A5348
ELECTRICAL CHARACTERISTICS
R
The A5348 is a low-current, BiCMOS circuit providing all of the
required features for an ionization-type smoke detector.
Oscillator
An internal oscillator operates with a period of 1.67 seconds
during no-smoke conditions. Every 1.67 seconds, internal power
is applied to the entire circuit for 10 ms and a check is made for
smoke. Every 24 clock cycles (approximately 40 seconds), the
LED pin is pulsed and a check is made for low battery by com-
paring V
are used in the device, the oscillator capacitor at the OSC CAP
pin should be a low-leakage type (PTFE, polystyrene, or polypro-
pylene).
Detector Circuitry
When the voltage on the DETECT IN pin is less than the volt-
age on the SENSITIVITY SET pin, the A5348 evaluates this as a
smoke condition. During a smoke condition, the resistor divider
network that sets the sensitivity (also referred to as the smoke trip
point) is altered to increase V
(with no external connections on the SENSITIVITY SET pin).
This provides hysteresis and reduces false triggering.
An active guard is provided on GUARD1 and GUARD2, the two
pins adjacent to the detector input, the DETECT IN pin. V
and V
keep surface leakage currents to a minimum and provide a
method of measuring the input voltage without loading the ion-
ization chamber. The active guard amplifier is not power strobed
and thus provides constant protection from surface leakage
I/O Current
I/O Alarm Voltage
I/O Delay
1
2
Negative current is defi ned as coming out of the specifi ed device pin (sourcing).
Alarm (smoke) condition is defi ned as V
TIMINGRES
GUARD2
Characteristic
DD
to an internal reference. Because very-low currents
= 8.2 MΩ (unless otherwise noted)
will be within 100 mV of V
SENSITIVITYSET
Symbol
V
I
t
I
IH(IO)
IOH
r(io)
IOL
DETECTIN
No alarm, V
Local alarm, V
External “alarm” in
Local or test alarm to I/O active
1,2
DETECTIN
(continued) at T
< V
by 130 mV typical
Test Conditions
SENSITIVITYSET
I/O
. This will
I/O
= V
Circuit Description
= V
DD
GUARD1
DD
– 2.0 V
; no alarm (no smoke) condition is defi ned as V
A
– 2.0 V
= 25°C, V
currents. The detector input has internal diode protection against
electrostatic damage.
Alarm Circuitry
If smoke is detected, the oscillator period changes to 40 ms and
the horn is enabled. The horn output is typically 160 ms on,
80 ms off. During the off-time, smoke is checked and further
alarm output will be inhibited if smoke is not sensed. During a
smoke condition, the low-battery alarm is inhibited and the LED
is pulsed approximately once every second.
Sensitivity Adjust
The detector sensitivity to smoke is set internally by a voltage
divider connected between VDD and VSS. The sensitivity can,
however, be externally adjusted to the individual characteristics
of the ionization chamber by connecting a resistor between the
SENSITIVITY SET pin and either the VDD or VSS pins.
With no external connections on the SENSITIVITY SET pin,
while the A5348 is checking for smoke:
To increase sensitivity, a resistor can be connected between
SENSITIVITY SET and VDD, with the value:
where
To decrease sensitivity, a resistor can be connected between
Test Pin
DD
2
2
2
2
with Interconnect and Timer
= 9.0 V, V
Ionization Smoke Detector
R
SENSITIVITYSET
K = V
Min.
–7.5
V
SS
3.0
25
SENSITIVITYSET
= 0 V, C
DD
/ V
115 Northeast Cutoff
1.508.853.5000; www.allegromicro.com
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 U.S.A.
SENSITIVITYSET
= 1.1E6 × K / (1 – K) ,
OSCCAP
Typ.
DETECTIN
3.0
= V
= 0.1 μF,
DD
> V
/ 2 .
SENSITIVITYSET
– 1 .
Max.
60
.
Units
mA
μA
V
s
5