CV500-CN22A Omron, CV500-CN22A Datasheet - Page 157
CV500-CN22A
Manufacturer Part Number
CV500-CN22A
Description
CONNECTING CABLE 2M
Manufacturer
Omron
Datasheet
1.R88A-CAU001.pdf
(324 pages)
Specifications of CV500-CN22A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CV500CN22A
- Current page: 157 of 324
- Download datasheet (3Mb)
Operation
Origin Search Pattern 2: Starting With Origin Proximity Input Signal ON
Note After the RUN command (RUN) signal turns ON, there will be an interval of 110 ms max. before
1. Positioning begins in the origin search direction at the origin search low speed.
2. The origin is established by the first Z-phase signal that is received after the origin proximity signal
turns OFF (falling edge).
RUN command
(RUN)
Origin search
(SEARCH)
CCW limit input
(CCWL)
Origin proximity
(ORG)
Z-phase
READY
Origin search
completed
(S.COM)
Origin (ORGSTP)
Positioning
completed
(INP)
Motor operation
(speed)
the READY signal and the positioning completed (INP) signal turn ON.
Origin search low speed
First Z-phase signal after
ORG turns OFF
Chapter 3
3-45