7P.20.1.000.9020 FINDER, 7P.20.1.000.9020 Datasheet

SPARK GAP MODULE

7P.20.1.000.9020

Manufacturer Part Number
7P.20.1.000.9020
Description
SPARK GAP MODULE
Manufacturer
FINDER
Datasheet

Specifications of 7P.20.1.000.9020

Current Rating
100mA
Supply Voltage
420VDC
No. Of Poles
1
Mounting Type
DIN Rail
Rohs Compliant
Yes
Svhc
No SVHC (20-Jun-2011)
Features
SPD Type 1+2 Surge arrester range - single phase
system / three phase system
7P.09.1.255.0100 SPD Type 1, GDT protection for
7P.01.8.260.1025 SPD Type 1+2, varistor
7P.02.8.260.1025 SPD Type 1+2 for single
7P.09 / 7P.01 / 7P.02
Screw terminal
For outline drawing see page 10
SPD specification
Nominal voltage (U
Maximum operating voltage (U
Lightning impulse current (10/350 μs) (I
Nominal discharge current (8/20 μs) (I
Maximum discharge current (8/20 μs) (I
Voltage protection level (U
Ability to independently switch off the
following current (I
Response time (t
Short-circuit proof at maximum overcurrent protection kA
Maximum overcurrent protection
Other technical data
Ambient temperature range
Protection degree
Wire size
Wire strip length
Screw torque
Remote status signalling contact specification
Contact configuration
Rated current
Rated voltage
Wire size (07P.01)
Approvals (according to type)
Surge arresters suitable in low-voltage applications
in order to protect equipment against overvoltage
by direct lightning strike, induction overvoltage
and switching overvoltage.
To be installed at the boundary of LPZ 0
zones or higher
Versions with combination of varistor and
encapsulated spark gap which eliminates leakage
current and ensures high discharge current
Remote status signalling contact for each
varistor module. Connector 07P.01 included
Visual fault signalling
According to EN 61 643-11
35 mm rail EN 60715 mounting, 35mm each pole
a
N-PE application only
unipolar protection suitable to
realize single phase or three
phase systems (230/400 V)
with the GDT protection (7P.09)
phase systrem. Varistor
protection L-N + spark gap
protection N-PE
)
fi
)
N
)
P
)
C
)
A AC/DC
V AC/DC
A
n
- LPZ 1
imp
)
max
AWG
AWG
V AC
V AC
) kA
mm
mm
Nm
)kA
mm
kA
kV
°C
rms
ns
A
2
2
SPD Type 1
Spark gap module for N-PE
application
7P.09.1.255.0100
100 (@255 V AC)
N-PE
255
100
100
100
100
1.5
1x 17...1x1
1x1...1x50
solid cable
7P Series - Surge Protection Device (SPD)
SPD Type 1+2
Combination of varistor and
encapsulated spark gap
Visual fault signalling varistor
status
solid cable
7P.01.8.260.1025
1.5
16
160 A gL/gG
No following
1 CO (SPDT)
–40...+80
0.5 - 0.1
current
IP20
230
260
100
250
1.5
25
30
60
35
14
4
stranded cable
1.5
16
160 A gL/gG
No following
stranded cable
SPD Type 1+2
Combination of varistor and
encapsulated spark gap +
spark gap
Visual fault signalling for
each varistor module
1x 17...1x2
1x1...1x35
solid cable
current
7P.02.8.260.1025
230
260
100
1.5
L-N
25
30
60
35
1.5
16
1 CO (SPDT)
0.5 - 0.1
250
stranded cable
N-PE
255
100
100
100
1.5
1.5
50
50
16
1

Related parts for 7P.20.1.000.9020

7P.20.1.000.9020 Summary of contents

Page 1

Features SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications • in order to protect equipment against overvoltage by direct lightning strike, induction overvoltage and switching overvoltage ...

Page 2

Features SPD Type 1+2 Surge arrester range - three phase system (230/400 V) Surge arresters suitable in low-voltage applications • in order to protect equipment against overvoltage by direct lightning strike, induction overvoltage and switching overvoltage installed at ...

Page 3

Features SPD Type 1 Surge arrester range with “Low U -System” – Single phase / three phase system p Surge arrester suitable for 230/400 V system/ • applications to prevent overvoltage effects caused by direct or indirect lightning strikes. To ...

Page 4

Features SPD Type 1 Surge arrester range with “Low U -System” – three phase system p Surge arrester suitable for 230/400 V system/ • applications to prevent overvoltage effects caused by direct or indirect lightning strikes installed at ...

Page 5

Features SPD Type 2 Surge arrester range - single phase systems Surge arrester suitable for 230V system/ • applications Protects equipment against overvoltage caused • by lightning strikes or switching transients To be installed at the boundary of LPZ 1-LPZ ...

