
Gold-plated silver contact
Gold-plated silver contact
Series
11: 1NO-1NC
21: 2NO-1NC
03: 3NC
22: 2NO-2NC
04: 4NC
01: 1NC
20: 2NO
21: 2NO-1NC
30: 3NO
31: 3NO-1NC
13: 1NO-3NC
04: 4NC
Control Units (Ordering Information)
Illuminated Pushbuttons
Selector Switches
HW1L-M1 11 H 2 R -MAU
Note:
Full voltage type is not supplied with a lamp.
Transformer and DC-DC converter types contain an LED lamp
(LSTD-6➁) or incandescent lamp (LS-6).
Transformer and DC-DC converter types can have two or four
contact blocks only.
HW1S-3 S T 22N9 -MAU
Optional contact
Lens color code
Lamp code
Operating voltage code
Contact arrangement code
Optional contact
Contact code
Knob operator
Cam code
MAU: Gold-plated silver contact
0:
2:
3:
4:
5:
6:
7:
Q:
H:
H2: Transformer (115/120V AC)
M:
M4: Transformer (230/240V AC)
S:
T:
T8: Transformer (480V AC)
D:
10: 1NO
11: 1NO-1NC
02: 2NC
12: 1NO-2NC
03: 3NC
22: 2NO-2NC
40: 4NO
MAU:
J
S
(none)
Without lamp
LED (6V: LSTD)
LED (12V: LSTD)
LED (24V: LSTD)
Incandescent (6V: LS-6)
Incandescent (12V: LS-8)
Incandescent (24V: LS-3)
Full voltage
Transformer (100/110V AC)
Transformer (200/220V AC)
Transformer (380V AC)
Transformer (400/440V AC)
DC-DC converter (110V DC)
Gold-plated silver contact
01: 1NC
20: 2NO
21: 2NO-1NC
30: 3NO
31: 3NO-1NC
13: 1NO-3NC
04: 4NC
ø22