HAL 600-S LEM USA Inc, HAL 600-S Datasheet

no-image

HAL 600-S

Manufacturer Part Number
HAL 600-S
Description
SENSOR CURR 600A 3000V MOD
Manufacturer
LEM USA Inc
Series
HALr
Datasheet

Specifications of HAL 600-S

Current - Sensing
600A
Accuracy
±1%
Sensitivity
-
Current - Supply
±25mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
-15 V ~ 15 V
Output
±4V
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-25°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1102
110209/5
Current Transducer HAL 50..600-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
V
R
V
I
V
V
R
X
e
V
V
TCV
TCV
t
BW
T
T
m
Notes :
P
C
r
Primary nominal
A
S
OUT
C
b
d
L
OE
OM
L
is
current rms
Electrical data
Accuracy - Dynamic performance data
General data
100
200
300
400
500
600
I
PN
OE
OUT
50
(A)
Overload Capability (Ampere Turns)
Output voltage (Analog) @ ± I
Load resistance @ T
@ T
Supply voltage (± 5 %)
Current consumption
Rated isolation voltage rms
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 V
Accuracy @ I
Linearity error
Eletrical offset voltage @ T
Magnetic offset voltage @ I
after an overload of 3 x I
Temperature coefficient of V
Temperature coefficient of V
Response time to 90% of I
Frequency bandwidth (- 3 dB)
Ambient operating temperature
Ambient storage temperature
Mass
Standard
Deviation in output when tested to EN 61000-4-6
Deviation in output when tested to EN 61000-4-3
1)
2)
3)
4)
Overvoltage Category III, Pollution Degree 2
Excludes the electrical offset
Derating is needed to avoid excessive core heating at high frequency.
Please consult characterisation report for more technical details and
application advice.
4)
measuring range
PN
Primary current
2)
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
, T
± 150
± 300
± 600
± 900
± 1000
± 1000
± 1000
I
A
PM
= 25°C, ± 15 V
(A)
A
A
= - 25 .. + 85°C
= 0 .. + 70°C
PN
Safety
EMC
PN
A
1)
P
OE
OUT
step
DC
= 25°C HAL 50-S
4)
= 0,
3)
PN
( % of reading )
HAL 100..600-S < ± 10
HAL 50-S
HAL 100..200-S < ± 20
HAL 300..600-S < ± 10
HAL 50-S
HAL 100..600-S < ± 1.0
HAL 50-S
HAL 100-S
HAL 200-S
HAL 300-S
HAL 400-S
HAL 500-S
HAL 600-S
Type
app. 75
< ± 0.5
< ± 20
< ± 30
< ± 2.0
≤ ± 0.05
≤ 3
DC .. 50
- 25 .. + 85
- 25 .. + 85
EN 50178 :
EN50082-2:
EN50081-1:
< 20
< 20
< ± 1
30,000
± 4
> 1
> 3
± 15
< ± 25
500
3
> 500
RoHS since
date code
46180
46065
46090
46142
46114
46306
46059
% of I
% of I
% of I
mV/K
mV/K
1994
1992
1992
%/K
kHz
MΩ
mV
mV
mV
mV
mV
mA
kΩ
kΩ
kV
µs
°C
°C
%
PN
PN
PN
V
V
V
A
g
I
Features
Advantages
Applications
Application domain
PN
Galvanic isolation between primary
Hall effect measuring principle
and secondary circuit
Isolation voltage 3000V
Low power consumption
Extended measuring range(3 x I
Isolated plastic case recognized
according to UL 94-V0
Easy installation
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
AC variable speed drives
DC motor drives
Battery supplied applications
Uninterruptable Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Industrial
interference
= 50 .. 600 A
www.lem.com
Page 1/2
PN
)

Related parts for HAL 600-S

HAL 600-S Summary of contents

Page 1

... LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Type 4) HAL 50-S HAL 100-S HAL 200-S HAL 300-S HAL 400-S HAL 500-S HAL 600 < ± 1 < ± 0.5 = 25°C HAL 50-S < ± HAL 100..600-S < ± 10 ...

Page 2

Dimensions HAL 50..600-S Mechanical characteristics ● General tolerance ● Primary through-hole ● Connection of secondary Remarks ● positive when I flows in the direction of the arrow. OUT P ● Temperature of the primary conductor should not exceed ...

Related keywords