CJ1W-MD233 Omron, CJ1W-MD233 Datasheet

no-image

CJ1W-MD233

Manufacturer Part Number
CJ1W-MD233
Description
TERM BLOCK I/O 16IN 16OUT 24DC
Manufacturer
Omron
Datasheet

Specifications of CJ1W-MD233

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CJ1WMD233
Basic I/O Selection
This section describes the standard and high-density input and output modules,
terminal blocks and cables used in a CJ1 system.
Input Configuration
What input voltage do you need?
How many input points are required?
Choose from the available point densities below.
What are the input current requirements?
Are terminal blocks and connection cables necessary?
Input modules with 8 or 16 points have built-in terminal strips that accept direct wiring from input devices. High-density 32- and 64-point modules
use cables and terminal blocks to connect inputs and consolidate wiring back to the control panel. For more information, see pages B-37 to B-38.
Note: For more information on wiring connections, please refer to the wiring section starting on page D-1.
Model number
See page
DC inputs
AC inputs
See page
DC inputs
AC inputs
See page
Module
CJ1W-IA111
CJ1W-IA201
CJ1W-ID211
CJ1W-ID231
CJ1W-MD231
CJ1W-ID261
CJ1W-MD261
CJ1W-ID232
CJ1W-MD233
CJ1W-ID262
CJ1W-MD263
CJ1W-MD563
Type
Input Points
Input Current
Connector Type
3.5 mA or Below
CJ1W-MD563
B-54
Removable screw terminal strip
Fujitsu connector on module
MIL-type flat ribbon connector on
module
DC Inputs
CJ1W-ID2
CJ1W-MD
B-37, B-54
8
CJ1W-ID201
CJ1W-IA201
B-37
4.1 mA or Below
CJ1W-ID231
CJ1W-ID232
CJ1W-ID261
CJ1W-ID262
CJ1W-MD261
CJ1W-MD263
B-37, B-54
16
CJ1W-ID211
CJ1W-IA111
B-37
Terminal Block
Not required
XW2B-40G4 or XW2B-40G5
Two XW2B-40G4 or XW2B-40G5
XW2B-40G4 or XW2B-40G5
Two XW2B-40G4 or XW2B-40G5
7 mA or Below
CJ1W-ID211
CJ1W-MD231
CJ1W-MD232
CJ1W-MD233
CJ1W-IA111
B-37, B-54
C J 1 B A S I C I / O M O D U L E S
AC Inputs
32
CJ1W-IA
B-37
CJ1W-ID231
CJ1W-ID232
CJ1W-MD231
CJ1W-MD232
CJ1W-MD233
B-37, B-54
9 mA or Below
CJ1W-IA201
B-37
Cable
Not required
XW2Z-
Two XW2Z-
XW2Z-
Two XW2Z-
64
CJ1W-ID261
CJ1W-ID262
CJ1W-MD261
CJ1W-MD263
CJ1W-MD563
B-37, B-54
B
K
B
K
10 mA or Below
CJ1W-ID201
B-37
B-35

CJ1W-MD233 Summary of contents

Page 1

... CJ1W-MD232 CJ1W-MD233 CJ1W-IA111 – B-37 B-37, B-54 4 Below Below CJ1W-ID231 CJ1W-ID211 CJ1W-ID232 CJ1W-MD231 CJ1W-ID261 CJ1W-MD232 CJ1W-ID262 CJ1W-MD233 CJ1W-MD261 CJ1W-MD263 – CJ1W-IA111 B-37, B-54 B-37, B-54 Terminal Block Not required XW2B-40G4 or XW2B-40G5 Two XW2B-40G4 or XW2B-40G5 XW2B-40G4 or XW2B-40G5 Two XW2B-40G4 or XW2B-40G5 64 CJ1W-ID261 CJ1W-ID262 ...

Page 2

... For more I/O options, see the Industrial Networking section for DeviceNet I/O on page B-88 and CompoBus/S I/O on page B-97. B- CJ1W-OD21 CJ1W-OD23 CJ1W-MD23 CJ1W-OC211 – – – – – CJ1W-OD211 CJ1W-OD231 CJ1W-OD233 CJ1W-MD231 CJ1W-MD233 CJ1W-OD212 CJ1W-OD232 Terminal Block Not required XW2B-40G4 or XW2B-40G5 Two XW2B-40G4 or XW2B-40G5 XW2B-40G4 or XW2B-40G5 Two XW2B-40G4 or XW2B-40G5 64 See page B-44 CJ1W-OD26 CJ1W-MD26 B-54 – B-44 – B-44 ...

