EDK300 Summary of contents

Page 1

Getting Started V1.5 ...

Page 2

... EnOcean will not be reliable for consequences of any changes/modifications of the developer board(s) done by the developer. Before using EDK 300 please consider country specific radio regulations and frequencies, e.g. R& ...

Page 3

Index 1 Introduction ..............................................................................................4 2 Line-powered applications with EVA 300 and TCM 3x0 ..............................5 2.1 Overview ................................................................................................. 5 2.2 Default Configuration ................................................................................ 6 2.3 Example: „1-Channel Relay Switch‟ (Mode 2) ................................................ 7 2.4 Example: „1-Channel Dimmer‟ (Mode 4) ...................................................... 8 ...

Page 4

... Additional developer kits are available for self-powered radio nodes of the STM 3xy product family:  EDK 310 (Solar powered STM 3xy)  EDK 312 (Thermo powered STM 3xy) Page 4/24 TCM 320 TCM 3x0 EDK 300 Developer‟s Kit © EnOcean GmbH ...

Page 5

Line-powered applications with EVA 300 and TCM 3x0 2.1 Overview EOP 300 Programmer LED: Power EOP VCCUSB LED: Power EVA VCCIO LED: Programmer PROGACTIVE TCM 3x0 Repeater config. TCM 3x0 Mode config. V1.5 05/2011 EVA 300 Board Power ON/OFF ...

Page 6

... Clear: clear whole ID list (standard TCM 3x0 FW) LEDs:  IO indicators  PWM (dimmer) or RSSI (signal strength) Modul & extension slots:  TCM 300 adapter board connector  TCM 320 connector Page 6/24 USB power supply TCM 300 optional / not equipped © EnOcean GmbH ...

Page 7

... Switching PTM 2x0 will toggle CH0 LED (relay pin) Attention:  If you have changed TCM firmware: Load EnOcean TCM 300 default firmware from CD  If you have changed mode settings: Clear ID - press CLEAR button > 2s (LEDs “LMI” will light & “CH0” blink) - press RESET (mode selection) V1 ...

Page 8

... PWM value - press 0-side short time, TCM3x0 will switch off Attention:  If you have changed FW: Load EnOcean TCM 300 default firmware from CD  If you have changed mode settings: Clear ID - press CLEAR button > 2s (LEDs “LMI” will light & “CH0” blink) ...

Page 9

... DolphinView  Visualize properites of EnOcean radio nodes  Receives, sends and analyses radio telegrams according to the EnOcean standard  Get detailed information e.g. subtelegram timing and signal strength  Content of telegrams can be analyzed online and logged with time stamp  ...

Page 10

... Attention:  If you have installed a previous DolphinStudio version recommended to uninstall older version  If you have already installed older FTDI USB driver recommended to remove previous and install latest FTDI driver by cross marking installation menu at the end of DolphinSetup Page 10/ © EnOcean GmbH ...

Page 11

Check FW Version with DolphinStudio 1. Connect EVA 300 or EVA 320 with STM/TCM 3x0 plugged via EOP 300 Launch DolphinStudio 3. Select “EOPX (Program- mer)” tab 4. Select “Chip information” 5. Press “Retrieve” button 6. ...

Page 12

... Connect EVA 300 or EVA 320 with STM/TCM 3x0 plugged via EOP 300 Launch DolphinStudio 3. Select “EOPX (Programmer)” tab 4. Select “Programmer” 5. Select FW file via “Browse…” button; chip configuration file will be automatically recognized by ending *cfg.hex 6. Press “Execute” button to start the update process Page 12/ © EnOcean GmbH ...

Page 13

... Configure STM 300 module STM 300 is designed for multiple applications, therefore no application specific EnOcean Equipment Profile (EEP) is implemented. To use the auto learn function in DolphinView (or other EnOcean devices), the EEP profile must be configured first with DolphinStudio Start Dolphin Studio and select „Chip configuration‟ ...

Page 14

... ESP2+EPM: internal use - ESP3: TCM 300/320 incl. gateway controller firmware 5. Connect to EVA 300 board (= transceiver) 6. Check connection via EVA 300 transceiver example (see next page EnOcean Serial Protocol ** Future DolphinView versions will automatically select the serial protocol type Page 14/ © EnOcean GmbH ...

Page 15

Example ‘EVA 300 as Transceiver’ (Mode 1) EVA 300 configured as transceiver (Mode 1): 1. Check jumper configuration and TCM 300 module according to the picture on the right side 2. Connect EVA 300 via EOP 300 to PC ...

Page 16

... Now it‟s possible to set up manually the EEP* Profile in the tab EEP View, e.g. for the RPS telegram 8. Subsequently the node button shows the label „EEP has been selected‟ 9. The tab EEP View indicate the complete EEP profile details * EnOcean Equipment Profile Details see: http://www.enocean-alliance.org/ Page 16/ © ...

Page 17

Self-powered Applications with EVA 320 and STM 300 4.1 Overview EOP 300 Programmer LED: Power EOP VCCUSB LED: Power EVA VCCIO LED Programmer: PROGACTIVE Power ON/OFF switch STM 300 on adapter board STM 300 config. LED: Radio send STM ...

Page 18

... Wake up & retransmit STM 300 standard FW:  Wake Up (1s/10s/100s/None)  Retransmit (7-14/70-140/None) Buttons:  Reset  Button1  Button2  WAKE1/Learn  WAKE0/Occupancy Modul & extension slots:  STM 300 on adapter board  Optional Power Converter Page 18/24 © EnOcean GmbH ...

Page 19

Example: ‘Self-powered temperature sensor’ EVA 320 as temperature sensor, DolphinView to monitor radio with EVA300 as receiver: 1. Set EVA 320 jumper configuration according to the image right side: - retransmit = every - wakeup = 10s - storage ...

Page 20

... Select tab “EEP View” Selected device with Chip ID & EEP ID-label Manufacturer ID & EEP profile no. Attention:  EVA320 needs sufficient energy (e.g. light) to transfer radio telegrams Page 20/24 DB1 (data byte 1) = temperature value (for details see 4BS telegram EnOcean Equipment Profile) © EnOcean GmbH ...

Page 21

Example: ‘Self-powered room operating panel’ EVA 320 as room operating panel and Dol- phinView to monitor radio with EVA 300 as receiver: Configure EVA 320: 1. Set EVA 320 jumper configuration according to the image right side: - retransmit ...

Page 22

... EDK 300 Getting Started Sensor values can be visualized by using DolphinView: 1. Start DolphinView and select the tab „EEP View‟ 2. Select the node 3. Diagram will show received temperature sensor and „Set Point‟ potentiometer values Page 22/24 © EnOcean GmbH ...

Page 23

...

Related keywords