SI2401-FS Silicon Laboratories Inc, SI2401-FS Datasheet - Page 28

IC ISOMODEM SYSTEM-SIDE 16SOIC

SI2401-FS

Manufacturer Part Number
SI2401-FS
Description
IC ISOMODEM SYSTEM-SIDE 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Integrated Global DAAr
Datasheets

Specifications of SI2401-FS

Package / Case
16-SOIC (3.9mm Width)
Data Format
V.21, V.22, V.23, Bell 103, Bell 212A
Baud Rates
2.4k
Interface
UART
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
15 mA
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 10 C
Mounting Style
SMD/SMT
Package
16SOIC
Main Category
Chipset
Sub-category
ISOmodem
Maximum Data Rate
2.4 Kbps
Typical Operating Supply Voltage
3.3 V
Power Supply Type
Digital
Typical Supply Current
10 mA
Minimum Operating Supply Voltage
3 V
Maximum Operating Supply Voltage
3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1167 - BOARD EVAL SI2401 UART INTERFACE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
336-1095

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2401-FS
Manufacturer:
VIMICOR
Quantity:
10
Part Number:
SI2401-FS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI2401-FSR
Manufacturer:
GENNUM
Quantity:
7
Part Number:
SI2401-FSR
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
SI2401-FSR
Quantity:
1 318
Si2401
send the first SIA block after the “c” is received. Once
the block is transmitted, the modem can monitor for the
acknowledge
sequence:
1. Place the Si2401 in command mode by pulsing the
2. Issue the “ATX1” command to turn the modem
3. Monitor for a positive (negative) acknowledgment “P”
4. The modem, still in command mode, can be placed
This sequence can be repeated for long messages.
5.5. Modem Result Codes and Call
Table 14 shows the modem result codes that can be
used in call progress monitoring. All result codes are a
single character to speed up communication and ease
host processing.
28
ESCAPE pin (Si2401 pin 14). The “+++” and “ninth-
bit” escape modes operate in the “!2” mode but are
not recommended because they can send unwanted
characters to the remote modem.
transmitter off and begin monitoring for the
acknowledgment tones.
(“N”) after the tone has been detected for at least
400 ms.
online as a transmitter by issuing the “ATX2”
command or a receiver by issuing the “ATX3”
command. If tonal acknowledgement is not used, the
host can toggle the ESCAPE pin to place the Si2401
in the command mode and issue an “ATX2” or an
“ATX3” command to reverse data direction.
Progress
tone
by
completing
the
following
Rev. 1.0
Command
m
O
H
K
N
R
a
b
c
d
k
L
n
v
x
^
f
I
r
t
,
i
l
Table 14. Modem Result Codes
Function
Alert Detected
Busy Tone Detected
grammed as V.22bis modem)
Detected
Modem Automatically Hanging Up in
!2, !1
Intrusion Completed (parallel phone
back on-hook)
Intrusion Detected (parallel phone off-
hook on the line)
Kissoff Tone Detected
Contact ID Kissoff Tone too long (!1)
Phone Line Detected
No Phone Line Detected
Caller ID Mark Signal Detected
No Carrier Detected
No Dial tone (time-out set by CW
[S02])
Modem OK Response
Incoming Ring Signal Detected
Ringback Tone Detected
Dial Tone
Connect 75 bps TX (V.23 originate
only)
Overcurrent State Detected After an
Off-Hook Event
Kissoff tone detection required
Dialing Complete
British Telecom Caller ID Idle Tone
Connect
Connect 1200 bps (when pro-
Hookswitch Flash or Battery Reversal

Related parts for SI2401-FS