XW2Z-100J-A5 Omron, XW2Z-100J-A5 Datasheet - Page 182

no-image

XW2Z-100J-A5

Manufacturer Part Number
XW2Z-100J-A5
Description
SERVO RELAY UNIT CABLES 1M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-A5

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JA5
Connect an External Regeneration Resistor between the B1 and B2 terminals.
Remove the short-circuit wiring between B2 and B2, and then connect an External Regeneration
Resistor between the B1 and B2 terminals.
3-42
System Design and Installation
Servo Driver
Servo Driver
R7D-AP04L and R7D-AP04H
R7D-AP08H
Wiring External Regeneration Resistance
B1
B2
B1
B2
B3
External Regeneration Resistor
External Regeneration Resistor
← Remove
Note When using the R88A-RR22047S, connect the
Note 1. The short-circuit wiring between B2 and B3 must be removed.
thermal switch output so that the power supply will
be shut off when open.
2. When using the R88A-RR22047S, connect the thermal switch
output so that the power supply will be shut off when open.
Chapter 3