N1913A-107 AGILENT TECHNOLOGIES, N1913A-107 Datasheet

RF POWER METER, 90V To 264V

N1913A-107

Manufacturer Part Number
N1913A-107
Description
RF POWER METER, 90V To 264V
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N1913A-107

Analyzer Functions
Frequency, Power
No. Of Channels
1
Voltage Range Rms
90V To 264V
Accuracy
Logarithmic
External Height
88.5mm
External Width
212.6mm
Rohs Compliant
NA
As signals become more complex, it
becomes more difficult to make fast,
accurate power measurements. For
years, you’ve depended on Agilent’s
EPM Series power meters. Today,
the Agilent N1913A and N1914A
EPM power meters are versatile,
user-friendly replacements for the
E4418B/19B EPM Series. Best of
all, you get these extras for about
the same price as the EPM Series.
Get consistent results and greater
capability—with the new EPM power
meters.
Essential specifications
• Frequency range: 9 kHz to
• Power range: –70 dBm to
• Measurement speed: Up to
• Absolute accuracy: ±0.02 dB
• Relative accuracy: ±0.04 dB
110 GHz
+44 dBm (100 pW to 25 W,
depending on the attached
power sensor)
400 readings/sec with
E-Series sensors
logarithmic, ±0.5% linear
logarithmic, ±1% linear
Agilent N1913A and N1914A
EPM Series Power Meters
Consistent Results and Greater Capability
Data Sheet
Do more with new-generation EPM power meters
• Get up to four channels
• Measure faster with improved measurement speed of 400 readings/sec with
• View test results more easily with the industry’s first color LCD readout in an
• Go beyond GPIB with USB and LAN/LXI-C interfaces
• Automate frequency/power sweep measurements with the optional external
• Confirm battery power with a single-button push
• Easily replace existing 436A. 437B and 438A meters with optional 43x code
• Enhance manufacturing test by connecting a large external monitor with the
1. Additional two optional USB channels available (see Ordering Information, page 10)
2. Only applicable for models with battery option (see Ordering Information, page 10)
3. N1913A is backward compatible with the 436A and 437B, while N1914A is compatible with 438A
the Agilent E-Series sensors
average power meter
trigger in/out feature
time with the optional spare battery
compatibility
unique VGA output option
3
1
to speed and simplify RF average power measurements
2
—and get extra operating

N1913A-107 Summary of contents

Page 1

... VGA output option 1. Additional two optional USB channels available (see Ordering Information, page 10) 2. Only applicable for models with battery option (see Ordering Information, page 10) 3. N1913A is backward compatible with the 436A and 437B, while N1914A is compatible with 438A 2 —and get extra operating ...

Page 2

Take a Closer Look N1914A front panel Industry’s first high-resolution color LCD in an average power meter Display keys select the display format for the active window (single/split screen) Hard keys provide quick access to the most frequently used functions, ...

Page 3

... E4412A/3A Two-path diode-stack ● ● sensors: E9300 Series USB sensors: ● ● U2000 Series * The N1913A/4A power meters are compatible with all 8480 Series power sensors, including discontinued models. Modulated Wireless standards AM/FM profiled Mobile phone Mobile GSM CDMA2000 3G radio EDGE ...

Page 4

... N1913A/14A EPM Series Power Meters Performance Characteristics Specifications describe the instrument’s warranted performance and apply after a 30 minute warm-up. These specifications are valid over its operating/ environmental range unless otherwise stated and after performing a zero and calibration procedure. Supplemental characteristics (shown in italics) are intended to provide addi- tional information, useful in applying the instrument by giving typical (expected), but not warranted performance parameters ...

Page 5

... N1913A/14A EPM Series Power Meters Performance Characteristics 1 mW power reference Power output 1.00 mW (0.0 dBm). Factory set to ±0.4 % traceable to the National Physical Laboratories (NPL), UK Accuracy (for two years) ±0.4% (25 ±10 ºC) ±1. ºC) Frequency 50 MHz nominal SWR 1.05 (typical), 1. 55ºC) Connector type Type-N (f), 50 Ω ...

Page 6

... N1913A/14A EPM Series Power Meters Performance Characteristics Settling time 1 Manual filter, 10-dB decreasing power step for normal and x2 modes (not across range switch points for E-Series and N8480 Series sensors). Table 3. Settling time Number of averages 1 Settling time with E-Series sensors (s) Normal mode ...

Page 7

... N1913A/14A EPM Series Power Meters Performance Characteristics Settling time (continued) Auto filter decreasing power step for normal and X2 modes (not across the range switch points for E-Series and N8480 Series sensors). x2 Normal speed speed Typical settling times –40 dBm 70 ms 120 ms – ...

Page 8

... N1913A/14A EPM Series Power Meters Performance Characteristics Power meter functions Accessed by key entry Either hard keys, or soft key menu, and programmable Zero Zeros the meter. (Power reference calibrator is switched off during zeroing.) Cal Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150 ...

