DSO7032A-GSA AGILENT TECHNOLOGIES, DSO7032A-GSA Datasheet

69R7201

DSO7032A-GSA

Manufacturer Part Number
DSO7032A-GSA
Description
69R7201
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of DSO7032A-GSA

Scope Type
Digital
Scope Channels
2
Bandwidth
350MHz
Meter Display Type
XGA LCD
Sampling Rate
2GSPS
Input Impedance
1Mohm
Rise Time
1ns
Input Voltage
40V P-p
Supply Voltage Min
100V
Rohs Compliant
NA
Agilent Technologies
Infi niiVision 7000A Series Oscilloscopes
Data Sheet
Engineered for the best signal visibility

DSO7032A-GSA Summary of contents

Page 1

... Agilent Technologies Infi niiVision 7000A Series Oscilloscopes Data Sheet Engineered for the best signal visibility ...

Page 2

... The Infi niiVision 7000A Series offers bandwidths GHz. Each model, equipped with a large 12.1” XGA LCD display, comes in an whisper-quiet package that is just 6.5” deep and weighs only 13 pounds. Model Bandwidth Sample rate DSO7012A DSO7014A 100 MHz 2 GSa/s MSO7012A MSO7014A DSO7032A DSO7034A 350 MHz 2 GSa/s MSO7032A MSO7034A DSO7052A DSO7054A 500 MHz 4 GSa/s MSO7052A ...

Page 3

What gives the Infi niiVision 7000A Series the best signal visibility? 1. Biggest display Oscilloscopes are visual tools and large, high-resolution screens make the prod- uct better. Bigger displays have become increasingly important as general purpose scopes need more space ...

Page 4

Your design has analog, digital and serial signals ... shouldn’t your scope? Analog GHz bandwidth and GSa/s sample rate Digital: 16 digital timing channels with mixed signal triggering Serial: Hardware-accelerated decode and 2 2 ...

Page 5

Other useful features High resolution mode. Offers bits of vertical resolution in real-time, single-shot mode. This is accomplished by serially fi ltering sequential data points and mapping the fi ltered results to the display when operating at ...

Page 6

Why does a fast update rate matter? While bandwidth, sample rate and memory depth are key criteria for deciding which scope to purchase, an equally important characteristic is update rate. What is update rate? Update rate is how many waveforms ...

Page 7

How update rate affects signal visibility Capturing random and infrequent events on an oscilloscope is all about statistical probabilities. The key to improving the probability of capturing a signal anomaly is to minimize dead-time and take more pictures of the ...

Page 8

Software applications Mask testing uncovers an infrequent signal anomaly. Use segmented memory to optimize available memory. 2 View on-screen serial decode packet. Trigger on and decode RS-232/UART transmission. 8 Mask testing (N5455A or Option LMT) Agilent’s ...

Page 9

Software applications Trigger on and decode CAN serial packets. Time-correlated display of the FlexRay physical layer signal with protocol decoding. On-screen serial decode of an SPI packet Time-correlated display of the MIL-STD 1553 physical layer signal with protocol decoding. Debug ...

Page 10

Software applications and other accessories Use your scope to quickly make and analyze power measurements. Vector signal analysis software (89601A) Expand the measurement capability of your scope with the 89601A vector signal analysis software. This advanced DSP based software takes ...

Page 11

Probes and accessories Probe type Key characteristics Passive probes: most common type of probe, rugged and economical with bandwidth generally lower than 600 MHz 10070C 1:1 20 MHz with probe ID 10073C 10:1 500 MHz with probe ID (standard with ...

Page 12

Connectivity The 7000A Series scopes come with the most comprehensive connectivity tools in their class. LXI class C LAN eXtensions for Instrumentation (LXI standards-based architecture for test systems. By specifying the interaction of system components, LXI enables fast ...

Page 13

Agilent Infi niiVision Portfolio Agilent’s Infi niiVision lineup includes 5000, 6000, 7000A and 7000B Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specifi c ...

