FLUKE-8846A NIST W/DATA Fluke, FLUKE-8846A NIST W/DATA Datasheet

no-image

FLUKE-8846A NIST W/DATA

Manufacturer Part Number
FLUKE-8846A NIST W/DATA
Description
Digital Multimeters 6.5 BENCH DMM NIST W/DATA
Manufacturer
Fluke

Specifications of FLUKE-8846A NIST W/DATA

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2132558
Fluke 8845A/8846A
The Fluke 8845A and 8846A 6.5 digit precision multime-
ters have the precision and versatility to handle your most
demanding measurements, on the bench or in a system.
These meters are both high performance and feature rich,
yet also remarkably easy to use.
Features at a glance
6.5 digit resolution
Basic V dc accuracy of up to 0.0024 % (1 yr.)
Dual display
100 μA to 10 A current range, with up to 100 pA resolution
Wide ohms ranges from 10 W to 1 GW with up to 10 μW resolution
2 x 4 ohms 4-wire measurement technique
Both models measure frequency and period
8846A also measures capacitance and temperature
USB memory drive port (8846A)
Fluke 45 and Agilent 34401A emulation
Graphical display
Trendplot
CAT I 1000 V, CAT II 600 V
Digital Multimeters
paperless recorder mode, statistics, histogram
Extended Specifications
perform the functions you would
expect to see in a multifunction
DMM, including measuring
volts, ohms, and amps, with
performance that exceeds expec-
tations. Basic V dc accuracy of
up to 0.0024 %, 10 A current
range, and a wide ohms range
from 10 W to 1 GW with up
to 10 μW resolution give you
an unbeatable combination of
measurement capability.
and 8846A to measure tempera-
ture, capacitance, period, and
frequency—the functions of a
counter, capacitance meter, and
thermometer are built in for
unparalleled versatility. Extend
the meters’ utility even more
with their graphical display
modes, including Trendplot
paperless recorder mode, statis-
tics and histograms—features you
won’t find on other multimeters.
also durable and dependable,
features you expect from any
Fluke meter. This unique combi-
nation of features and perfor-
mance makes the 8845A and
8846A an unbeatable value for
a wide variety of applications,
including manufacturing test,
research and development, and
service.
These digital multimeters
You can also use the 8845A
Of course, these meters are

FLUKE-8846A NIST W/DATA Summary of contents

Page 1

... Fluke 8845A/8846A Digital Multimeters Extended Specifications The Fluke 8845A and 8846A 6.5 digit precision multime- ters have the precision and versatility to handle your most demanding measurements, on the bench system. These meters are both high performance and feature rich, yet also remarkably easy to use. ...

Page 2

... Gigabyte capacity with USB memory module Math Functions Zero, dBm, dB, MX+B, Offset, DCV ratio and TrendPlot, Histogram, Statistics (min/max/average/standard deviation), and Limit Test General Specifications 28 ° °C < ° °C <50 % (available separately, see “Accessories”) through front-panel USB port 8845A and 8846A Fluke Corporation 1 ...

Page 3

... V 0.0018 + 0.0006 1000 V 0.0018 + 0.0006 2 Fluke Corporation 8845A and 8846A 750 V ac (8845A), Diode, and 10 A ranges Electrical Specifications 100 dB for NPLC greater with analog filter on and power line frequency ±0.1 % minutes, add error: 0.0002 % range additional error + 5 μV. ...

Page 4

... Input Impedance 1 MΩ ±2 % shunted by <100 pf 8845A and 8846A Fluke Corporation 3 ...

Page 5

... Hz – 20 kHz 20 – 50 kHz 50 – 100 kHz [2] 100 – 300 kHz [1] [2] [1] Typically 30 % reading error at 1 MHz [2] 750 Volt range is limited Fluke Corporation 8845A and 8846A 24 Hour 90 Days 1 Year (23 ±1 °C) (23 ±5 °C) (23 ±5 °C) 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 ...

Page 6

... Source Current 5 mA/ mA mA/6 V 100 μA/6 V 100 μA/ μA/ μA/ μ MΩ/ μ MΩ/10 V 8845A and 8846A Fluke Corporation 5 ...

Page 7

... A [2] 0.1 + 0.008 [1] Part range [2] Available at front panel connectors only [3] 400 mA available in software version 2.0 or greater only. 400 mA continuously; 550 mA for 2 minutes on, 1 minute off. 6 Fluke Corporation 8845A and 8846A NPLC Additional NPLC Noise Error 100 range range 1 0.001 % of range 0.2 0.003 % of range ± ...

Page 8

... Additional NPLC Noise Error for 100 μ range range 0. range 0. range ±4 μA 0. range ±4 μA Burden Voltage <0.015 V <0.15 V <0.025 V <0.25 V <0.50 V <0.05 V <0.05 V <0.5 V 8845A and 8846A Fluke Corporation 7 ...

Page 9

... Hz 5 – – 1 kHz 1kHz – 10 kHz [2] 3 – – – 5 kHz 5 – 10 kHz 8 Fluke Corporation 8845A and 8846A 24 Hour 90 Days 1 Year (23 ±1 °C) (23 ±5 °C) (23 ±5 °C) 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 ...

Page 10

... Outside °C 0.1 0.1 0.005 0.05 0.05 0.005 0.03 0.03 0.001 0.01 0.01 0.001 0.01 0.01 0.001 Temperature Coefficient/ °C 0.1 + 0.006 0.035 + 0.006 0.015 + 0.006 0.03 + 0.006 0.2 + 0.006 0.035 + 0.006 0.015 + 0.006 0.03 + 0.006 8845A and 8846A Fluke Corporation 9 ...

Page 11

... Fluke Corporation 8845A and 8846A Temperature 24 Hour 90 Days 1 Year Compensation/ °C (23 ±1 °C) (23 ±5 °C) (23 ±5 °C) Outside °C 0.1 ...

Page 12

... For more information call: In the U.S.A. (800) 443-5853 or ® Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006-2008 Fluke Corporation. ...