T3DDT0 GIC, T3DDT0 Datasheet - Page 53

TIME SWITCH, ASTRO, 3-PHASE CONTROL

T3DDT0

Manufacturer Part Number
T3DDT0
Description
TIME SWITCH, ASTRO, 3-PHASE CONTROL
Manufacturer
GIC
Datasheet

Specifications of T3DDT0

Contact Style
SPST
Contact Current Max
8A
Controller Output
Digital
Rohs Compliant
Yes
Frequency Monitoring Series PD 225
• Operable in various auxiliary supply voltage conditions &
• Models for Over Frequency and
• Monitors frequency of three signals - Sine, Square & Triangular
• Model for Frequency Limit Control: 5 Hz to 135 Hz
• Wide Signal Input Voltage: 15 to 500 VAC
52
Cat. No.
Parameters
Supply Voltage (Un):
Supply Variation
Power Consumption
Signal Type
Signal Input Voltage Range
Overall Frequency Range
Frequency Range Selection
Trip Level
Trip Levels
For Signal
Frequency
Response
Time
Relay Ouput
Contact Rating
Mechanical Life
Electrical Life
Contact Material
Utilization Category
Operating Temperature
Storage Temperature
Humidity (Non Condensing Limits)
LED Indications for Relay
LED Indications for UF & OF
Degree of Protection
Dimension (W x H x D)
Weight
Mounting
Certification
EMI/ EMC
Radio Interference Suppression
ESD
Electrical Fast Transients
Surges
Voltage Dips, Interruptions
Isolation
ORDERING INFORMATION
Cat. No.
MI81BJ
MI91BJ
MI81BL
MI91BL
frequency range by selecting proper model
Under/Over Frequency Monitoring
(%)
ON Delay
OFF Delay
Reset Time
Over Frequency
Under Frequency
Setting Accuracy
Repeat Accuracy
Reset Hysteresis
DC - 13
AC - 15
MI81BJ
110-240 VAC, 48-62 Hz
-15% to + 15% of Un
3 VA
Sinusoidal, Square, Triangular
(15 to 500) V
( 5 to 135) Hz
A
0
1
0
1
0.33 to 1 of Full Scale
N A
1.5 % of Full Scale selected
± 5%
± 0.02%
~ 500 ms
~ 500 ms
~ 150 ms
1 C/O (SPDT)
6A (Resistive) @ 240 VAC / 28 VDC
3 x 10 Operations
1 x 10 Operations
Ag alloy
Rated Voltage (Ue): - 120/240 V, Rated Current (Ie) :- 3/1.5 A
Rated Voltage (Ue): - 125/250 V, Rated Current (Ie) :- 0.22/0.1 A
- 20 C to + 80 C
- 15 C to + 60 C
Max. 95%
Terminals - IP 20, Housing - IP 40
22.5 X 83 X 100.5 (in mm)
120 g (unpacked)
Base / DIN rail
CIS
IE 61
IE
IE
IE
T
Description
110-240 V AC, Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O
220-440 V AC, Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O
110-240 V AC, Under/Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O
220-440 V AC, Under/Over
ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O
Red LED Flashing if No Signal
N A
est t bet e n nput & out t IE 609
C
C-61000-
C-61000-
C-61000-
o
o
PR 14-1
B
0
0
1
1
V g.
RoHS
6
5
Compliant
000-4-2 e l II
Frequency Range
(5 to 15) Hz
(15 to 45) Hz
(45 to 135) Hz
N A
4-4 e
4-5 e
4-1
Cl
w e i
o
o
ass B
1 A l 7 Leve s
L ve
L vel IV
L vel IV
l
l
Frequency
pu -
• Adjustable Relay status in healthy or
• Ease of Frequency setting with
• LED indications for healthy,
unhealthy condition using DIP switch "ET"
(Energize to Trip) or "DT" (De-energize to trip.)
simple Addition & Subtraction
unhealthy & no signal conditions
C
Monitoring Series PD 225 with
47-
5-1, 2
kV
MI91BL
220-440 VAC, 48-62 Hz
(40 to 70) Hz
50 Hz
60 Hz
(+ 1 to + 10) Hz
(- 1 to - 10) Hz
500 ms - 5 s
N A
Seperate Indications given for UF & OF Status

Related parts for T3DDT0