Page 3

... Basic I/O Modules Input Modules Input Modules (64 points) CJ1W-ID26j Input current Model 10 mA CJ1W-ID201 7 mA CJ1W-ID211 4.1 mA CJ1W-ID231 4.1 mA CJ1W-ID232 4.1 mA CJ1W-ID261 4.1 mA CJ1W-ID262 Input current Model 7 mA (100 V, 50 Hz) CJ1W-IA111 9 mA (200 V, 50 Hz) CJ1W-IA201 Connecting Cable (order two) XW2Z-jj0B (for Fujitsu connector-type Modules) ...

Page 4

... Basic I/O Modules Input Modules Wiring and Cabling Examples (continued) 8-Point and 16-Point Input Modules (Optional) CJ1W-ID211, CJ1W-IAjj1, and CJ1W-ID201 Note: Since the 8- and 16-point I/O Modules have integrated screw terminals, this wiring configuration is necessary only if you are connecting to Omron XW2B Terminal Blocks ...

Page 5

... Input Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-ID211 Circuit configuration Input indicator CJ1W-ID231 Circuit configuration Word m Input indicator Word m+1 Basic I/O Modules Terminal arrangement Terminal arrangement Word m+1 Word m Programmable Controller Input Modules 24 VDC CJ1 B-39 ...

Page 6

... Basic I/O Modules Input Modules Input Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-ID232 Circuit configuration Word m Input indicator Word m+1 CJ1W-ID261 Circuit configuration Input indicator B-40 Programmable Controller Terminal arrangement Word m+1 Word m Terminal arrangement Word m+1 Indicator switching circuit ...

Page 7

... Input Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-ID262 Circuit configuration Input indicator CJ1W-IA111 Circuit configuration to CJ1W-IA201 Circuit configuration to Terminal arrangement CN1 Word m Indicator switching circuit Word m+1 Terminal arrangement Terminal arrangement Programmable Controller Basic I/O Modules Input Modules CN2 24 VDC ...

Page 8

... ON, the CPU is notified immediately, cyclic task execution is interrupted, and an I/O interrupt task is executed. J Specifications Module Model Input voltage Interrupt CJ1W-INT01 24 VDC Input Module Circuit configuration Input indicator Additional Information: For more details and specifications on any of these modules, refer to manual No. W393. B-42 Programmable Controller ...

Page 9

... Input data in the internal circuits is cleared during the input refresh period. J Specifications Module Model Input voltage Pulse Catch CJ1W-IDP01 24 VDC Input Module Circuit configuration Input indicator Additional Information: For more details and specifications on any of these modules, refer to manual No. W393. Inputs Input signal pulse No ...

Page 10

... Connections Model Removable terminal block CJ1W-OC201 CJ1W-OC211 Connections Model CJ1W-OD201 Removable terminal block CJ1W-OD202 CJ1W-OD203 CJ1W-OD204 CJ1W-OD211 Removable terminal block CJ1W-OD212 Fujitsu-compatible CJ1W-OD231 connector CJ1W-OD232 MIL connector CJ1W-OD233 Fujitsu-compatible CJ1W-OD261 connector CJ1W-OD262 MIL connector CJ1W-OD263 Connections Model Removable terminal block CJ1W-OA201 ...

Page 11

... XW2Z-jj0K (for MIL connector-type Modules) Connector Terminal Block XW2B-40G4 XW2B-40G5 8-Point and 16-Point Output Modules (Optional) CJ1W-OD20j and CJ1W-OD21j, CJ1W-OA201, CJ1W-OC2j1 Note: Since the 8- and 16-point I/O Modules have integrated screw terminals, this wiring configuration is necessary only if you are connecting to Omron XW2B Terminal Blocks ...

Page 12

... CJ1W-OC201 Circuit configuration Output indicator CJ1W-OC211 Circuit configuration Output indicator B-46 Programmable Controller 64-Point Output Modules CJ1W-OD26j Connecting Cable (Order two) G79-OjC-j (for Fujitsu connector-type Modules) G79-OjC-j-D1 (for MIL connector-type Modules) Terminal arrangement 2 A, 250 VAC VDC max. Terminal arrangement 2 A, 250 VAC VDC max ...

Page 13

... J Transistor Output Module Circuit Configuration and Terminal Arrangement CJ1W-OD201 Circuit configuration Output indicator CJ1W-OD202 Circuit configuration Short- circuit protec- tion Short- circuit protec- tion Terminal arrangement to Fuse to Fuse Terminal arrangement to to Programmable Controller Basic I/O Modules Output Modules VDC VDC 24 VDC ...

