DSO6014A Agilent Technologies Test Equipment, DSO6014A Datasheet

no-image

DSO6014A

Manufacturer Part Number
DSO6014A
Description
Oscilloscope, 4 CHannel, 100 MHz
Manufacturer
Agilent Technologies Test Equipment
Type
Digitalr
Datasheet

Specifications of DSO6014A

Bandwidth
100 MHz
Brand/series
DSO6000A Series
Configuration
Bench/Portable
Display Type
Color TFT LCD
Memory
8 Mpts
Number Of Channels
4
Sample Rate
2 GS/s
If you haven’t purchased an Agilent scope lately,
why should you consider one now?
Agilent has been the fastest growing oscilloscope supplier since 1997
Data, 2007)
advanced technology that will allow you to see more subtle signal detail and more
infrequent events than any other scope on the market. See the Infi niiVision 6000
Series oscilloscope—the industry’s best for signal viewing.
The Infi niiVision 6000 Series offers bandwidths up to 1 GHz. Each model, equipped with a 6.3” XGA LCD display, comes in
a whisper-quiet package that weighs only 11 pounds.
Choose from sixteen Infi niiVision 6000 Series models. Agilent provides an easy 5-minute DSO-to-MSO upgrade kit for
previously purchased 6000 Series DSOs.
2
Model
DSO6012A
DSO6014A
MSO6012A
MSO6014A
DSO6032A
DSO6034A
MSO6032A
MSO6034A
DSO6052A
DSO6054A
MSO6052A
MSO6054A
DSO6102A
DSO6104A
MSO6102A
MSO6104A
.
Wonder why? Agilent engineers developed the Infi niiVision 6000 Series with
Bandwidth
100 MHz
300 MHz
500 MHz
1 GHz
Sample rate
2 GSa/s
2 GSa/s
4 GSa/s
4 GSa/s
Memory
8 Mpts
8 Mpts
8 Mpts
8 Mpts
Scope channels
(source: Prima
2
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
Digital channels
There is no better way to experience
the superiority of the Infi niiVision 6000
Series scopes than to see it.
Contact Agilent today to request an
evaluation.
16
16
16
16
deep-memory waveforms
per second, even with
deep memory, digital
channels and serial
decode turned on.
Update rate
Up to 100,000

DSO6014A Summary of contents

Page 1

... Series oscilloscope—the industry’s best for signal viewing. The Infi niiVision 6000 Series offers bandwidths GHz. Each model, equipped with a 6.3” XGA LCD display, comes in a whisper-quiet package that weighs only 11 pounds. Model Bandwidth Sample rate DSO6012A DSO6014A 100 MHz 2 GSa/s MSO6012A MSO6014A DSO6032A DSO6034A ...

Page 2

... What gives the Infi niiVision 6000 Series the best signal visibility? 1. High resolution Oscilloscopes are visual tools and high-resolution screens make the product better. High resolution displays have become increasingly impor- tant as general purpose scopes need to display digital and serial signals in addition to traditional scope channels ...

Page 3

... Agilent Infi niiVision Portfolio Agilent’s Infi niiVision lineup includes 5000, 6000 and 7000 Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specifi c needs. Largest display, shallow depth ...

Page 4

Performance characteristics Acquisition: scope channels Sample rate Memory depth Vertical resolution Peak detection Averaging High resolution mode Filter Acquisition: digital channels (MSO6000A or MSO-upgraded DSO6000A only) Sample rate Maximum input frequency Memory depth Vertical resolution Glitch detection * Half channel ...

Page 5

Performance characteristics Vertical system: scope channels Scope channels Bandwidth (–3dB)* AC coupled Calculated rise time (=0.35/bandwidth) Single-shot bandwidth Range 1 Maximum input Offset range Dynamic range Input impedance Coupling BW limit Channel-to-channel isolation Standard probes Probe ID * Denotes warranted ...

Page 6

Performance characteristics Vertical system: scope channels (continued) ESD tolerance Noise, RMS, input shorted 1 DC vertical gain accuracy* DC vertical offset accuracy Single cursor accuracy 1 Dual cursor accuracy Denotes warranted specifications, all others are typical. Specifications are ...

Page 7

Performance characteristics Horizontal Range Resolution Time scale accuracy* Vernier Delay range Analog delta-t accuracy Logic delta-t accuracy Modes XY Reference positions Segmented memory rearm time Trigger system Sources Modes Holdoff time Trigger jitter * Denotes warranted specifications for units manufactured ...

Page 8

Performance characteristics Trigger system (continued) Selections Edge Pattern Pulse width TV Sequence CAN LIN FlexRay USB SPI RS-232/UART Duration Nth edge burst 20 (continued) Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay, USB, I Nth ...

Page 9

... MHz to bandwidth of oscilloscope: 500 mV AC (~3.5 Hz), DC, noise reject, HF reject and LF reject (~50 kHz) MSO/DSO601xA: Auto probe sense MSO/DSO603xA/605xA/610xA: Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense MSO/DSO6xx4A (4-/4+16-ch models) MSO/DSO6014A: 1.015 kΩ ±5% MSO/DSO6034A/6054A/6104A: 2.14 kΩ ±5% ±15 V ±5 V MSO/DSO6014A: ...

Page 10

Performance characteristics Display system Display Throughput of scope channels Resolution Controls Built-in help system Real-time clock Measurement features Automatic measurements Voltage (scope channels only) Time Counter Threshold definition Cursors Waveform math Measurement statistics 22 (continued) 6.3-inch (161 mm) diagonal color ...

Page 11

Performance characteristics Storage Save/recall (non-volatile) Storage type and format FFT Points Source of FFT Window Noise floor Amplitude Frequency resolution Maximum frequency I/O Standard ports Max transfer rate Supported printers via USB General characteristics Physical size Weight Probe comp output ...

Page 12

Performance characteristics General characteristics (continued) Trigger out 10 MHz ref in/out Kensington lock Power requirements Line voltage range Line frequency Power usage Battery option – BAT Environmental characteristics Ambient temperature Humidity Altitude Vibration Shock Pollution degree Indoor use Other Measurement ...

Page 13

... Ordering information Model Bandwidth DSO6012A 100 MHz MSO6012A 100 MHz DSO6014A 100 MHz MSO6014A 100 MHz DSO6032A 300 MHz MSO6032A 300 MHz DSO6034A 300 MHz MSO6034A 300 MHz DSO6052A 500 MHz MSO6052A 500 MHz DSO6054A 500 MHz MSO6054A 500 MHz DSO6102A ...