Page 14

Agilent Infi niiVision 7000A Series oscilloscopes: Engineered for the best signal visibility 12.1” large display makes it easier to view analog, digital and serial signals. High-resolution color display with XGA resolution and 256 levels of intensity reveals subtle details that ...

Page 15

Autoscale lets you quickly display any analog or digital active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory. Dedicated front panel controls make it easy to access the most common scope controls, ...

Page 16

Performance characteristics Acquisition: scope channels Sample rate Memory depth Standard Vertical resolution Peak detection Averaging High resolution mode Filter Acquisition: digital channels (7000A Series MSO or MSO-upgraded 7000A Series DSO) Sample rate Maximum input frequency Memory depth Standard Standard Vertical ...

Page 17

Performance characteristics Vertical system: scope channels Scope channels Bandwidth (–3 dB)* AC coupled Calculated rise time (=0.35/bandwidth) Single-shot bandwidth Range 1 Maximum input Offset range Dynamic range Input impedance Coupling BW limit Channel-to-channel isolation Standard probes Probe ID * Denotes ...

Page 18

Performance characteristics Vertical system: scope channels (continued) ESD tolerance Noise, RMS, input shorted DC vertical gain accuracy vertical offset accuracy 1 Single cursor accuracy 1 Dual cursor accuracy* * Denotes warranted specifications, all others are typical. Specifications are ...

Page 19

Performance characteristics Horizontal Range Resolution Time scale accuracy* Vernier Delay range Analog delta-t accuracy Logic delta-t accuracy Modes XY Reference positions Segmented memory re-arm time Trigger system Sources Modes Holdoff time Trigger jitter * Denotes warranted specification. Specifications are valid ...

Page 20

Performance characteristics Trigger system (continued) Selections Edge Pattern Pulse width TV Sequence CAN FlexRay LIN USB SPI RS-232/UART Duration MIL-STD 1553 20 (continued) Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I ...

Page 21

Performance characteristics Trigger system (continued) Nth edge burst Autoscale Scope channel triggering Range (internal) Sensitivity* Coupling Digital (D15 - D0) channel triggering (7000A Series MSO or MSO-upgraded 7000A Series DSO) Threshold range (user defined) Threshold accuracy Predefined thresholds External (EXT) ...

Page 22

Performance characteristics Display system Display Throughput of scope channels Resolution Controls Built-in help system Real-time clock Measurement features Automatic measurements Voltage (scope channels only) Time Counter Threshold definition Cursors Waveform math Measurement statistics 22 (continued) 12.1-inch (255 mm x 184 ...

Page 23

Performance characteristics FFT Points Source of FFT Window Noise floor Amplitude Frequency resolution Maximum frequency Storage Save/recall (non-volatile) Storage type and format I/O Standard ports Max transfer rate Supported printers via USB General characteristics Physical size (WxHxD) Weight Probe comp ...

Page 24

Performance characteristics General characteristics (continued) Trigger out 10 MHz ref in/out Kensington lock Power requirements Line voltage range Line frequency Power usage Environmental characteristics Ambient temperature Humidity Altitude Vibration Shock Pollution degree Typical operator noise Indoor use Other Measurement categories ...

Page 25

... Model Bandwidth Sample rate DSO7012A 100 MHz 2 GSa/s DSO7014A 100 MHz 2 GSa/s MSO7012A 100 MHz 2 GSa/s MSO7014A 100 MHz 2 GSa/s DSO7032A 350 MHz 2 GSa/s DSO7034A 350 MHz 2 GSa/s MSO7032A 350 MHz 2 GSa/s MSO7034A 350 MHz 2 GSa/s DSO7052A 500 MHz 4 GSa/s DSO7054A ...

Page 26

Ordering information (continued) Options Product Description DSO to MSO upgrade* N2741A for DSO701xA N2735A for DSO703xA N2736A for DSO705xA N2737A for DSO710xA SEC Secure Environment Mode - Provides compliance with National Industrial Security Program Operating Manual (NISPOM) Chapter 8 requirements ...

Page 27

... Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications 27 ...

Page 28

... For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com www.agilent.com/find/7000A For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 ...