SI3015-F-FS Silicon Laboratories Inc, SI3015-F-FS Datasheet - Page 33

IC ISOMODEM LINE-SIDE 16SOIC

SI3015-F-FS

Manufacturer Part Number
SI3015-F-FS
Description
IC ISOMODEM LINE-SIDE 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheets

Specifications of SI3015-F-FS

Package / Case
16-SOIC (3.9mm Width)
Data Format
V.90
Interface
Serial
Voltage - Supply
3.3 V ~ 5 V
Mounting Type
Surface Mount
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
26 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Baud Rates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3015-F-FS
Quantity:
3 000
Part Number:
SI3015-F-FSR
Manufacturer:
SAMSUNG
Quantity:
2 000
Part Number:
SI3015-F-FSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
5. S-Registers
The S command allows reading (Sn?) or writing (Sn=x) the S-registers. The S-registers store values for functions
that, typically, are rarely changed, such as timers or counters, and the ASCII values of control characters, such as
carriage return. Table 13 summarizes the S-register set.
S-Register
(Decimal)
10
12
14
24
0
1
2
3
4
5
6
7
8
9
Automatic answer—Number of rings the Si2403 must
detect before answering a call. 0 disables auto answer.
Ring counter.
ESC code character.
Carriage return character.
Linefeed character.
Backspace character.
Dial tone wait timer—Number of seconds the Si2403
waits before blind dialing. Only applicable if blind dial-
ing is enabled (X0, X1, X3).
Carrier wait timer—Number of seconds the Si2403
waits for carrier before timing out. This register also
sets the number of seconds the modem waits for ring-
back when originating a call before hanging up. This
register also sets the number of seconds the answer
tone will continue while using the AT
Dial pause timer for , and < dial command modifiers.
Carrier presence timer—Time after a loss of carrier
that a carrier must be detected before reactivating
DCD. S9 is referred to as “carrier loss debounce time.”
Carrier loss timer—Time the carrier must be lost
before the Si2403 disconnects. Setting 255 disables
disconnect entirely. If S10 is less than S9, even a
momentary loss of carrier causes a disconnect.
Escape code guard timer—Minimum guard time
required before and after “+++” for the Si2403 to rec-
ognize a valid escape sequence.
Wait for dial tone delay value (in relation to the W dial
modifier). Starts when “W” is executed in the dial
string.
Sleep Inactivity Time—Sets the time that the modem
operates in normal power mode with no activity on the
serial port, parallel port, or telephone line before enter-
ing low-power sleep mode. This feature is disabled if
the timer is set to 0.
Function
Table 13. S-Register Descriptions
*
Definition
Y2A command.
Rev. 1.2
(Decimal)
13 (CR)
Default
08 (BS)
10 (LF)
43 (+)
02
80
06
14
50
12
02
0
0
0
Range
0–255
0–255
0–255
0–255
0–255
0–255
0–255
0–255
0–255
1–255
1–255
1–255
0–255
0–255
Si2403
0.02 seconds
0.1 seconds
0.1 seconds
seconds
seconds
seconds
seconds
seconds
ASCII
ASCII
ASCII
ASCII
Units
Rings
Rings
33