G6KU-2F-RF-TR09DC12 Omron, G6KU-2F-RF-TR09DC12 Datasheet
G6KU-2F-RF-TR09DC12
Specifications of G6KU-2F-RF-TR09DC12
Related parts for G6KU-2F-RF-TR09DC12
G6KU-2F-RF-TR09DC12 Summary of contents
Page 1
... G6K-2F G6K-2F-Y G6K-2G G6K-2G-Y G6K-2P G6K-2P-Y Resistive load (cosφ=1) 0 125 VAC VDC Ag (Au clad 125 VAC, 60 VDC 1 A 37.5 VA, 30W 10 μ mVDC RC Single coil latching 3.2 mm coil-contact terminal spacing G6KU-2F-Y G6KU-2G-Y G6KU-2P-Y G6K 67 Low Signal Relay ...
Page 2
... G6KU- 3.2 mm spacing, single coil latching (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y) Rated voltage Rated current Coil resistance (VDC) (mA) (Ω) 3 33.0 91 4.5 23.2 194 5 21.1 237 6 17.6 341 9 11.3 795 12 9 ...
Page 3
... Note: The tests were conducted at an ambient temperature of 23°C. Ambient Temperature vs. Switching Current Ambient temperature (°C) Ambient Temperature vs. Must Set or Must Reset Voltage G6KU-2G (F/P)-Y Max. estimated value Ambient temperature (°C) Electrical Service Life (Contact Resistance) (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y NO ...
Page 4
... Not energized Average value Initial stage Test Sample Energized Average value (Average value) Sample: G6K-2G Must operate voltage Number of Relays: 10 Must release voltage External magnetic field (A/m) High-frequency Characteristics (Return Loss) G6K-2G (F/P),G6K-2G (F/P)-Y (Average value) 0 1.4 Sample: G6K-2G Number of Relays ...
Page 5
... Must Operate and Must Release Bounce Time Distribution (See note.) G6K-2G (F/P) , G6K-2G (F/P)-Y Must operate bounce time Must release bounce time Sample: G6K-2G Number of Relays: 50 Time (ms) Coil rating Contact ratings VDC (Resistive) 0 VDC (Resistive) 0 125 VAC (General Use) Mounting Dimensions (Top View) Tolerance: ±0.1 mm Mounting Dimensions (Top View) Tolerance: ± ...
Page 6
... Note: Each value has a tolerance of ±0.3 mm. G6K-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2G-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6K 72 Low Signal Relay Mounting Dimensions (Top View) Terminal Arrangement/ Internal Connections Tolerance: ± ...
Page 7
... Carrier tape Emboss tape 2. Reel Dimensions Stopper (green) 3. Carrier Tape Dimensions G6K-2F, G6K-2F-Y, G6KU-2F-Y Orientation mark Pulling direction G6K-2G, G6K-2G-Y, G6KU-2G-Y 50 pcs per anti-static tube 900 pcs per reel 2 reels per box Order in box multiples (see details below) G6K 73 Low Signal Relay ...
Page 8
... Time (s) • The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern. • In order to perform correct soldering recommended that the correct soldering conditions be maintained as shown below on the left side. Correct Soldering ...
Page 9
... Relay. PCB Mounting If two or more Relays are closely mounted with the long sides of the Relays facing each other and soldering is performed with infrared radiation, the solder may not be properly exposed to the infrared rays ...
Page 10
MEMO G6K 76 Low Signal Relay ...
Page 11
... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...
Page 12
... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...