PEB24911HV13NT Lantiq, PEB24911HV13NT Datasheet - Page 78
PEB24911HV13NT
Manufacturer Part Number
PEB24911HV13NT
Description
Manufacturer
Lantiq
Datasheet
1.PEB24911HV13NT.pdf
(155 pages)
Specifications of PEB24911HV13NT
Control Interface
HDLC
Lead Free Status / Rohs Status
Supplier Unconfirmed
- Current page: 78 of 155
- Download datasheet (3Mb)
PEF 24911
Functional Description
Wait for TN
In “Wait for TN” the U-transceiver waits for a response (tone TN from the NT or tone TL
in case of an analog loop-back) to the transmission of the wake-up signal TL. If no
response is received within T3, the state is left for re-transmission of a wake-up tone TL.
This procedure is repeated until the detection of tone TN or until expiry of timer T1. In
this case the C/I-channel indication EI3 is issued, but no state change is performed.
Data Sheet
68
2001-07-16
Related parts for PEB24911HV13NT
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet: