8301-1110 Redington Counters, Inc., 8301-1110 Datasheet - Page 6

no-image

8301-1110

Manufacturer Part Number
8301-1110
Description
Counter; Screw; 0 to 50 degC
Manufacturer
Redington Counters, Inc.
Type
Counterr
Datasheet

Specifications of 8301-1110

Cut Out, Panel
1/16 DIN
Digit Height
0.32
Dimensions
4.54"L×1.95"W×1.95"H
Display Digit Height
0.3" (Main), 0.2" (Secondary)
Display Type
LCD
Function
Counter
Material, Casing
Black Plastic
Number Of Digits
7
Primary Type
Electronic
Range, Measurement
0 to 999999
Temperature, Operating, Range
0 to 50 °C
Terminal Type
Screw
Termination
Screw Clamp
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
7. USER INPUTS: Configurable as current sinking (active low), or
8. OUTPUTS: (Output type and quantity model dependent)
9. RS485 SERIAL COMMUNICATIONS (Optional): Up to 32 units can
10. CERTIFICATIONS AND COMPLIANCES:
Relay: Form A contact, rating = 5 A @ 250 VAC, 30 VDC (resistive
UL Recognized Component, File # E195514
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
CE Compliant:
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
electrostatic discharge
electromagnetic RF fields
fast transients
RF conducted interference
simulation of cordless phone
Emissions to EN 50081-2
RF interference
Solid-State:
be connected.
Relay Life Expectancy: 100,000 cycles min. at max. load rating.
Programmable Timed Output:
NPN Open Collector: I SNK = 100mA max. @ V OL = 1.1 VDC
PNP Open Collector: I SRC = 100mA max. ( See note) ; V OH =
Baud Rate: Programmable from 1200 to 9600 baud.
Address:
Data Format:10 Bit Frame, 1 start bit , 7 or 8 data bits, 1 or no
Parity:
Note: The internal supply of the 83 counter can provide a total
of 100 mA for the combination of sensor current and PNP
output sourcing current. The supply voltage is +12 VDC (+/-15
%), which will be the PNP output voltage level when using only
the internal supply.
If additional PNP output sourcing current or a higher output
voltage level is desired, an external DC supply may be
connected between the “DC Out/In” and “Comm” terminals.
This supply will determine the PNP output voltage level, and
must be in range of +13 to 30 VDC.
An external supply can provide the additional output sourcing
current required in applications where two or more outputs are
“ON” simultaneously. However, the maximum rating of 100mA
per individual output must not be exceeded, regardless of
external supply capacity.
load) , 1/10 HP @ 120 VAC (inductive load).
Inhibit Response Time: 250 microsec max.
Current Sinking: (active low) : V IL = 1.5 VDC max. 22 K
Current Sourcing: (active high): V IH =3.5 min. V IN max. =
Response Time: 10 msec. max.
Model 83
0.01 Second Resolution: 0.01 to 99.99 sec., +/-0.01%
0.1 Second Resolution:
current sourcing (active high) inputs via a single plug
jumper.
Programmable from 0 to 99.
Parity bit, and 1 stop bit.
Programmable for Odd (7 data bits), Even ( 7 data
bits) or None ( 8 data bits).
max. ;V OH = 30 VDC max.
12 VDC +/-15% ( using internal supply);
V OH = 13 to 30 VDC ( using external
supply).
+20 msec max. (Prescalers less
than 2)
0.1 to 999.9 sec. +/- 0.01 + 100
msec max. (Prescalers less
than 2)
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN V502204
EN 55011
User selectable output time
resolutions.
ohm pull-ups to 5 VDC
30 VDC; 22K ohm pull-down.
enclosure class A
Electronic
11. ENVIRONMENTAL CONDITIONS:
Altitude : Up to 6500 Feet [1981 Meters]
12. ELECTRICAL CONNECTIONS:
13. CONSTRUCTION: Black plastic case with collar style panel latch.
14. WEIGHT: 6.0 oz [170g]
SINGLE PRESET MODELS
DUAL PRESET MODELS
3 PRESET BATCH MODELS
PRESCALER OUTPUT MODELS
output. The solid-state output is available as an NPN or PNP open
collector transistor.
These outputs can be relay or solid-state outputs. The solid-state
outputs are available as NPN or PNP open-collector transistors. Units
with solid-state outputs can be ordered with an optional prescaler
output.
counting, or to keep a total count. This second counter can be
programmed to operate in one of eight operating modes. Output 1 and
2 are assigned to the primary process counter (C1). Output 3 is
assigned to the secondary Batch/Total counter (C2). The three preset
batch unit can be ordered with solid-state or relay outputs. Units with
solid-state outputs have a User Input 2 terminal available. The relay
model has a relay output for Output 2 and Output 3 (Batch/Total).
Output 1 is available only as solid-state.
models have an additional output configured as a prescaler output.
Each time the least significant digit of the display increments, the
Prescaler output provides a pulse. The width of this pulse is variable in
that the output will turn off after a programmed number of count input
pulses has occurred (1-9). The Prescaler output can also be
programmed to activate when the 10’s digit of the display increments,
rather than the least significant digit.
Note: Prescaler Output Models are limited to two programmable count
The 8301 has a solid-state output that operates in parallel with a relay
The 8302 has two outputs that are activated from presets 1 and 2.
The 8303 has a secondary counter that can be used for batch
The 8304 is a dual preset counter with solid-state outputs. These
Operating Temperature:
Storage Temperature:
Operating and Storage Humidity: 85% max. relative humidity (
The panel latch can be installed for horizontal or vertical stacking.
Black plastic textured bezel can be removed from the case without
removing the case from the panel or disconnecting the wiring. Front
panel meets NEMA4X/IP65 requirements for indoor use, when
properly installed. Installation Category II, Pollution Degree 2.
modes and prescaler values of 1.00000 or less. See Count
Input Modes for available modes.
- Cycles through secondary displays.
- Enters Programming Mode or Protected Value Menu when
- Scrolls through programming displays.
- Enters Data Values.
- Performs user Programmed Function.
- Selects next available mode in programming mode.
- Increments digit in digit Entry mode.
- Increments value in Auto Scrolling entry mode.
- Selects Digit to right when in Digit Entry mode.
- Decrements value in Auto Scrolling entry mode.
pushed and held for 2 seconds.
LCD Predetermining Counter
FRONT PANEL KEYPAD
+32°F to +122°F [0°C TO +50°C]
-40°F to +158°F [-40°C to +70°C]
Wire clamping screw terminals.
+122°F [0°C to +50°C]
non-condensing) from +32°F to
91

Related parts for 8301-1110