57701461 Eaton / Control Automation, 57701461 Datasheet - Page 2

no-image

57701461

Manufacturer Part Number
57701461
Description
PROCESS METER; TEMPERATURE; ECLIPSE 85-265VAC; RELAY OUT
Manufacturer
Eaton / Control Automation
Type
Process/Temperaturer
Datasheet

Specifications of 57701461

Cut Out, Panel
1/8 DIN
Digit Height
0.56
Dimensions
4.04"L×2.19"H×3.31"D
Display Digit Height
0.56 "
Display Type
LED
Function
Process/Temperature
Measuring Range
Number Of Digits
4
Output
2
Voltage, Supply
85 to 265 VAC
Inputs
J, K, T Thermocouples; 4-Wire PT100 RTD (IEC 751)
Universal Power Supply
85-265 VAC
Protection
NEMA 4X when Mounted with Gasket Provided
Lead Free Status / Rohs Status
RoHS Compliant part
Features
Standards and Certifications
Technical Data and
Specifications
Input Power
Human Interface
PG05400001E
4 Full digits
1/8 DIN Size
Red, LED display
0.56" (14 mm) high characters
Scalable display
Flashing alarms
Maximum/minimum data hold
Optional analog, relay and RS-485
outputs
NEMA 4X
Depluggable terminal blocks
UL and cUL Listed, CE Marked
AC Powered Models (57751-4XX)
DC Powered Models (57750-4XX)
Display: ±4 full digits
Type: 0.56" (14 mm) high, seven
segment, red LED
Update Time: 0.4 seconds
Alarm: Flashing display
Indicator: One red LED program/
calibration indicator with max./min.
capture and hold
Input Power: 85 – 265V AC,
47 – 63 Hz, 20 VA
External Fuse: 0.2A, 250V AC,
Time Delay (T200mA, 250V)
Isolation Dielectric Strength:
2300V AC
Input Power: 9-30V DC, 12 VA
External Fuse: 2.0A, 50V DC, Time
Delay (T2A, 50V)
Reverse Voltage Protection: Yes
Isolation Dielectric Strength:
2300V AC to signal inputs and
relays, 500V AC to RS-485 and
analog outputs
Cat. No. 57700400
Data Retention
Signal Input
Memory Type: EEPROM, no batter-
ies required
Duration: 100 years
DC Voltage Models (5770X-40X) —
AC Voltage Models (5770X-41X) —
DC Current Models (5770X-42X) —
AC Current Models (5770X-43X)
Counters, Panel Meters, Tachometers and Timers
Digital Panel Meters
Eclipse Series — Durant
Range: ±199.9 mV DC, ±1.999V
DC, ±19.99V DC, ±199.9V DC, DIP
Switch Selectable
Impedance: 1 M
Overrange: 750V DC/530V AC
except 220V DC/AC on 199.9 mV
range
Accuracy: ±0.1% of reading,
±0.03% FS, ±0.5 digit, and ±80
PPM/°C
Range: 199.9 mV AC, 1.999V AC,
19.99V AC, 199.9V AC, DIP Switch
Selectable, all ranges true RMS
Frequency: 40 to 1000 Hz
Impedance: 1 M
coupled)
Overrange: 750V DC/530V AC
except 220V DC/AC on 199.9 mV
range
Accuracy: ±0.5% of reading,
±0.13% FS, ±0.5 digit, ±180 PPM/
°C for crest factor = 1; plus ±0.7%
for crest factor = 1 to 3; and ±2.5%
for crest factor = 5
Range: ±199.9 μA DC, ±1.999 mA
DC, ±19.99 mA DC, ±199.9 mA DC,
DIP Switch Selectable
Impedance: 199.9 mV/selected
range
Overrange: 30 mA (1 99.9 μA
range), 100 mA (1. 999 mA range),
300 mA (19.99 mA range), 1 A
(199.9 mA range)
Accuracy: ±0.1% of reading,
±0.03% FS, ±0.5 digit, and ±120
PPM/°C
Range: 199.9 μA AC, 1.999 mA
AC, 19.99 mA AC, 199.9 mA AC,
DIP Switch Selectable, all ranges
true RMS
Frequency: 40 to 1000 Hz
Impedance: 199.9 mV/selected
range (shunt output capacitive
coupled)
Overrange: 30 mA (11 99.9 μA
range), 100 mA (1.999 mA range),
300 mA (19.99 mA range), 1A
(199.9 mA range)
(ohms)
(capacity
®
Optional Outputs
5A AC Models (5770X-44X) —
Process Models (5770X-45X) —
Relay Board —
Analog Retransmission —
Accuracy: ±0.5% of reading,
±0.13% FS, ±0.5 digit, and ±200
PPM/°C for crest factor = 1; plus
±0.7% for crest factor = 1 to 3; and
±2.5% for crest factor = 5
Range: 5A AC, true RMS
Frequency: 40 to 1000 Hz
Impedance: 0.02 ohms (shunt out-
put capacitive coupled)
Overrange: 10A Maximum
Accuracy: ±0.4% of reading,
±0.13% FS, ±0.5 digit, and ±200
PPM/°C for crest factor = 1; plus
±0.7% for crest factor = 1 to 3; and
±2.5% for crest factor = 5
Range: 4 – 20 mA DC, 0 – 10V DC,
1 – 5V DC; separate input
terminals for voltage and current
signals
Impedance: 100
and 1.27 M
Overrange: 50 mA maximum (cur-
rent input) and 100V maximum
(voltage input)
Power Output: 24V DC ±10%, 90
mA max, short circuit protected
Accuracy: ±0.1% of reading,
±0.03% FS, ±0.5 digit, and ±80
PPM/°C
Dual relay: 1 set of form C
contacts each
Contact rating; 5A, 250V AC or
30V DC
Isolation dielectric strength:
2300V AC
Output Signals: 4 – 20 mA
(<750
Accuracy: 0.13% FS, 100 PPM/°C,
0.07% FS change with 4 – 20 mA
load, ±0.3% FS for 4 – 20 mA
output, only after exposure to
85% relative humidity
Isolation dielectric strength:
2300V AC to signal inputs, relays
and AC power input; 500V AC to
RS-485 and DC power inputs
) and 0 – 10V (>2500
(voltage input)
(current input)
)
59

Related parts for 57701461