3-1393808-1 TE Connectivity, 3-1393808-1 Datasheet
3-1393808-1
Specifications of 3-1393808-1
Related parts for 3-1393808-1
3-1393808-1 Summary of contents
Page 1
... Sockets for easy and quick mounting of relays n Typical applications Measurement and control equipment, control equipment in nuclear powerplant, press controls with high safety requirements (force-guided springs), telecommunications Contact Data Product code block 3 B104/B110/B112 Contact arrangement Max. switching voltage Rated current Limiting continuous current at max. ambient temperature Breaking capacity max ...
Page 2
... Coil data neutral 1.1 to 125 VDC, Terminals: coil with 1 winding: start 4, end 1 100 °C coil with 2 windings (upon request): < 50K/W start 3, end 2 for winding I, start 4, end 1 for winding II The minimum voltage U Coil Rated coil temperature, the maximum voltage U resistance power temperature. ...
Page 3
... A (6 NO) 4 form C (4 CO) V231xx-xxxxx-Bx12 V231xx-xxxxx-Bx10 V231xx-xxxxx-Cx12 Dimensions V23154-C0xx, size I type V23162-A0xx, size I type 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. ...
Page 4
... Factor The impulse voltage must not exceed 80% of the test voltage (winding/ frame or winding/winding) or 2.5 times the value of the maximum voltage listed in the part code table. Ift ≤ 3s then q= ; Ift = Pulse width value of q must be obtained from the nomograph. Examples of various periodic pulse trains (energizing side) 1 ...
Page 5
... V23154 types C0 Size I, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected (V23154) D0 Size II, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected (V23154) M0 Size I, for printed circuit mounting, with earth terminal, dust-protected (V23154) M4 ...
Page 6
... 6-1393806-3 6-1393806-9 7-1393806-0 7-1393806-5 8-1393806-2 8-1393806-3 1-1393806-3 9-1393806-1 9-1393806-2 1393807-2 1393807-3 1-1393807-1 1-1393807-2 1-1393807-5 4-1393806-8 1413000-2 1-1393807-7 4-1393806-0 2-1393808-8 3-1393808-0 3-1393808-1 3-1393808-3 3-1393808-4 3-1393808-5 3-1393808-8 3-1393808-9 4-1393808-0 4-1393808-3 4-1393808-5 4-1393808-6 3-1393807-0 4-1393808-9 5-1393808-0 8-1422029-2 5-1393808-3 5-1393808-6 5-1393808-7 6-1393808-1 1413000-3 7-1393807-5 7-1393807-8 ...
Page 7
... C (2 CO) 33VDC 22.6/54VDC 2 form C (2 CO) 33VDC 22.6/54VDC 2 form C (2 CO) 48VDC 23/75VDC 2 form C (2 CO) 48VDC 30/75VDC 2 form C (2 CO) 72VDC 36.2/114VDC 2 form C (2 CO) 125VDC 61/190VDC 2 form C (2 CO) 19VDC 8.2/31VDC 2 form A (2 NO) 24VDC 11/40VDC 2 form A (2 NO) 24VDC 11/40VDC 1A+1B 33VDC 16/54VDC 1A+1B ...
Page 8
... C (2 CO) 48VDC 30/75VDC 2 form C (2 CO) 72VDC 36/100VDC 2 form C (2 CO) 72VDC 36/100VDC 2 form C (2 CO) 72VDC 36.2/114VDC 2 form C (2 CO) 72VDC 36.2/114VDC 2 form C (2 CO) 72VDC 48.4/114VDC 2 form C (2 CO) 110VDC 65/164VDC 2 form C (2 CO) 125VDC 61/190VDC 2 form C (2 CO) 125VDC 81/190VDC 2 form C (2 CO) ...
Page 9
... A (2 NO) 24VDC 14.5/40VDC 1A+1B 33VDC 16/54VDC 2 form A (2 NO) 48VDC 30/75VDC 1A+1B 72VDC 48/100VDC 1A+1B 72VDC 36.2/114VDC 2 form A (2 NO) 72VDC 48.4/114VDC 1A+1B 125VDC 81/190VDC 1A+1B 7VDC 3.6/10.5VDC 4 form C (4 CO) 8.5VDC 7.6/14VDC 4 form C (4 CO) 10VDC 5.8/16.5VDC 4 form C (4 CO) 12VDC 7 ...
Page 10
... Signal Relays Cradle N Relay V23154/V23162 Product code Version V23162-H0XX, 5A, size II V23162-H0712-F104 5A, size II V23162-H0719-F104 5A, size II V23162-H0721-F104 5A, size II V23162-H0721-F107 5A, size II V23162-H0722-F104 5A, size II V23162-H0704-F104 5A, size II V23162-H0703-F104 5A, size II 10 09-2010, Rev. 0910 www.tycoelectronics.com © 2010 Tyco Electronics Ltd. (Continued) Coil Operate/Lim. Arrangement Contacts 7VDC 3.6/10.5VDC ...