TD-71628 Macromatic, TD-71628 Datasheet - Page 2

no-image

TD-71628

Manufacturer Part Number
TD-71628
Description
Relay; E-Mech; Timing; Off Delay; DPDT; Cur-Rtg 10A; Ctrl-V 24AC/DC; Socket Mnt; 11 Pin
Manufacturer
Macromatic
Datasheet

Specifications of TD-71628

Brand/series
TD-7 Series
Contact Form
DPDT
Current, Rating
10 A
Function
Timing
Mounting Type
Socket
Number Of Pins
11
Power, Rating
3 VA
Relay Type
Electro Mechanical
Reset Time
0.1 Sec. (On Delay⁄Interval⁄Flasher)
Standards
cUL, UL, CSA, CE
Temperature, Operating, Maximum
65 °C
Temperature, Operating, Minimum
-28 °C
Termination
Plug-In
Timer Type
Off Delay
Timing Range
50 ms to 900 hrs.
Voltage, Control
24 VAC⁄VDC
Voltage, Rating
240⁄30 VAC⁄VDC
Temperature
–28° to +65°C
Dimensions
1.7" × 2.4" × 3.2"
Lead Free Status / Rohs Status
RoHS Compliant part
Voltage Tolerance:
AC Operation:
DC Operation:
Load (Burden):
3 VA
Setting Accuracy:
Repeat Accuracy (constant voltage and temperature):
+0.1% of set time or +0.02 seconds, whichever is greater.
Reset Time:
On Delay/Interval/Flasher: 0.1 Seconds
Off Delay/Single Shot: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
12, 24 & 48V units
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Temperature:
12-120V Input Voltage: -28
240V Input Voltage:
Insulation Voltage:
2,000 volts
Dimensions
Revised: 11/07
Application Data
+1% of set time or +50ms, whichever is greater.
+10/-15% of nominal at 50/60 Hz.
+10/-15% of nominal.
0.05 Seconds
0.08 Seconds
(60)
2.4
-28
o
o
to 65
to 50
o
o
C (-18
C (-18
o
o
to 150
to 122
(43)
1.7
o
o
F)
F)
Programmable Multi-Range Plug-in
Output Contacts:
DPDT 10A @ 240V AC/30V DC,
1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120V AC (N.C.)
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
Do not use a solid state switch to initiate the timing sequence-
problems with leakage current could occur. Contact Macro-
matic Controls for additional information.
Triggering Off Delay or Single Shot Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time is
0.1 seconds.
LED:
Flasher Mode:
All Other Modes: Flashes during timing; continuous on after
Approvals:
File #E109466
TIME DELAY RELAYS
Time Ranger
File #LR45565
Flashes during “ON” time; continuous on
during “OFF” time
time out.
Application Data & Dimensions
(74)
2.9
(77)
3.0
EN60947-1, EN60947-5-1
EMC Directives
Low Voltage &
TM
Inches (Millimeters)
Digital-Set
All Dimensions in
File #E109466
with
appropriate
socket
47