S8VS-18024BE Omron, S8VS-18024BE Datasheet - Page 33

no-image

S8VS-18024BE

Manufacturer Part Number
S8VS-18024BE
Description
POWER SPLY SW 100-240VAC 7.5A
Manufacturer
Omron
Series
S8VSr
Datasheet

Specifications of S8VS-18024BE

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
180W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
24 VDC @ 7.5A
2nd Output
-
3rd Output
-
4th Output
-
Size / Dimension
4.93" L x 2.95" W x 4.53" H (125mm x 75mm x 115mm)
Operating Temperature
-10°C ~ 60°C
Power (watts) - Max
180W
Efficiency
80%
Approvals
CE, CSA, cUL, EN, UL, VDE
Line Regulation
-
Load Regulation
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VS18024BE
Z3187
Output Voltage Adjuster (V.ADJ)
15-W, 30-W Models
60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models
DIN Rail Mounting
To mount the Block on a DIN Rail, hook portion (A) of the Block onto
the rail and press the Block in direction (B).
To dismount the Block, pull down portion (C) with a flat-blade
screwdriver and pull out the Block.
Series Operation
(24-V Model)
Two power supplies can be connected in series.
Note: 1. The diode is connected as shown in the figure. If the load is
• The output voltage adjuster (V.ADJ) may possibly be damaged if it
• After completing output voltage adjustment, be sure that the output
• If the output voltage is set to a value less than −10%, the
• If the detection voltage of the undervoltage alarm function is at the
Dielectric strength (V
Forward current (I
is turned with unnecessary force. Do not turn the adjuster with
excessive force.
capacity or output current does not exceed the rated output
capacity or rated output current.
undervoltage alarm function may operate.
factory setting and the output voltage is set to a value of 20 V or
less, the undervoltage alarm function may operate.
2. Although Products having different specifications can be
3. Serial operation is not possible with 5-V and 12-V models.
short-circuited, a reverse voltage will be generated inside
the Power Supply. If this occurs the Power Supply may
possibly deteriorate or be damaged. Always connect a
diode as shown in the figure.
Select a diode having the following ratings.
connected in series, the current flowing through the load
must not exceed the smaller rated output current.
Type
Correct
F
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
30 mm min.
)
RRM
(A)
Track stopper
) Twice the rated output voltage or above
AC (N)
AC (N)
AC (L)
AC (L)
Twice the rated output current or above
(B)
In the interest of product improvement, specifications are subject to change without notice.
(C)
Schottky Barrier diode
+V
−V
+V
−V
Parallel Operation
The Product is not designed for parallel operation.
In Case There Is No Output Voltage
The possible cause for no output voltage may be that the overcurrent
or overvoltage protection has operated. The internal protection may
operate if a large amount of surge voltage such as a lightening surge
occurs while turning ON the power supply.
In case there is no output voltage, please check the following points
before contacting us:
Buzzing Noise When the Input Is Turned ON
(120-W, 180-W, 240-W, and 480-W Models)
A harmonic current suppression circuit is built into the Power Supply.
This circuit can create noise when the input is turned ON, but it will
last only until the internal circuits stabilize and does not indicate any
problem in the Product.
• Checking overload protected status:
• Checking overvoltage or internal protection (except for 15-W
Check whether the load is in overload status or is short-circuited.
Remove wires to load when checking.
models):
Turn the power supply OFF once, and leave it OFF for at least
3 minutes. Then turn it ON again to see if this clears the condition.
Incorrect
AC (N)
AC (N)
AC (L)
AC (L)
+V
−V
+V
−V
S8VS
33

Related parts for S8VS-18024BE