SI2457-C-FT Silicon Laboratories Inc, SI2457-C-FT Datasheet - Page 26

no-image

SI2457-C-FT

Manufacturer Part Number
SI2457-C-FT
Description
IC ISOMODEM SYSTEM-SIDE 24TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2457-C-FT

Package / Case
24-TSSOP
Mfg Application Notes
SI2493/57/34/15/04, Appl Note AN93
Data Format
V.21, V.22, V.23, V.32, V.34, V.90, Bell 103, Bell 212A
Baud Rates
56k
Interface
Parallel, UART
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Operating Frequency
4.92 MHz
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current
26 mA
Operating Temperature Range
0 C to + 70 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2457-C-FT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
SI2457-C-FT
Manufacturer:
MURATA
Quantity:
10 122
Part Number:
SI2457-C-FTR
Manufacturer:
SILTCON
Quantity:
20 000
Si2457/34/15/04-Si3008
26
+GCI = X
+GCI?
+GCI = ?
+IFC Options
+IFC = A
+IFC = A,B
+ITF Options
+ITF = A
+ITF = A,B
+ITF = A,B,C
Command
Table 11. Basic AT Command Set (Command Defaults in Bold) (Continued)
Country settings - Automatically configure all registers for a particular country.
X
0
16
20
26
27
35
50
51
53
6C
73
89
8A
9C
B8
B5
FE
Note: U-registers are configured to Silicon Laboratories’ recommended values. The +GCI command
List current country code setting (response is: + GCI:<setting>)
List all possible country code settings.
Specifies the flow control to be implemented.
A
B
Transmit flow control threshold.
A
B
C
Specifies the flow control method used by the modem to control data from the host
Specifies the flow control method used by the host to control data from the modem
0 None
1 Local XON/OFF flow control.
2 Hardware flow control (CTS).
Threshold above which the modem will generate a flow off signal
<0 to 511> bytes
Threshold below which the modem will generate a flow on signal
<0 to 511> bytes
Polling interval for <EM><BNUM> indicator
0 to 300 in 10 msec units.
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remote
2 Hardware flow control (RTS)
resets the U-registers and the S7 and S6 S-registers to default values before setting country-
specific values. Changes may be made by writing individual registers after sending the
AT+GCI command. Refer to “AN93: Modem Designer’s Guide” for details.
modem.