1785/26 100 3M, 1785/26 100 Datasheet

no-image

1785/26 100

Manufacturer Part Number
1785/26 100
Description
CABLE 26 COND FLAT TWSTD PR .05"
Manufacturer
3M
Series
1785r
Datasheets

Specifications of 1785/26 100

Cable Type
Flat Twisted Pair, Flat Jacket
Number Of Conductors
26
Pitch
0.050" (1.27mm)
Length
100' (30.5m)
Wire Gauge
28 AWG
Conductor Strand
7 Strands / 36 AWG
Shielding
Shielded
Color
Multiple
Jacket (insulation) Material
Poly-Vinyl Chloride (PVC)
Voltage Rating
150V
Operating Temperature
-20°C ~ 80°C
Color, Jacket
Black
Material, Conductor
Copper
Material, Insulation
Polyvinylchloride
Material, Jacket
Polyvinylchloride
Material, Shield
Expanded Copper
Standards
UL CL2, UL AWM 2912, cUL AWM IIA/B FT1
Stranding
7×36
Temperature, Rating
-20 to +80 °C
Wire, Awg
28
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
05111152599
80400007094
3M
.050" 28 AWG Stranded, Twisted Pair, PVC/PVC
Physical
Note: Unbalanced is measured between conductors within a pair with one conductor connected to the shield. Balanced is measured between conductors within a pair with the shield floating..
Environmental
*"RoHS Compliant 2005/95/EC" means that the product or part ("Product") does not contain any of the substances in excess of the maximum concentration values in EU Directive
UL File No.: E118773, Power Limited Circuit Cable CL2: (or AWM Style 2912)
3
Electrical
2002/95/EC, as amended by Commission Decision 2005/618/EC, unless the substance is in an application that is exempt under EU RoHS. This information represents 3M's
knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. In the event any product is proven not to conform with 3M’s
Regulatory Information Appendix, then 3M’s entire liability and Buyer’s exclusive remedy will be in accordance with the Warranty stated below.
Characteristic Impedance:
Shielded/Jacketed, Flat Cable
Velocity of Propagation:
Insulation Resistance:
Flammability Rating:
Temperature Rating:
Marking Standard:
Propagation Delay:
Jacket Material:
Voltage Rating:
Primary Material: PVC
Capacitance:
Conductors:
Inductance:
Shielding:
Color: Black
Color: 10 Color Repeat with Tan Common
Polyvinyl Chloride (PVC)
(UL) CL2 75C 28 AWG OR AWM 2912 3M NU C
28 AWG, 7 x 36 AWG [7 x Ø 0.127] Tinned Stranded Copper
Expanded Copper
USA: N.E.C. 725, CL2 or AWM 150V
(Primary Cable) >1 x 10
Unbalanced
67 Ω
24.7 pF/ft [ 81.0 pF/m ]
0.11 μH/ft [ 0.36 μH/m ]
1.65 ns/ft [ 5.41 ns/m ]
62%
USA: CL2;75°C or AWM:-20°C to +80°C
USA: N.E.C. 725, CL2
Date Modified: June 17, 2008
9
Meets external wiring requirements of National
Electrical Code, Article 725
UL listed for US and Canadian markets
Expanded copper shielding provides easier
termination than aluminum/mylar shielding
360 degree expanded copper shielding provides 20 db
average shielding effectiveness
Twist and flat repeat has variable length options
RoHS* compliant
Ω /10 ft [3 m]
Balanced
118 Ω
13.8 pF/ft [ 45.3 pF/m ]
0.19 μH/ft [ 0.62 μH/m ]
1.63 ns/ft [ 5.35 ns/m ]
62%
Canada: 150V
Canada: 80°C
Canada: FT1
3M is a trademark of 3M Company.
AWM IIA/B 80C 150V FT1 EU <50V
EU: <50V
1785 Series
Sheet 1 of 2
TS-0308-B

1785/26 100 Summary of contents

Page 1

... Commission Decision 2005/618/EC, unless the substance application that is exempt under EU RoHS. This information represents 3M's knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. In the event any product is proven not to conform with 3M’s Regulatory Information Appendix, then 3M’ ...

Page 2

... Number of Conductors (See Table) Note: 1. The twist-flat repeat can be specified from 8.5 inches (16.5 cm inches (1.219 m), and the flat can be specified as anything over 1 inch (2.54 cm). 2. Contact 3M for availability of custom roll lengths or other special requirements. 3 Number of 3M Part Number Conductors 10 (5 pair) ...