CPE-750P CUI Inc, CPE-750P Datasheet - Page 3

BUZZER PIEZO 12VDC 3.6KHZ PANEL

CPE-750P

Manufacturer Part Number
CPE-750P
Description
BUZZER PIEZO 12VDC 3.6KHZ PANEL
Manufacturer
CUI Inc
Series
CPEr
Type
Piezo Indicator, Internal Driver
Datasheet

Specifications of CPE-750P

Frequency
3.6kHz
Voltage - Rated
12VDC
Current Rating
7mA
Size / Dimension
Circular - 37.8mm Dia x 23.5mm H
Mounting Type
Panel Mount
Sound Pressure Level
80dB
Operating Mode
Continuous/Fast Pulse
Voltage Range
4 ~ 28VDC
Termination
Solder Pins/Posts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Frequency
-
Other names
102-1660
PART NUMBER: CPE-750P
RELIABILITY TEST
item
operating (life test)
TEST CONDITIONS
standard test condition
judgement test condition
ENVIRONMENT TEST
item
high temp. test
low temp. test
humidity test
temp. cycle test
20050 SW 112
th
Ave. Tualatin, Oregon 97062
a) tempurature: +5 ~ +35°C
a) tempurature: +25 ±2°C
test condition
1. Continuous life test:
The part will be subjected to 48 hours of
continuous operation at +70°C with rated
voltage applied.
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minutes off, a
minimum of 5,000 times at room temp
(+25 ±2°C) with rated voltage applied.
test condition
After being placed in a chamber at +95°C for
240 hours.
After being placed in a chamber at -40°C for
240 hours.
After being placed in a chamber at +40°C and
90±5% relative humidity for 240 hours.
The part shall be subjected to 5 cycles. One
cycle will consist of:
-40
0.5hr 0.5hr 0.25 0.5hr
phone
phone 503.612.2300 fax
+25
3hours
DESCRIPTION: panel mount piezo indicators
b) humidity: 45 - 85%
b) humidity: 60 - 70%
+95
0.5hr
0.5hr 0.25
+25
fax 503.612.2383
evaluation standard
evaluation standard
The buzzer will be measured after
The buzzer will be measured after
being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to
the initial measurements.
being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to the
initial measurements.
c) pressure: 860-1060 mbar
c) pressure: 860-1060 mbar
page
date
11/12/2007
3 of 5

Related parts for CPE-750P