LUFDH11 TELEMECANIQUE, LUFDH11 Datasheet

55T6470

LUFDH11

Manufacturer Part Number
LUFDH11
Description
55T6470
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of LUFDH11

Accessory Type
Motor Starter Function Module - Thermal Overload Signalling
Rohs Compliant
Yes
For Use With
TeSys U Starter-controllers
1 1
Discover
LUB 12, LUB 32
LUB 120, LUB 320
1/62
1
2
3
TeSys U motor starters –
open version
Starter-controller
Non-reversing power bases
Two types of bases are available, each in two versions:
b
b
or communication module: 12 A and 32 A versions.
b
b
b
Max. current (Ith): 5 A 1 NO, 1 NC.
b
and control functions to EN 60947-6-2.
b
Rating (A)
Breaking
capacity (kA)
Rating (A)
Breaking
capacity (kA)
The Standard bases are fitted with auxiliary contacts and a fixed terminal block.
Rating (A)
Breaking
capacity (kA)
Rating (A)
Breaking
capacity (kA)
b
remote indication and coil control.
b
designed to receive the function modules (communication, alarm, etc.) can be
closed off, if necessary.
control
to communication module LUF C00, LUL C033, ASILUF C51,
local coil control
communication module LUL C07, LUL C08, LUL C09, LUL C15,
wire remote indication
References for Standard power bases
Voltage (V)
References for Advanced power bases
Voltage (V)
Terminal block for built-in auxiliary contacts
Description
1
2
3
Common characteristics
Terminal blocks for Advanced power bases
LUB12, LUB32 Standard power bases: 12 A and 32 A versions.
Advanced power bases for use in conjunction with LUB120, LUB320 function
Breaking capacity: 50 kA at 400 V.
Ratings: 12 A or 32 A at 400 V.
Built-in auxiliary contacts: max. operating voltage (Up): 690 V AC, 250 V DC.
Guaranteed continuity of service (complete coordination) between the protection
Connection by screw clamp terminal.
3 types of terminal blocks are available, providing different types of pole status
A cover is always supplied for each terminal block so that the top cavity of the base
Single terminal block for wire remote indication and local coil
Terminal block with status remote indication cable
Terminal block with a cable for controlling the coil via
y 440 V
12
50
32
50
y 440 V
12
50
32
50
500 V
12
10
23
10
500 V
12
10
23
10
690 V
9
4
21
9
690 V
9
4
21
9
Reference
LU9B N11
LU9B N11C
LU9B N11L
Reference
LUB12
LUB32
Reference
LUB2 B120
LUB2 B320
Weight (kg)
0.900
1.270
Weight (kg)
0.865
0.865

Related parts for LUFDH11

LUFDH11 Summary of contents

Page 1

Discover LUB 12, LUB LUB 120, LUB 320 1/62 TeSys U motor starters – open version Starter-controller Non-reversing power bases Two types of bases are available, each in two versions: b LUB12, LUB32 Standard ...

Page 2

Discover Vertical mounting TeSys U motor starters – open version Starter-controller Non-reversing and reversing power bases "Reverser" power bases The reverser power bases (non-reversing and reversing) consist of a combined power base and reverser block ...

Page 3

References Covers and for empty cavities are supplied with 3 4 the basic module. 1/64 Signalling contacts Non-reversing power base Reminder: TeSys U is similar to a motor protection circuit breaker and a contactor sharing ...

Page 4

... They reproduce the status of the common power contacts (NO contacts) or the reverse status (NC contacts). Additional plug-in module with 2 auxiliary contacts The contacts built into the power base are used to control the reverser block. To remotely indicate the status of the power poles, one of the following accessories must be used. Item Composition ...

Page 5

References 1/66 TeSys motor starters – open version TeSys U starter-controllers Pre-wired system for power connections Pre-wired system for power connections Application Pitch Item Description mm Sets ...

Page 6

... References TeSys motor starters – open version TeSys U starter-controllers Limiter blocks and accessories Limiter blocks and accessories Application Item Breaking Mounting capacity Iq y 440 V 690 130 70 Direct on power Limiter base disconnector (3) (5) 100 35 Separate Limiter (3) 8 130 70 Limiter-disconnector LUA LF1 Limiter cartridge ...

Page 7

References 1/68 TeSys motor starters – open version TeSys U starter-controllers Extended rotary handle Allows a circuit-breaker or a TeSys U starter-controller installed in back of an enclosure to be operated from the front ...

Page 8

References TeSys motor starters – open version TeSys U starter-controllers Remote controls - small handle Description Item Reference Handle for mounting in the MCC LU9 AP20 drawer with fixing kit Weight kg ...

Page 9

Selection Operating characteristics Control units 1 1 Thermal overload protection Overcurrent protection Short-circuit protection Protection against phase loss 2 Protection against phase imbalance Earth fault protection (equipment protection only) Tripping class Motor type Thermal overload test function 3 Overtorque No-load ...

Page 10

References LUCA pppp LUCA pppp LUCB pppp LUCB pppp LUB p2 + LUCA pppp LUB p2 + LUCA pppp LUB p2 + LUCB pppp LUB p2 + LUCB pppp Characteristics: ...

Page 11

References LUCMppBL LUCMppBL LUB p2 + LUCM ppBL LUB p2 + LUCM ppBL 7 8 XBT NU400 XBT NU400 9 10 Characteristics: Characteristics: Characteristics: Characteristics: Schemes: Schemes: Schemes: Schemes: pages 1/98 ...

Page 12

References LUB p2 + LUCB pppp LUB p2 + LUCB pppp + + LUFW 10 or LUF Vp LUFW 10 or LUF 200 200 100 100 2.2 kW 2.2 ...

Related keywords