Page 14

... Basic I/O Modules Output Modules Transistor Output Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-OD203 Circuit configuration CJ1W-OD204 Circuit configuration CJ1W-OD211 Circuit configuration Output indicator B-48 Programmable Controller Terminal arrangement Terminal arrangement Terminal arrangement VDC CJ1 ...

Page 15

... Transistor Output Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-OD212 Circuit configuration Short- circuit protec- tion Output indicator ERR indicator CJ1W-OD231 Circuit configuration Output indicator Terminal arrangement Terminal arrangement Word m Word VDC Word m+1 Programmable Controller Basic I/O Modules Output Modules ...

Page 16

... Transistor Output Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-OD232 Circuit configuration Short- circuit protec- tion Output indicator Short- circuit protec- tion ERR indicator CJ1W-OD233 Circuit configuration B-50 Programmable Controller Terminal arrangement Word m Word m+1 Word m+1 Word m Terminal arrangement to Word m Word m+1 ...

Page 17

... Transistor Output Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-OD261 Circuit configuration Output indicator CJ1W-OD262 Circuit configuration Basic I/O Modules Terminal arrangement Word m Word m+1 Word m VDC VDC 24 VDC Terminal arrangement Programmable Controller Output Modules Word m CJ1 B-51 ...

Page 18

... Basic I/O Modules Output Modules Transistor Output Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-OD263 Circuit configuration B-52 Programmable Controller Terminal arrangement CN1 Word m Word m+1 CJ1 CN2 24 24 VDC VDC Word m+3 Word m VDC VDC ...

Page 19

... J Triac Output Module Circuit Configuration and Terminal Arrangement CJ1W-OA201 Circuit configuration Output indicator Terminal arrangement Fuse Basic I/O Modules Output Modules 250 VAC max. CJ1 Programmable Controller B-53 ...

Page 20

... VDC, 0.3 A/pt, 3.2 A/Unit, sinking outputs , g p Input Max. output switching capacity current (typical) 3 VDC, 35 mA/pt, 1.12 A/Unit CJ1 Connections Model Fujitsu-compatible CJ1W-MD231 connector MIL connector CJ1W-MD232 MIL connector CJ1W-MD233 Fujitsu-compatible CJ1W-MD261 connector MIL connector CJ1W-MD263 Connections Model MIL connector CJ1W-MD563 ...

Page 21

... Additional Information: For more details and specifications on cables and terminal blocks, refer to Manual No. W393 or check the Wiring Solutions section of this catalog for more options. 32-Point Mixed I/O Modules CJ1W-MD231 (Fujitsu connector, I/O Unit) CJ1W-MD232 (MIL connector, I/O Unit) CJ1W-MD233 (MIL connector, I/O Unit) Unit with Fujitsu Connector Unit with MIL Connector Connecting Cable G79-jC (for Fujitsu connector) ...

Page 22

... Basic I/O Modules Mixed I/O Modules J Mixed I/O Module Circuit Configuration and Terminal Arrangement CJ1W-MD231 Circuit configuration CJ1W-MD232 Circuit configuration B-56 Programmable Controller Terminal arrangement CJ1 Terminal arrangement ...

Page 23

... Mixed I/O Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-MD233 Circuit configuration CJ1W-MD261 Circuit configuration Terminal arrangement Terminal arrangement Programmable Controller Basic I/O Modules Mixed I/O Modules CJ1 B-57 ...

Page 24

... Basic I/O Modules Mixed I/O Modules Mixed I/O Module Circuit Configuration and Terminal Arrangement (continued) CJ1W-MD263 Circuit configuration CJ1W-MD563 Circuit configuration B-58 Programmable Controller Terminal arrangement Terminal arrangement CJ1 ...

Page 25

... CJ1W-B7A22 CJ1W-B7A14 CJ1W-B7A04 J Features • Wire remote switches, lamps, and other devices without being concerned with communications while also reduc- ing wiring both inside and outside the control panel. • Handles signals with each module. • Communications possible for up to 500 m. ...

Page 26

... High Speed (3 ms) Normal (19.2 ms) High Speed (3 ms) Transmission Delay Normal (19.2 ms High Speed (3 ms Normal (19.2 ms) High Speed (3 ms) Normal (19.2 ms) High Speed (3 ms) Normal (19.2 ms) High Speed (3 ms) CJ1 CJ1W-B7A04 64 outputs Model Transmission Delay B7AM-6BS Normal (19.2 ms High Speed (3 ms B7AS-RT3BS ...