Light Output Patterns
Specifications
Note 1 - Measured at 10 ft (3m) @ 24 Vdc. Subtract 3 dBA for models with strobes. Note 2 - Temporal audible pattern is defined as: ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec
OFF, ½ sec ON, 1½ sec OFF, then repeat cycle. Integrity audible will not be affected by Genesis signal silence operation when on the same two wire circuit with Genesis horn
strobes.
Page 4 of 6
-90
Rated Strobe Output - candela (cd)
UL 1638
UL 1971
ULC S526
Standalone Synchronization
Characteristics (note 2)
Operating Volts
Horn Output (note 1)
Horn Current
Strobe Flash Synchronization
Synchronization Sources
Strobe Marking
Flash Tube Enclosure
Housing
Wire Connections
INDOOR Operating Environment
OUTDOOR Operating Environment
(must use weatherproof box)
Mounting - INDOOR
Mounting - OUTDOOR
Agency Listings
-75
15 cd (-5A) Series Strobes
-60
30 20 10
-45
30
20
10
cd
10
20
30
-30
Horizontal Output
Average
-90 -75
90
Vertical Output
-15
75
-60
60
cd
r
0
-45
45
UL min
15
10 20 30
-30
30
-15
15
0
30
45
60
75
90
15/75 cd (-7A) Series Strobes
-90
-75
-60
100
100
-45
100
100
50
cd
50
-30
Horizontal Output
Average
Vertical Output
-90 -75
90
50
-15
75
Supplied with LKW-1 “FIRE” red letters, vertical both sides (Wall Mount) - see LKW and LKC series for ceiling
Synchronized at one flash per second. External control module necessary to meet UL 1971 synchronization
cd
0
-60
r
60
Strobe flash at 1 per second within 200 milliseconds on common circuit Horn pulses at temporal rate
-45
45
UL min
15
Anechoic: High Setting - 104 dBA (peak)/98 dBA (avg); Low Setting - 99 dBA (peak)/94 dBA (avg)
-30
30
-15
15
50
N/A (horn only)
30
0
45
2447TH-R
(All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule)
Textured, color impregnated engineered plastics - exceeds 94V-0 UL flammability rating
Terminals - separate, polarized inputs for Horn & Strobe, #12 AWG (2.5mm²) maximum
60
75
100
90
Flush: North-American 2-gang box, 3” high x 4” wide x 2¾” (69 mm) minimum
Surface: 2459-SMB-R Back box Bi-directional: 2400A-BDF Mounting Frame
UL 1971, UL 1638, UL 464, ULC S526, ULC S525, MEA, CSFM, FM. CE
32-120° F (0-49° C) ambient temperature. 93% relative humidity @ 40° C
-90
Reverberent: High Setting - 85 dBA (continuous)/82 dBA (temporal);
-75
30 cd (-3A) Series Strobes
-60
60
-45
60
40
20
cd
20
40
60
-30
40
Low Output: 20 mA @ 24 Vdc; 28 mA @ 24 Vrms FWR
requirements of 10 milliseconds over a two-hour period.
EG1M-RM, EBPS6A, EBPS10A, E-NAC, E-FSC, E-FSA
Horizontal Output
Average
High Output: 40 mA @ 24 Vdc; 55mA @ 24 Vrms FWR
-90 -75
90
Vertical Output
Low Setting - 82 dBA (continuous)/75 dBA (temporal)
-15
20
75
-31-150° F (-35-66° C) ambient temperature
-60
cd
60
within 200 milliseconds on common circuit
r
0
Surface: 2459-WPB-R Weatherproof Box
-45
Clear LEXAN with white marking sleeve
Strobe: 16-33 Vdc or Vfwr Continuous
45
UL min
Horn: 16-33 Vdc or Vfwr Continuous
15
-30
20
30
-15
15
0
98% relative humidity @ 40° C
30
40
style and optional markings.
45
60
2452THS-15/75-R
60
75
90
15 cd ceiling
15 cd wall
75 cd
75 cd
-90
-75
140 100
75 cd (-4A) Series Strobes
-60
-45
140
140
100
100
cd
60
60
-30
Horizontal Output
Average
Vertical Output
-90 -75
90
Not to be used for installation purposes.
-15
60
75
cd
-60
r
0
60
-45
45
UL min
15
60
-30
30
D A T A S H E E T
-15
15
30
0
100
45
60
140
75
90
Horizontal
-90
-75
90°
2452THS-110-R
110 cd (-8A) Series Strobes
-60
200
Horizontal
60 cd ceiling
-45
110 cd wall
150
100
150
100
50
cd
50
-30
110 cd
120 cd
S85001-0341
Horizontal Output
Average
100
90°
Vertical Output
-90 -75
-90°
90
-15
90°
Vertical
75
cd
-60
0
r
60
-90°
-45
45
UL min
-90°
15
-30
30
90°
100
-15
Vertical
15
30
0
45
Issue 6
60
200
75
90
-90°

Related parts for 2452THS-110-R