AT42QT1111-MU Atmel, AT42QT1111-MU Datasheet - Page 31

no-image

AT42QT1111-MU

Manufacturer Part Number
AT42QT1111-MU
Description
IC TOUCH SENSOR 11KEY QFN
Manufacturer
Atmel
Series
QTouch™r
Type
Capacitiver
Datasheet

Specifications of AT42QT1111-MU

Touch Panel Interface
10, 2-Wire
Number Of Inputs/keys
11 Key
Data Interface
Serial, SPI™
Voltage Reference
Internal
Voltage - Supply
3 V ~ 5.5 V
Current - Supply
12mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
32-VFQFN Exposed Pad
Output Type
Logic
Interface
SPI
Input Type
Logic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
AT42QT1111-MU
AT42QT1111-MUTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT42QT1111-MU
Manufacturer:
Atmel
Quantity:
4 694
7.6
7.7
9571A–AT42–02/10
Address 2: Detect Integrator Limit (DIL)/Drift Hold Time (DHT)
Address 3: Positive Threshold (PTHR)/Positive Hysteresis (PHYST)
Where data is being sent by the host, a 1-byte CRC should be sent. The QT1111 returns the
expected CRC byte in the same transaction the CRC byte is sent. In this way, the host can
immediately determine whether the setup data bytes were received correctly.
Default GUARD_KEY value:
Default GD_EN value:
Default CHG value:
Default CRC value:
Table 7-5.
DIL: the detection integrator (DI) limit. To suppress false detections caused by spurious events
like electrical noise, the device incorporates a DI counter mechanism. A per-key counter is
incremented each time the channel has exceeded its threshold and stayed there for a number of
acquisitions in succession, without going below the threshold level. When this counter reaches a
preset limit the channel is finally declared to be touched. If on any acquisition the delta is not
seen to exceed the threshold level, the counter is cleared and the process has to start from the
beginning.
Note:
DHT: the drift hold time. After a key-touch has been removed, the QT1111 pauses in the
implementation of its “Drift” compensation for a time. After this time has expired, drift
compensation continues as normal. The “Drift Hold Time” is a multiple of 160 ms, providing
options from 0 to 2400 ms.
Default DIL value:
Default DHT value:
Table 7-6.
PTHR: the positive threshold for the signal. If a key signal is significantly higher than the
reference signal, this typically indicates that the calibration data is no longer valid. In other
words, some factor has changed since the calibration was carried out, thus rendering it invalid.
Generally this is compensated for by the drift, but the greater the difference the longer this will
take. In order to speed up this correction, the positive threshold is used: if the positive threshold
is exceeded, the QT1111 (that is, all keys) is recalibrated.
Address
Address
2
3
A setting of 0 for DI is invalid; the valid range is 1 to 15.
Bit 7
Bit 7
Detect Integrator/Drift Hold Time
Positive Threshold (THR)/Positive Hystereis (HYST)
Bit 6
Bit 6
AT42QT1111-MU/AT42QT1111-AU
DIL
Bit 5
Bit 5
0 (Key 0)
0 (disabled)
0 (data mode)
0 (disabled)
3
8 (1280 ms)
PTHR
Bit 4
Bit 4
Bit 3
Bit 3
Bit 2
Bit 2
DHT
Bit 1
Bit 1
PHYST
Bit 0
Bit 0
31

Related parts for AT42QT1111-MU