FLUKE-190-104/AM/S Fluke Electronics, FLUKE-190-104/AM/S Datasheet - Page 2

no-image

FLUKE-190-104/AM/S

Manufacturer Part Number
FLUKE-190-104/AM/S
Description
SCOPEMETER 4CH 100MHZ COLOR SCC
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-104/AM/S

Bandwidth
100MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
3.5nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1177
Oscilloscope Modes
2 Fluke Corporation
2 Fluke Corporation
Vertical deflection
Number of channels
Bandwidth
Rise time
Number of scope inputs
Channel architecture
Input coupling
Input sensitivity
Bandwidth limiter
Normal/invert/variable
Input voltage
Vertical resolution
Accuracy
Input impedance
Horizontal
Maximum real-time sample rate
(sampled simultaneously)
Record length
Time base range
Maximum record length
Timing accuracy
Glitch capture
Display and acquisition
Display
Display modes
Visible screen width
Digital persistence modes
Waveform mathematics
Acquisition modes
Trigger and delay
Source
Modes
Connect-and-View
Video triggering (on ch. A)
High-res, non-interlaced video
Pulse width triggering
(on channel A)
Time delay
Dual slope triggering
N-cycle triggering
ScopeMeter 190 Series II
ScopeMeter 190 Series II
625 MS/s for each
Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously
190-062
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
10 ns/div
to 4 s/div
channel
60 MHz
5.8 ns
Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
2
One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode
Slower time/division settings using ScopeRecord
Input A, B or External (via meter input)
2 input channels plus external trigger
CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatically displays stable waveforms of complex and dynamic signals like
30,000 points per channel in ScopeRecord
Automatic Connect-and-View
(using real time sampling and data compression, at any timebase setting)
Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,
± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
video, video line, selectable pulsewidth (channel A only), N-cycle
NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
1.25 GS/s for each
waveform compare with automatic “Pass/Fail testing”; Replay
All inputs fully insulated from each other and from ground
190-102
1 full screen of pre-trigger view or up to 100 screens
to 4 s/div
100 MHz
Any combination of channels; average on/off; replay
5 ns/div
channel
off/short/medium/long/infinite and envelope mode
User selectable: 20 kHz, 20 MHz or full bandwidth
3.5 ns
2 mV/div to 100 V/div, plus variable attenuation
153 mm (6 in) full-color LCD with LED backlight
Triggers on both rising and falling edges alike
2
10,000 samples per channel in scope mode;
Inputs may be activated in any combination
On each input channel, switched separately
adjusts triggering, time base and amplitude
12 divisions horizontally in scope mode
Frequency Spectrum using FFT analysis
(=1,200 divisions) of post-trigger delay
AC or DC, with ground level indicator
Up to 10,000 samples per channel
8 ns peak detect on each channel
Time base in a 1-2-4-sequence
± (0.01 % of reading + 1 pixel)
Can be switched off if preferred
motor drive and control signals
Pulse width qualified by time
1 MΩ ± 1 % // 14 pF ± 2 pF
, free run, single shot, edge, delay, dual slope,
2.5 GS/s (2ch)
190-202
to 4 s/div
200 MHz
2 ns/div
1.7 ns
8 bit
2
Roll mode (see ‘Recorder mode’)
Roll mode (see ‘Recorder mode’)
1.25 GS/s for each
190-104
to 4 s/div
100 MHz
5 ns/div
channel
3.5 ns
4
Input A, B, C or D
4 input channels
1.25 GS/s (4ch)
2.5 GS/s (2ch)
190-204
to 4 s/div
200 MHz
2 ns/div
1.7 ns
4