Page 9

... The following information describes characteristic performance based at a temperature of 25 °C unless otherwise noted. Typical operating time hours with LCD backlight on 7.5 hours with LCD backlight off (N1913A power meter). Charge time Approximately, 2.5 hours to charge fully from an empty state. Power meter is operational whilst charging. ...

Page 10

... N1913A/14A EPM Series Power Meters Ordering Information Power meters N1913A Single-channel average power meter N1914A Dual-channel average power meter Standard-shipped accessories Power cord Power sensor cable, 1 ft) (One per N1913A, two per N1914A) USB cable Type A to Mini- Hard copy English language User’s ...

Page 11

E-Series Power Sensor Specifications The E-Series of power sensors have their calibration factors stored in EEPROM and operate over a wide dynamic range. They are designed for use with the EPM Series of power meters and two classes of sensors ...

Page 12

E-Series CW Power Sensor Specifications Calibration factor (CF) and reflection coefficient (Rho) Calibration factor and reflection coefficient data are provided at 1 GHz increments on a data sheet included with the power sensor. This data is unique to each sensor. ...

Page 13

E-Series CW Power Sensor Specifications Power linearity Table 6. E4410 Series power linearity specification Power 100 (–70 dBm to +10 dBm 100 mW (+10 dBm to +20 dBm) +20 + –20 ...

Page 14

E-Series E9300 Average Power Sensor Specifications The E-Series E9300 wide dynamic range, average power sensors are designed for use with the EPM family of power meters. These specifications are valid ONLY after proper calibration of the power meter and apply ...

Page 15

E-Series E9300 Average Power Sensor Specifications 1.2 1.18 1.16 1.14 1.12 1.1 1.08 1.06 1.04 1.02 1 0.01 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 Frequency GHz Typical SWR, 10 MHz to 18 GHz (25 °C ±10 °C) ...

Page 16

E-Series E9300 Average Power Sensor Specifications Power linearity* Table 9. E9300 Series power linearity (after zero and cal at ambient environmental conditions) sensor Sensor Power E9300A, E9301A, E9304A –60 to –10 dBm – dBm 0 to +20 dBm ...

Page 17

E-Series E9300 Average Power Sensor Specifications Effects of change in temperature on linearity Note: If the temperature changes after calibration and you choose not to re-calibrate the sensor, the follow- ing additional power linearity error should be added to the ...

Page 18

E-Series E9300 Average Power Sensor Specifications Switch point data The E9300 power sensors have two paths as shown in Table 7. The power meter automatically selects the proper power level path. To avoid unnecessary switching when the power level is ...

Page 19

E-Series E9300 Average Power Sensor Specifications Calibration factor (CF) and reflection coefficient (Rho) Calibration factor and reflection coefficient data are provided at frequency intervals on a data sheet included with the power sensor. This data is unique to each sensor. ...

Page 20

Series Diode and 8483A Thermocouple Power Sensor Specifications Calibration factor uncertainties These thermocouple and diode power sensors provide extraordinary accuracy, stability, and SWR over a wide range of frequencies (100 kHz to 110 GHz) and power levels (–70 dBm ...

Page 21

Series Diode and 8483A Thermocouple Power Sensor Specifications (continued) Maximum SWR and power linearity Table 14. 8480 Series maximum SWR and power linearity Frequency Maximum Model range SWR 100 mW sensors, 1 μW to 100 mW (–30 dBm to ...

Page 22

N8480 Series Thermocouple Power Sensor Specifications The N8480 Series power sensors (excluding Option CFT) measure power levels from –35 dBm to +44 dBm (316 nW to 25.1 W), at frequencies from 100 kHz to 50 GHz and have two independent ...

Page 23

N8480 Series Thermocouple Power Sensor Specifications Maximum SWR and power linearity for standard N8480 Series power sensors Table 16. N8480 Series maximum SWR and power linearity Frequency Maximum 1 Model range SWR 3 100 mW sensors. Power range : 316 ...

Page 24

N8480 Series Thermocouple Power Sensor Specifications Switch point data Switching point is applicable for standard N8480 Series power sensors only. The N8480 Series power sensors have two power measurement ranges; a lower range and upper range. The power meter automatically ...

Page 25

... The U2000 Series USB power sensors are true average, wide-dynamic-range RF/microwave power sensors, based on a dual-sensor diode pair/attenuator/ diode pair topology. The U2000 Series USB power sensors can be operated on N1913A/14A via the USB host port (options). Frequency and power ranges Table 17. U2000 Series USB sensors frequency and power ranges ...

Page 26

U2000 Series USB Power Sensor Specifications Maximum SWR Table 19. U2000 Series USB sensors maximum SWR Model Frequency range U2000A 10 MHz to 30 MHz 30 MHz to 2 GHz 2 GHz to 14 GHz 14 GHz to 16 GHz ...

Page 27

... Spain 34 (91) 631 3300 Sweden 0200- Switzerland 0800 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: July 8, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2010 Printed in USA, October 12, 2010 5990-4019EN ...