CJ1W-PD022 Omron, CJ1W-PD022 Datasheet - Page 3

no-image

CJ1W-PD022

Manufacturer Part Number
CJ1W-PD022
Description
POWER SUPPLY 24VDC 19.6W
Manufacturer
Omron
Datasheet

Specifications of CJ1W-PD022

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CJ1WPD022
Specifications
Supply voltage
Operating voltage
and frequency
ranges
Power consumption 100 VA max.
Inrush current *1
Output capacity *7
Output terminal
(service supply)
RUN output *2
Replacement
notification function
Insulation
resistance
Dielectric strength
*4
Noise immunity
Vibration resistance
Shock resistance
Ambient operating
temperature
Ambient operating
humidity
Atmosphere
Ambient storage
temperature
Grounding
Enclosure
Weight
Power Supply Unit
Item
100 to 240 V AC (wide-range), 50/60 Hz
85 to 264 V AC, 47 to 63 Hz
At 100 to 120 V AC:
15 A/8 ms max. for cold start at room temperature
At 200 to 240 V AC:
30 A/8 ms max. for cold start at room temperature
5.0 A, 5 V DC (including supply to CPU Unit)
0.8 A, 24 V DC
Total: 25 W max.
Not provided.
Contact configuration:
SPST-NO
Switch capacity:
250 V AC, 2 A (resistive
load)
120 V AC, 0.5 A
(inductive load), 24 V DC,
2A (resistive load)
24 V DC, 2 A (inductive load)
Not provided.
20 MΩ min. (at 500 V DC)
between AC external and
GR terminals
*3
2,300 V AC 50/60 Hz
for 1 min between AC
external and GR terminals
*3
Leakage current: 10 mA
max.
1,000 V AC, 50/60 Hz for 1 minute between DC external and GR terminals *3
Leakage current: 10 mA max.
2 kV on power supply line (conforming to IEC61000-4-4)
Conforms to IEC60068-2-6
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s
Conforms to IEC60068-2-27
147 m/s
0 to 55°C
10% to 90% (with no
condensation)
Must be free from corrosive gases.
−20 to 70°C (excluding
battery)
Less than 100 Ω
Mounted in a panel.
All models are each 5 kg max.
CJ1W-PA205R
2
, 3 times in X, Y, and Z directions (100 m/s
2
for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min)
Not provided.
With Alarm output (open-
collector output)
30 V DC max., 50 mA
max.
• 20 MΩ min. (at 500 V
• 20 MΩ 1 min. (at 250 V
• 2,300 VAC, 50/60 Hz for
• 1,000 V AC, 50/60 Hz
10% to 90% (with no
condensation)
*5
−20 to 75°C (See note 5.) −20 to 75°C (excluding battery)
DC) between all
external terminals and
GR terminal *3, and
between all alarm
output terminals.
DC) between all alarm
output terminals and
GR terminal *3.
1 minute between all
external terminals and
GR terminal *3 and
between all alarm
output terminals with a
leakage current of 10
mA max.
for 1 minute between all
alarm output terminals
and GR terminal *3 with
a leakage current of 10
mA max.
CJ1W-PA205C
2
for Relay Output Units)
50 VA max.
At 100 to 120 V AC:
20 A/8 ms max. for cold
start at room temperature
At 200 to 240 V AC:
40 A/8 ms max. for cold
start at room temperature
2.8 A, 5 V DC
(including supply to CPU
Unit)
0.4 A, 24 V DC
Total: 14 W max.
Not provided.
20 MΩ min. (at 500 V DC)
between AC external and
GR terminals
*3
2,300 V AC 50/60 Hz
for 1 min between AC
external and GR terminals
*3
Leakage current: 10 mA
max.
10% to 90% (with no condensation)
Specifications
CJ1W-PA202
24 VDC
19.2 to 28.8 V DC
50 W max.
At 24 V DC:
30 A/20 ms max. for cold start at room temperature
5.0 A, 5 V DC
(including supply to CPU
Unit)
0.8 A, 24 V DC
Total: 25 W max.
20 MΩ min. (at 500 V DC)
between DC external and
GR terminals
*3
1,000 V AC, 50/60 Hz for
1 minute between DC
external and GR terminals
*3
Leakage current: 10 mA
max.
CJ1W-PD025
CJ1W-PA/PD
21.6 to 26.4 V DC
35 W max.
2.0 A, 5 V DC
(including supply to CPU
Unit)
0.4 A, 24 V DC
Total: 19.6 W max.
CJ1W-PD022
*6
*6
3