9-520272-2 TE Connectivity, 9-520272-2 Datasheet - Page 5

Terminals 110 ULTRA-FAST RCPT 22-18 TPBR

9-520272-2

Manufacturer Part Number
9-520272-2
Description
Terminals 110 ULTRA-FAST RCPT 22-18 TPBR
Manufacturer
TE Connectivity
Datasheets

Specifications of 9-520272-2

Product
Fastons
Wire Size (awg)
22-18
Insulation
Insulated
Color
Black
Gender
Female
Contact Plating
Tin
Contact Material
Brass
Termination Style
Crimp
Insulation Material
Nylon
Mounting Angle
Straight
Mounting Method
Wire
Number Of Positions / Contacts
1
Number Of Rows
1
Terminal Type
Receptacle
Proprietary Name
Ultra-Fast
Receptacle Style
Straight
Mating Area Interface Dimensions (mm [in])
2.79 x 0.81 [.110 x .032], 3.18 x 0.81 [.125 x .032]
Insulation Diameter (mm [in])
3.05 [.120] Max.
Insulation Support
Non-Insulation Support
Finish
Tin
Wire Range (mm [awg])
0.30-0.90² [22-18]
Fully Insulated
Yes
Ul Flammability Rating
UL 94V-2
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
9-520272-2
Manufacturer:
TE
Quantity:
20 000
4.
4.1.
4.2.
4.3.
Rev D
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
C.
Quality Conform ance Inspection
The applicable inspection plan will specify the sam pling acceptable quality level to be used. Dim ensional
and functional requirem ents shall be in accordance with the applicable product drawing and this
specification.
Certification
This product has been recognized under the Com ponent Recognition Program of Underwriters
Laboratories Inc., Electrical File Num ber E-66717 and certified by Canadian Standards Association File
Num bers LR-7189. Also, VDE Testing and Certification Institute, Reference No. 4751_1431_1047.
Sam ple Selection
Term inals and tabs shall be prepared in accordance with applicable Instruction Sheets and shall
be selected at random from current production. Test groups 1, 2, 3 and 4 shall each consist of 20
sam ples of each wire size and term inal type per group. Test groups 5, 6, 7, 8, 9, 10, 11 and 12
shall each consist of 20 sam ples of each term inal type per group. All sam ples to be term inated
shall be crim ped to appropriate tin plated test conductors.
Test Sequence
Qualification inspection shall be verified by testing sam ples as specified in Figure 3.
Acceptance
1.
2.
Metal Plate Test Fixture
Requirem ents put on the test sam ples, as indicated in the Requirem ents portion of Figure 1,
exist as either the upper or lower statistical tolerance lim it (95% confidence, 98% reliability).
All sam ples tested in accordance with this specification shall m eet the stated tolerance lim it.
Failures attributed to equipm ent, test setup or operator deficiencies shall not disqualify the
product. W hen product failure occurs, corrective action shall be taken and sam ples
resubm itted for qualification.
Figure 4
Tab, Receptacle Entry Position
Figure 5
108-2043
5 of 5

Related parts for 9-520272-2