6.4.1
The Line Port Selection register selects the register bank that is associated with the
addressed line port. All line port specific register operations - line port specific registers
are indicated by a ’4’ in the last column of the register summary - are performed on the
line port that is addressed by the value of LP_SEL.
LP_SEL
Reset value: 00
LN2,1
U-Interface Registers
6.4.2
The Operation Mode register determines the operating mode of the DFE-Q V2.1 in all
ports.
OPMODE
Reset value: 02
Data Sheet
7
0
7
0
Detailed Register Description
LP_SEL - Line Port Selection Register
OPMODE - Operation Mode Register
Line Port Number
00 =
01 =
10 =
11 =
H
H
6
0
6
0
Line port no. 0 is addressed by the following command
Line port no. 1 is addressed by the following command
Line port no. 2 is addressed by the following command
Line port no. 3 is addressed by the following command
FEBE
5
0
5
4
0
4
0
read/write
read*
121
)
/write
3
0
3
0
2
0
2
0
Register Description
Address: 1C
Address: 00
LN2
1
1
1
PEF 24911
2001-07-16
LN1
0
0
0
H
H