ZS-26-F SMC Corporation of America, ZS-26-F Datasheet

no-image

ZS-26-F

Manufacturer Part Number
ZS-26-F
Description
SENSOR CABLE 3M FOR PSE530/531
Manufacturer
SMC Corporation of America
Datasheet

Specifications of ZS-26-F

Accessory Type
*
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
*
Other names
606-1023
Option
When only optional parts are required, order using the part
numbers listed below.
Specifications
16-3-4
Rated pressure range
Proof pressure
Fluid
Power supply voltage
Current consumption
Output specification
Accuracy
Linearity
Repeatability
Power supply voltage effect
Temperature characteristics (Based on 25°C)
Port size
Material
Sensor cable/Option
Connector
Sensor cable
Connector +
Sensor cable
Description
Enclosure
Temperature range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Model
Pressure Sensor
Series
ZS-26-E
ZS-26-G
ZS-26-F
Part no.
0
1
2
3
Compound pressure [–101 to 101 kPa]
10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s
Pressure sensing range
The connector is not connected to
the cable at the time of shipment.
Low pressure [0 to 101 kPa]
High pressure [0 to 1 MPa]
Vacuum [0 to –101 kPa]
Cable length: 3 m
Cable length: 3 m
PSE530-M5
0 to 1 MPa
4 pcs. per set
1.5 MPa
PSE53 0
Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR
Note
±2% F.S. or less based on the analog output value at 25°C from a range of 0° to 50°C
±1% F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC
±2% F.S. or less (Within rated pressure range, Ambient temperature 25° ±3°C)
PSE530
1000 VAC, 50/60Hz for 1 minute between external terminals and case
0° to 50°C; Stored: –10° to 70°C (No freezing or condensation)
How to Order
Halogen-free heavy-duty cord, ø2.7, 0.15 mm
M5
980 m/s
Analog output (1 to 5 V, Output impedance: Approx. 1 kΩ)
5 MΩ between external terminals and case (at 50 VDC)
Port size
0 to –101 kPa
M5 x 0.8
PSE531-M5
2
in X, Y, Z directions, 3 times each (De-energized)
12 to 24 VDC (Ripple ±10% or less)
M5
Air/Non-corrosive gas
±1% F.S. or less
±1% F.S. or less
15 mA or less
M5 x 0.8
IP40
2
acceleration, in X, Y, Z directions, for 2 hours each (De-energized)
Note) At the factory, the connector is not connected to the
Option
Nil
CL
L
cable, but packed together with it for shipment.
PSE532-M5
0 to 101 kPa
Sensor cable (3 m)
Sensor cable (3 m) + Connector (1 pc.)
500kPa
2
, 3 cores, 3 m
Connector
Without cable
–101 to 101 kPa
PSE533-M5

Related parts for ZS-26-F

ZS-26-F Summary of contents

Page 1

... When only optional parts are required, order using the part numbers listed below. Description Part no. Connector ZS-26-E 4 pcs. per set Sensor cable ZS-26-F Cable length Cable length Connector + ZS-26-G The connector is not connected to Sensor cable the cable at the time of shipment. Specifications ...

Page 2

... Analog output ( Dimensions PSE53„-M5 3.4 With sensor cable Pressure Sensor Brown Black Blue Blue Black 29.4 0.5 27 5.5 PSE530 Series VDC Load M5 x 0.8 Pressure port 12 ZSE„ ISE„ PSE Z SE3 ZSP ISA2 IS„ ZSM PF2„ IF„ Data 16-3-5 ...

Page 3

... Enclosure “IP65” applies only to the front face of the panel when mounting. Do not use in an environment where oil splashing or spraying are anticipated. Handling 2 ) while handling. Although the body of Connection Operating Environment 16-3-19 ZSE„ ISE„ PSE Z SE3 ZSP ISA2 IS„ ZSM PF2„ IF„ Data ...

Page 4

... Wiring Caution 1. Connecting sensor cable and connector (ZS-26-E) • Cut the sensor cable as shown below. • Insert each lead wire into the corresponding connector number by following the chart provided below. Connector Core wire color no. ...

Page 5

... Pressure range that satisfies the product specifications (accuracy and linearity) for PSE530. Sensor part no. PSE510, PSE530 PSE521 PSE520 Brown 1 Black 2 Blue 3 N.C. 4 F.G. ) ZSE„ ISE„ PSE Z SE3 ZSP ISA2 IS„ ZSM PF2„ IF„ Data 16-3-21 ...

Page 6

Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 JIS ...

Page 7

Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. Selection Warning 1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), ...

Page 8

Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards “ISO 9001” and ...

Page 9

SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE ...

Page 10

Standards you to comply with EC directives and CSA/UL standards. í CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly ...

Page 11

... SMC’s Global Service Network America U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 MEXICO SMC Corporation (Mexico), S.A. DE C.V. ...

Page 12

Europe FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nijverheidsstraat 20 B-2160 ...

Related keywords