LA 55-P LEM, LA 55-P Datasheet - Page 3

CURRENT SENSOR

LA 55-P

Manufacturer Part Number
LA 55-P
Description
CURRENT SENSOR
Manufacturer
LEM
Datasheet

Specifications of LA 55-P

Current Measuring Range Ac
± 70A
Current Measuring Range Dc
± 70A
Sensor Output
Closed Loop
Accuracy
± 0.65%
Response Time
1µs
Rohs Compliant
Yes
Accuracy %
0.65%
Dimensions LA 55-P
Mechanical characteristics
090519/14
Front view
Top view
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
(in mm. 1 mm = 0.0394 inch)
± 0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56 mm
0.9 mm
Remarks
I
Temperature of the primary conductor should not exceed
90°C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
In order to achieve the best magnetic coupling, the
primary windings have to be wound over the top edge of
the device.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
S
is positive when I
P
flows in the direction of the arrow.
Connection
www.lem.com
Left view
Page 3/3