3130-F212-P7T1-S01Q-3A E-T-A Circuit Protection and Control, 3130-F212-P7T1-S01Q-3A Datasheet

no-image

3130-F212-P7T1-S01Q-3A

Manufacturer Part Number
3130-F212-P7T1-S01Q-3A
Description
IP66 RATED SEALED CIRCUIT BREAKER/ SWITCH WITH BLACK ACTUATOR
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 3130-F212-P7T1-S01Q-3A

Actuator Type
Rocker
Brand/series
3130
Characteristic
Thermal
Current, Rating
3 A
Mounting Type
Panel
Number Of Poles
1
Termination
Blade
Voltage, Rating
240/50 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Single pole rocker switch/thermal trip free circuit breakers (S-type TO
CBE to EN 60934) of compact design for snap-in panel mounting.
Available either with protection on one/both/all poles or, in the case
of the double pole version, protection on one pole only. Illumination is
optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, household and office machines,
electrical tools, mobile homes, boating, construction vehicles, medical
equipment to EN 60601.
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
operating voltage
12 V
24 V
48 V
115 V
230 V
Authority
VDE (EN 60934)
UL, CSA
Issue C
Description
Typical applications
Standard current ratings and typical internal resistance values
Illumination voltage/power consumption
Approvals
Internal resistance
per pole (Ω)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Thermal Overcurrent Circuit Breaker 3130
Voltage rating
AC 240/415 V
DC 50 V
DC 28 V
AC 250 V, DC 50 V
filament/neon (B)
20 mA
20 mA
20 mA
< 1.5 mA
< 1.5 mA
power consumption
Current
rating (A) per pole (Ω)
4
5
6
7
8
10
12
14
15
16
18
20
Current rating
0.1...20 A
0.1...8 A
0.1...20 A
0.1...16 A
Internal resistance
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
LED (G, R, Y)
9 mA
9 mA
1.5 mA
< 1 mA
< 1 mA
www.e-t-a.com
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
inductive
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
AC 240 V:
DC 50 V:
DC 28 V:
operating area
current path/current path AC 1,500 V
0.1...20 A 30,000 operations at 1 x I
0.1...4 A
4.5...16 A 30,000 operations at 1 x I
4.5...20 A 30,000 operations at 1 x I
water splash protected (IP 66)
cn
AC 240 V; DC 50 V
(UL: AC 250 V; DC 50 V)
0.1...20 A
30,000 operations at 1 x I
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
0.1...2 A
2.5...20 A
0.1...12 A
AC 250 V/3,500 A
DC 50 V/2,000 A
operating area IP66
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 17 g
3130
10 x I
150 A
N
14...16 A
AC 250 V/3,500 A
DC 50 V/2,000 A
pollution
degree
2
N
N
N
N
, inductive
, inductive
, resistive
,
1 - 87
1

Related parts for 3130-F212-P7T1-S01Q-3A

3130-F212-P7T1-S01Q-3A Summary of contents

Page 1

... Thermal Overcurrent Circuit Breaker 3130 Description Single pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours ...

Page 2

... Thermal Overcurrent Circuit Breaker 3130 Ordering information - IP66 Type No. 3130 rocker switch/circuit breaker Mounting F snap in frame Frame 2 splash water protected Number of poles 1 single pole, thermally protected 1 A 1-pole, unprotected ** Frame mounting 2 panel thickness 2-3.5 mm Terminal design P7 blade terminals DIN 46244-C-Ms-S (QC 2x.110) H7 for terminals 1 ...

Page 3

... Thermal Overcurrent Circuit Breaker 3130 Internal connection diagrams 1-pole line I.I I.2 lamp load 1-pole switch 1-pole momentary switch line I.I I.3 lamp load Issue C Typical time/current characteristics 0.1…2 A 10000 1000 100 10 line I.I 1 I.3 lamp 0.1 load 1 2.5…20 A ...

Page 4

... Thermal Overcurrent Circuit Breaker 3130 Rocker How to exchange rockers X 222 420 .. symbol 1 X 222 420 12 I.3 Symbols/legends available Interior light Anchor light Cockpit light Navigation light VHF radio Refrigerator Anchor Windshield wiper Bilge pump Potable water Horn Ventilation fan Panel light ...

Related keywords