G6L-1F-TRDC12 Omron, G6L-1F-TRDC12 Datasheet - Page 8

no-image

G6L-1F-TRDC12

Manufacturer Part Number
G6L-1F-TRDC12
Description
RELAY LOW SIGNAL SMD TR
Manufacturer
Omron
Series
G6Lr
Datasheet

Specifications of G6L-1F-TRDC12

Relay Type
Telecom
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
1A
Switching Voltage
125VAC, 60VDC - Max
Coil Type
Non Latching
Coil Current
15mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Features
Sealed - Fully
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
-
Operate Time
5ms
Release Time
5ms
Coil Power
180 mW
Coil Resistance
800 Ohms
Operating Temperature
-40°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6K 1116F
G6L1FTR12DC
G6L1FTRDC12
Precautions
■ Correct Use
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. Be sure to use a
fail-safe circuit design that provides protection against contact failure
or coil burnout.
Handling
Leave the Relays packed until just prior to mounting them.
Soldering
Solder: JIS Z3282, H63A
Soldering temperature: Approx. 250°C (At 260ºC if the DWS method
is used.)
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used.)
Be sure to adjust the level of the molten solder so that the solder will
not overflow onto the PCB.
Claw Securing Force During Automatic
Insertion
During automatic insertion of Relays, make sure to set the securing
force of the claws to the following values so that the Relay character-
istics will be maintained.
Environmental Conditions During Operation,
Storage, and Transportation
Protect the Relays from direct sunlight and keep the Relays under
normal temperature, humidity, and pressure.
44
Secure the claws to the area indicated by shading.
Do not attach them to the center area or to only part of the
Relay.
Low Signal Relay
A
Direction A: 5.0 N max.
Direction B: 5.0 N max.
Direction C: 5.0 N max.
C
G6L
B
Maximum Voltage
The maximum voltage of the coil can be obtained from the coil tem-
perature increase and the heat-resisting temperature of coil insulat-
ing sheath material. (Exceeding the heat-resisting temperature may
result in burning or short-circuiting). The maximum voltage also
involves important restrictions which include the following:
• Must not cause thermal changes in or deterioration of the insulating
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Therefore, be sure not to exceed the maximum voltage specified in
the catalog.
As a rule, the rated voltage must be applied to the coil. A voltage
exceeding the rated value, however, can be applied to the coil pro-
vided that the voltage is less than the maximum voltage. It must be
noted that continuous voltage application to the coil will cause a coil
temperature increase thus affecting characteristics such as electrical
life and resulting in the deterioration of coil insulation.
Coating
Relays mounted on PCBs may be coated or washed. Do not apply
silicone coating or detergent containing silicone, otherwise the sili-
cone coating or detergent may remain on the surface of the Relays.
Coil Power Supply Waveform
If the voltage applied to the coil is increased or decreased gradually,
operating characteristics may be unstable, contact endurance may
decline, or the Relay may not function at its full performance level.
Therefore, always use an instantaneous ON and instantaneous OFF
when applying the voltage. Be sure that the rated voltage or zero
voltage is reached within 1 ms.
material.