7-215083-6 TE Connectivity, 7-215083-6 Datasheet - Page 15

CON MICROMATCH 6 WAY RIBBION MALE

7-215083-6

Manufacturer Part Number
7-215083-6
Description
CON MICROMATCH 6 WAY RIBBION MALE
Manufacturer
TE Connectivity
Series
Micro-Match Seriesr
Datasheets

Specifications of 7-215083-6

Product Type
Plugs - Housings
Contact Gender
Pin (Male)
Pitch
1.27 mm
Number Of Positions / Contacts
6
Number Of Rows
2
Row Spacing
1.5 mm
Mounting Style
Free Hanging
Mounting Angle
Right
Latching Type
Unlatched
Termination Style
Cable
Wire Type
Ribbon
Housing Material
Thermoplastic Polyester, Glass Filled
Contact Material
Phosphor Bronze
Contact Plating
Tin over Nickel
Voltage Rating
230 V
Current Rating
1.5 A
Type Of Connector
Male-On-Wire
Wire/cable Type
Ribbon Cable
Insulation Diameter (mm [in])
0.90 [.035]
Polarization
Without
Number Of Positions
6
Wire Range (mm [awg])
0.08-0.09² [28]
Centerline (mm [in])
1.27 [0.050]
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Tin
Housing Color
Red
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Cable
Packaging Method
Box
Packaging Quantity
250
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
7-215083-6
Manufacturer:
TE
Quantity:
20 000
Part Number:
7-215083-6
Manufacturer:
TE
Quantity:
35 000
.
QUALITY ASSURANCE PROVISIONS
4.1
4.1.1
Samples shall be released in accordance with applicable instruction sheets. They shall be selected at
random from production. At least 5 connectors of the 6 positions or at least 30 contacts shall be used for
each testgroup.
4.1.2
Qualification inspection shall be verified by testing samples as specified in spec. 108-19052 Par 3.7.
4.2
If changes significantly affecting form, fit or function are made to the product or the manufacturing
process, product assurance shall co-ordinate requalification testing, consisting of all or part of the original
testing sequence as determined by development/product, quality and reliability engineering.
4.3
Acceptance is based on verification that the product meets the requirement of par 3.6. Failures attributed
to equipment, test set-up or operator deficiencies shall nor disqualify the product. When product failure
occurs, corrective action shall be taken and samples resubmitted to qualification. Testing to confirm
corrective action is required before submittal.
4.4
The applicable AMP quality inspection plan will specify the samples acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with applicable product drawing and this
specification.
Rev. F
R6-77 (Rev. 07-01)
Sample selection:
Test sequence
Qualification testing:
Requalification testing
Acceptance.
Quality Conformance Inspection
Page 15 of 15