LM2506SQ/NOPB National Semiconductor, LM2506SQ/NOPB Datasheet - Page 14

IC SER/DESER 18BIT MPL 4O-LLP

LM2506SQ/NOPB

Manufacturer Part Number
LM2506SQ/NOPB
Description
IC SER/DESER 18BIT MPL 4O-LLP
Manufacturer
National Semiconductor
Series
LMr
Datasheet

Specifications of LM2506SQ/NOPB

Function
Serializer/Deserializer
Data Rate
320Mbps
Input Type
LVCMOS
Output Type
LVCMOS
Number Of Inputs
22
Number Of Outputs
3
Voltage - Supply
1.74 V ~ 3 V
Operating Temperature
-30°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-LLP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM2506SQTR
www.national.com
Application Information
Power and Ground - Bumped Package
Power and ground bump assignments are shown in Figure
15. The nine center balls must be connected ground on the
FLEX CIRCUIT RECOMMENDATIONS
The three MPL lines should generally run together to mini-
mize any trace length differences (skew). For impedance
control and also noise isolation (crosstalk), guard ground
traces are recommended in between the signals. Commonly
a Ground-Signal-Ground (GSGSGSG) layout is used. Lo-
cate fast edge rate and large swing signals further away to
also minimize any coupling (unwanted crosstalk). In a
stacked flex interconnect, crosstalk also needs to be taken
into account in the above and below layers (vertical direc-
tion). To minimize any coupling locate MPL traces next to a
ground layer. Power rails also tend to generate less noise
than LVCMOS so they are also good candidates for use as
isolation and separation.
The interconnect from the SER to the DES typically acts like
a transmission line. Thus impedance control and ground
returns are an important part of system design. Impedance
should be in the 50 to 100 Ohm nominal range for the
LM2506. Testing has been done with cables ranging from 40
to 110 Ohms without error (BER Testing). To obtain the
impedance, adjacent grounds are typically required ( 1 layer
flex), or a ground shield / layer. Total interconnect length is
intended to be in the 20cm range, however 30cm is possible
at lower data rates. Skew should be less than 500ps to
maximize timing margins.
GROUNDING
While the LM2506 employs three separate types of ground
pins, these are intended to be connected together to a
FIGURE 15. LM2506 PWR (V
(Continued)
DD
) and GND (V
14
PCB for the microArray package. See also, National’s Appli-
cation Note AN-1126, Ball Grid Array, for information on land
pattern recommendations and escape routing guidelines.
common ground plane. The separate ground pins help to
isolate switching currents from different sections of the inte-
grated circuit (IC). Also required is a nearby signal return
(ground) for the MPL signals. These should be provided next
to the MPL signals, as that will create the smallest current
loop area. The grounds are also useful for noise isolation
and impedance control.
PCB RECOMMENDATIONS
General guidelines for the PCB design:
• Floor plan – locate MPL SER near the connector to limit
• Route serial traces together, minimize the number of
• Use ground lines are guards to minimize any noise cou-
• Avoid parallel runs with fast edge, large LVCMOS swings.
• Also use a GSGSG pinout in connectors (Board to Board
• DES device - follow similar guidelines.
• Bypass the device with MLC surface mount devices and
• High current returns should have a separate path with a
chance of cross talk to high speed serial signals.
layer changes to reduce loading.
pling (guarantees distance).
or ZIF).
thinly separated power and ground planes with low induc-
tance feeds.
width proportional to the amount of current carried to
minimize any resulting IR effects.
SS
) Bumps (TOP VIEW)
20125521