9-1393818-8 TE Connectivity, 9-1393818-8 Datasheet - Page 4

no-image

9-1393818-8

Manufacturer Part Number
9-1393818-8
Description
RELAY GP 4PDT 2A 20VDC
Manufacturer
TE Connectivity
Series
V23162, AXICOMr
Datasheet

Specifications of 9-1393818-8

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
2A
Switching Voltage
125VAC, 150VDC - Max
Coil Type
Non Latching
Coil Current
36.3mA
Coil Voltage
20VDC
Turn On Voltage (max)
17.7 VDC
Turn Off Voltage (min)
-
Features
Sealed - Hermetically
Mounting Type
Socketable
Termination Style
Plug In
Contact Material
Silver (Ag), Gold (Au)
Operate Time
7.5ms
Release Time
3ms
Coil Power
727 mW
Coil Resistance
550 Ohms
Operating Temperature
-40°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
V23162B720C110
4
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Dimensions
V23154-Mxxx, size I type
V23154-Nxxx, size II type
Instructions for Impulse Operation
The maximum voltage stated in the part code table can be increased for
impulse operation as follows:
U
U
q
The impulse voltage must not exceed 80% of the test voltage (winding/
frame or winding/winding) or 2.5 times the value of the maximum voltage
listed in the part code table.
Ift
value of q must be obtained from the nomograph.
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
tED = tI + tII
II Impuls
II tamb
ED
≤ 3s then q=
U
Maximum continuous voltage at ambient temperature t
Factor
II tamb
xq
; Ift
ED
= Pulse width, t
Signal Relays
Cradle N Relay V23154/V23162
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
2
= Cycle time. If t
tI + tII = Pulse widths
within one cycle
ED
amb
> 3s the
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
PCB layout
TOP view on component side of PCB
V23154-M/Nxx versions
M = Earth terminal
a) Hole for mechanical armature actuation, if required
b) Hole for socket mounting with screw M1.6.
(Continued)
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Axicom