XRU1D120U EATON CUTLER HAMMER, XRU1D120U Datasheet - Page 11

TERM BLK RELAY, 120VAC/110VDC, 1PDT, SCREW, DIN RAIL MT

XRU1D120U

Manufacturer Part Number
XRU1D120U
Description
TERM BLK RELAY, 120VAC/110VDC, 1PDT, SCREW, DIN RAIL MT
Manufacturer
EATON CUTLER HAMMER
Series
XRr
Datasheet

Specifications of XRU1D120U

Contact Current Max
6A
Contact Voltage Dc Max
110V
Contact Configuration
1PDT
Relay Mounting
DIN Rail
External Width
6.2mm
Contact Voltage Ac Max
120V
March 2006
Product Description
Power Terminal Block
The XRAPLCESK power terminal block
has the same shape as the relay mod-
ules and is used to feed in the bridging
potentials. The nominal current is 32A.
When the total current is less than or
equal to 6A, supply can take place
directly at the connecting terminal
blocks of one of the connected relays.
Product Selection
Table 13. Product Selection Table for XR Series Accessories
Table 14. Power Terminal Block Technical Specifications
Connection Data
Miscellaneous Data
CA04900001E
Description
2-Position Snap-In Jumper
2-Position Snap-In Jumper
2-Position Snap-In Jumper
80-Position Snap-In Jumper
80-Position Snap-In Jumper
80-Position Snap-In Jumper
Power Terminal Block
End Cover
Description
Rigid Solid
AWG (mm
Flexible Stranded
AWG (mm
Max. Current
Max. Voltage
Approvals
The separating plate, XRAPLCESK, should be installed for voltages greater than 250V (L1, L2, L3)
between identical terminal points of adjacent modules. Potential bridging is then possible
with the XRAFBST bridge system.
2
2
)
)
Color
Red
Blue
Gray
Red
Blue
Gray
Gray
Black
For more information visit: www.EatonElectrical.com
Specification
24 – 10 (0.2 – 4)
24 – 10 (0.2 – 4)
32A
250V AC
End Cover
The XRAATPBK end cover is required
at the start and stop of a relay strip. It
can also be used for visual separation
of groups of relays as well as separat-
ing relays with voltages greater than
250V and separating neighboring
bridges with different potentials. It is
equipped with pre-scored break out
points at the bridging positions so that
individual bridges can be passed
through as needed. It may also be nec-
essary to use the end cover between
adjacent relays when three phases (L1,
L2, L3) are used on the contact side of
the relay.
Standard
Pack
10
10
10
5
5
5
5
5
XR Series Terminal Block Relays
Accessories
Catalog
Number
XRAFBST2RD
XRAFBST2BU
XRAFBST2GY
XRAFBST500RD
XRAFBST500BU
XRAFBST500GY
XRAPLCESK
XRAATPBK
Price
U.S. $
22.00
22.00
22.00
27.00
1.40
1.40
1.40
5.75
Bridges
The XRAFBST colored, insulated plug-
in bridge system reduces wiring time
by up to 70% compared to convention-
ally wired relays. The XRAFBST2,
2-position bridges, are suited for
bridging a smaller number of relays
and total currents ≤ 6A. When a circuit
is supplied from both sides, the circuit
can be opened at any point, allowing
all other modules to continue being
supplied at the same time. The
XRAFBST500 allow up to 80 modules
to be bridged at one time. If bridges
with different potentials meet in neigh-
boring modules, the end cover
XRAATPBK should be used. All
bridges are equipped with a groove for
removal with a standard screwdriver.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1
11