CB-OWS451I-04-0 ConnectBlue, CB-OWS451I-04-0 Datasheet - Page 25

RF SERIAL PORT ADAPTER INT ANT

CB-OWS451I-04-0

Manufacturer Part Number
CB-OWS451I-04-0
Description
RF SERIAL PORT ADAPTER INT ANT
Manufacturer
ConnectBlue
Series
CB-OWSr
Datasheets

Specifications of CB-OWS451I-04-0

Frequency
2.4GHz, 5GHz
Data Rate - Maximum
115 kbps
Modulation Or Protocol
802.11 a/b/g/n
Applications
General Purpose
Power - Output
20dBm (100mW)
Sensitivity
-89dBm
Voltage - Supply
3.3 V ~ 5.5 V
Current - Receiving
-
Current - Transmitting
-
Data Interface
Solder Pad
Memory Size
-
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Modular
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
809-1042
connectBlue
Copyright © 2010 connectBlue AB
Read this information before using your cB-OWL253 or cB-OWS451 module.
For any exceptions, due to national requirements or limitations, when using your cB-OWL253 or cB-OWS451 module, please contact
connectBlue AB.
The cB-OWL253 and cB-OWS451 module contains a small radio transmitter and receiver.
During communication with other WLAN products the cB-OWL253 and cB-OWS451 module receives and transmits radio frequency (RF)
electromagnetic fields (microwaves) in the frequency range 2412 - 2462 MHz and 5180 - 5240 MHz. The output power of the radio
transmitter is very low.
When using the cB-OWL253 or cB-OWS451 module, you will be exposed to some of the transmitted RF energy. This exposure is well
below the prescribed limits in all national and international RF safety standards and regulations.
Most modern electronic equipment, for example, in hospitals and cars, is shielded from RF energy. However, certain electronic
equipment is not. Therefore:
Turn off your electronic device before entering an area with potentially explosive atmosphere. It is rare, but your electronic device could
generate sparks. Sparks in such areas could cause an explosion or fire resulting in bodily injury or even death.
Areas with a potentially explosive atmosphere are often, but not always, clearly marked. They include fuelling areas, such as petrol
station, below deck on boats, fuel or chemical transfer or storage facilities, and areas where the air contains chemicals or particles, such
as grain, dust, or metal powders.
In order to fulfill the safety standard EN 60950-1:2006 the cB-OWL253 and cB-OWS451 must be supplied by a Class-2 Limited Power
Source.
8 Guidelines for efficient and safe use
8.1 General
8.2 Product care
8.3 Radio frequency exposure
8.4 Electronic equipment
8.5 Potentially explosive atmospheres
8.6 Safety compliance
8.6.1 Power supply
Do not expose your product to liquid or moisture.
Do not expose you product to extreme hot or cold temperature.
Do not expose your product to lit candles, cigarettes, cigars, open flames, etc.
Do not drop, throw or try to bend your product since rough treatment could damage your product.
Do not attempt to disassemble your product. Doing so will void warranty. The product does not contain consumer serviceable or
replaceable components. Service should only be performed by connectBlue AB.
Do not paint your product as the paint could prevent normal use.
If you will not be using your product for a while, store it in a place that is dry, free from
damp, dust and extreme heat and cold.
The clearance and creepage distances required by the end product must be withheld when the module is installed.
The cooling of the end product shall not negatively be influenced by the installation of the module when the module is installed.
Connect your power supply only to designated power-sources as marked on the product.
Make sure all cords and cable are positioned so that they will not be stepped on, tripped over or otherwise subject to damage or
stress.
To reduce risk of electric shock, unplug the unit from any power source before attempting to clean it.
Changes or modifications to the product not expressly approved by connectBlue AB will void the user's authority to
operate the equipment.
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Please insure that all medical devices
used in proximity to this device meet appropriate susceptibility specifications for this type of RF energy.