Page 6

Features SPD Type 2 Surge arrester range - three-phase systems Surge arrester suitable for 230/400V • system/applications Protects equipment against overvoltage caused • by lightning strikes or switching transients To be installed at the boundary of LPZ 1-LPZ 2 • ...

Page 7

... A 200 V DC — 100 A 200 V DC 125 A gL/gG — 7P.20.9.350.0020 7P.20.1.000.9020 7P.20.9.350.0020 °C solid cable 2 1x1...1x50 1x 17...1x1 1 CO (SPDT) 0.5 - 0.1 250 solid cable stranded cable solid cable 2 1.5 1.5 1 7P.23.9.000.1020 SPD Type 2 (3 varistors) for • ...

Page 8

... Features SPD Type 3 Surge arrester for incorporation within socket outlets Provides easy additional surge protection for • existing 230 V sockets Protects electric and electronic equipment • against pulse overvoltage Combined varistor + spark-gap protection • (avoiding earth leakage current) Acoustical indication of varistor status • ...

Page 9

... Maximum discharge current (8/20 μs) (I Voltage protection level (U Response time ( Maximum overcurrent protection Replacement varistor and Spark-Gap modules 7P.20.8.275.0020 7P.20.9.350.0020 7P.20.9.500.0020 7P.20.1.000.0020 7P.20.1.000.9020 Maximum operating voltage (U Nominal discharge current (8/20 μs) (I Maximum discharge current (8/20 μs) (I Voltage protection level (U Response time (t ...

Page 10

Series - Surge Protection Device (SPD) - Dimensional data Type 7P.09 Screw terminal Type 7P.02 Screw terminal Type 7P.03 Screw terminal Type 7P.04 Screw terminal 10 Outline drawings Type 7P.01 Screw terminal ...

Page 11

Series - Surge Protection Device (SPD) - Dimensional data Type 7P.05 Screw terminal Type 7P.12 Screw terminal Type 7P.14 Screw terminal Type 7P.15 Screw terminal Outline drawings Type 7P.13 Screw terminal 11 ...

Page 12

Series - Surge Protection Device (SPD) - Dimensional data Type 7P.21 Screw terminal Type 7P.23.8 Screw terminal Type 7P.23.9 Screw terminal Type 7P.26 Screw terminal Type 7P.20 Replaceable module 12 Outline drawings Type 7P.22 Screw terminal Type 7P.24 Screw ...

Page 13

Installation example - SPD Type TT-SINGLE PHASE SYSTEM - SPD UP-STREAM OF RCD TT-THREE PHASE SYSTEM - SPD UP-STREAM OF RCD 7P Series - Surge Protection Device (SPD) TT-SINGLE PHASE SYSTEM - SPD UP-STREAM OF RCD TT ...

Page 14

Installation example for SPD Type 1 and Type 2 - Single phase TT-SINGLE PHASE SYSTEM - SPD UP-STREAM OF RCD Mandatory with LPS Note: suggested RCD type Series - Surge Protection Device (SPD TN-S SINGLE ...

Page 15

Installation example for SPD Type 1 and Type 2 - Three phase TT-THREE PHASE SYSTEM - SPD UP-STREAM OF RCD Mandatory with LPS TN-S THREE PHASE SYSTEM - SPD DOWN-STREAM OF OVERCURRENT PROTECTION 7P Series - Surge Protection Device (SPD) ...

Page 16

Installation examples - photovoltaic 16 7P Series - Surge Protection Device (SPD) ...

Page 17

... Figure 1: Ideal operation of an SPD SPD technologies Finder surge voltage protectors use either varistors or spark gaps. Varistor: this can be considered as a variable resistance that at nominal voltage has a very high ohmic value. But the resistance rapidly falls to near zero as the voltage surges. In this way the varistor applies a near short circuit which clamps the surge voltage ...

Page 18

... Finder SPD specified as 275 Voltage protection level: This is the highest voltage level seen across the SPD during its intervention. For example, for Finder SPD Type 2, this means that a 4kV overvoltage would be limited by the SPD to a maximum 1.2 kV. Consequently, electronic devices such as PC, TV, stereo, etc ...

Page 19

Protection against SPD’s short circuits is provided by the overcurrent protective devices (fuses type gL/gG) recomended. If the overcurrent protective devices F1 (which are part of the installation) have a rating smaller than or equal to the maximum recommended rating ...

Page 20

... LPS (with or without solar panels Series - Surge Protection Device (SPD) SPD fuse protection The Finder SPD can break a 100 A DC (@200 V DC) current. This means that for short circuit current of string (Isc) lower than 100 not necessary to install a back up fuse. = 420 V, ...

Related keywords