NL1-C ANTENNA Omron, NL1-C ANTENNA Datasheet - Page 5

no-image

NL1-C ANTENNA

Manufacturer Part Number
NL1-C ANTENNA
Description
Basic / Snap Action / Limit Switches HEAD FOR NL1-C AND NL3-C
Manufacturer
Omron
Series
NLr
Datasheet

Specifications of NL1-C ANTENNA

Lead Free Status / Rohs Status
No
Dimensions
Built-in Antenna Models
Coil Spring
NL1-C
NL2-C
NL3-C
Note: 1. The force that pushes the actuator must not exceed 1.96 N.
Separated Antenna Models
The dimensions provided for the NL1-SP, NL2-SP, NL1-SC, and NL2-SC are the external dimensions for the antennas. The casing
dimensions of these models are all the same as those for the coil spring or plunger models.
No Antenna
NL1-S
NL2-S
Note: 1. Make sure that the shape of the antenna is suitable to the application.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The antenna is replaceable. Contact your OMRON representative for
2. Do not cut or extend the connecting cable.
details.
Use the plunger antenna or coil spring antenna as shown right for the
NL1-S or NL2-S.
(95)
110
*1. The coil spring antenna is movable in any direction. Make sure
*2. Use after removing the caution label.
(27)
7-dia. Connection
cable (1 m)
2
that the angle of the antenna is within 30 to the FP (free position)
after the antenna comes into contact with the object.
7-dia. Connection
cable (1 m)
55
25 max.
*1. A standard 3-m high-frequency coaxial cable is provided.
*2. Use after removing the caution label.
12.5
75
25 max.
75
60
1
8
60
0.2
5
1
8
0.2
5
(15)
40
30
0.8
40
0.2
15
30
7 dia. *1
0.2
0.8
15
1.2 dia. *1
Caution label
6.5
5.3 dia.
Two, 5.3-dia.
long holes
(7.3)
Two,
5.3
holes
Two, 5.3-dia.
long holes
(7.3)
Caution label
Two,
5.3
holes
0.8
0.12
LED operation
indicator
LED operation
indicator
0.12
dia.
*2
dia.
*2
25.8
43.7
43.7
30
30
0.8
0.8
16
16
15
15
Plunger
NL1-P
NL2-P
NL3-P
Note: Do not apply a force greater than 9.8 N to the plunger.
Plunger Antenna
NL1-SP
NL2-SP
(
Note: 1. Do not apply a force greater than 9.8 N to the plunger.
Coil Spring Antenna
NL1-SC
NL2-SC
*2
Note: 1. Do not cut or extend the connecting cable.
Two, M22 x 1
mounting nuts
Distance to
opposite side: 26
thickness: 4
(10.5)
(10.5)
2. Do not cut or extend the connecting cable.
2. The antenna is replaceable. Contact your OMRON representative for
*3
8
details.
)
22.5
8
31
12
20
22.5
6
31
35
(2.3R)
t 2.3
(99)
3.5
6
90.5
*1. The stainless-steel plunger antenna allows a maximum
*2. This position is the FP (free position) of the plunger.
*3. Use after removing the caution label.
1.2 dia. *1
5 *2
4.5
7-dia. Connection
cable (1 m)
31
OT (overtravel) of 5 mm.
6 dia.
40.5
2
*1
25 max.
12.5
16
2
75
16
32
0.2
60
5 *2
8
0.2
1
R16
5
35
40
0.5
30
+0.8
+0.2
*1. The coil spring antenna is movable in any
*2. A standard 3-m high-frequency coaxial
15
51
direction. Make sure that the angle of the
antenna is within 30 to the FP (free position)
after the antenna comes into contact with the
object.
cable is provided.
6 dia. *1
*1. The stainless-steel plunger antenna
*2. This position is the FP
*3. A standard 3-m high-frequency
Two, 5.3-dia.
long holes
(7.3)
Caution label
Two,
5.3
holes
allows a maximum OT (overtravel)
of 5 mm.
(free position) of the plunger.
coaxial cable is provided.
0.12
dia.
*3
(Unit: mm)
43.7
30
+0.8
16
15
NL
5

Related parts for NL1-C ANTENNA