Teaching
Operation
Operation
• Use the Bank/Function Key to set teaching (Function No. d) and press the Set Key to display the bank
• Next, press the Set Key to display the cam number in the Cam/Parameter No. display.
• Press the Cam/Parameter Key until the cam number to be set is displayed.
3-84
number in the Bank/Function display (flashing). Use the Up and Down Keys to set the bank number
that contains the cam to which the teaching function will be applied.
If there is no cam program for that cam number
If there is a cam program for that cam number
The SPEED/ON display will be “-- -- --” and the POSITION/OFF display will be “-- -- --.”
The ON and OFF angles for step 1 will be displayed.
Press the Set Key to display the ON and OFF angles for step 2.
Press the Set Key while the last step is displayed. The displays will be “-- -- --” and “-- -- --.”
Use the mode selection switch to change to SET mode.
Teaching (bank number 1)
Teaching (bank number 2)
Teaching (bank number 8)
Up to bank number 4 for 720
resolution
Bank number
selection enabled
Teaching (bank number 1, cam number 1)
Teaching (bank number 2, cam number 1)
Teaching (bank number 8, cam number 1)
Input by teaching and
step deletion enabled
Teaching (bank number 1, cam number 32)
Teaching (bank number 2, cam number 32)
Teaching (bank number 8, cam number 32)
Up to cam number 16 for
3F88L-160.
Up to cam number 16 for
3F88L-160.
Up to cam number 16 for
3F88L-160.
Chapter 3