CPM2A-20CDR-A Omron Automation, CPM2A-20CDR-A Datasheet - Page 2

no-image

CPM2A-20CDR-A

Manufacturer Part Number
CPM2A-20CDR-A
Description
CONTROLLER; MICRO PROGRAMMABLE; 20 I/O POINTS; 12 DC INPUTS; 8 OUTPUTS; AC PWR S
Manufacturer
Omron Automation
Type
PLCr
Datasheet

Specifications of CPM2A-20CDR-A

Brand/series
CPM2A Series
Communication
RS-232C
Dimensions
130mmL×90mmW×90mmD
Mounting Type
Panel
Number Of Inputs
12
Number Of Outputs
8
Output Type
Relay
Primary Type
Controller
Standards
UL, CSA
Terminal Type
Screw
Termination
Screw
Voltage, Supply
100-240 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
General
Note: Use the external power supply as the power supply for input devices only. (It cannot be used as to drive output devices.) If the external power
Power Consumption for CPM2A CPU
Units with DC Power Supplies
Use the following information when computing CPM2A power capacities.
66
Item
Supply voltage
Operating voltage range
Power consumption
Inrush current
External power supply
(AC power supplies only)
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient temperature
Humidity
Atmosphere
Terminal screw size
Power interrupt time
CPU Unit weight
Expansion Unit weight
CPM2A CPU Unit
CPM2A-20CDR-D
CPM2A-30CDR-D
CPM2A-40CDR-D
CPM2A-60CDR-D
CPM2A-20CDT/T1-D
CPM2A-30CDT/T1-D
CPM2A-40CDT/T1-D
CPM2A-60CDT/T1-D
Specifications
supply current exceeds the rated current, or there is a short-circuit, the external power supply voltage will drop and PC operation will stop.
If there are 3 CPM1A-MAD11 Units mounted to a CPM2A-60CDR-A, the current for the external power supply must not exceed 200 mA.
AC power
DC power
AC power
DC power
AC power
DC power
AC power
DC power
Supply voltage
Output capacity
AC power
DC power
CPU Units with
20 I/O points
100 to 240 V AC, 50/60 Hz
24 V DC
85 to 264 V AC
20.4 to 26.4 V DC
60 VA max.
20 W max. (See separate table following this one for details.)
60 A max.
20 A max.
24 V DC
300 mA (See note)
20 M min. (at 500 V DC) between the external AC terminals and protective earth terminals
2,300 V AC 50/60 Hz for 1 min between the external AC and protective earth terminals, leakage current: 10 mA
max.
Conforms to IEC61000-4-4, 2 kV (power lines)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
each
(Time coefficient; 8 minutes
147 m/s
Operating: 0 to 55 C
Storage: –20 to 75 C
10% to 90% (with no condensation)
Must be free from corrosive gas
M3
AC power supply: 10 ms min.
DC power supply: 2 ms min.
650 g max.
550 g max.
Units with 20 I/O Points:
Units with 8 Output Points:
Units with 8 Input Points:
MAD01 Analog I/O Unit:
MAD11 Analog I/O Unit:
AD041/DA041 Analog I/O units: 200 g max.
Temperature Sensor Units
CompoBus/S I/O Link Units:
DeviceNet I/O Link Unit:
PROFIBUS-DP I/O Link Unit:
Power consumption (W)
4
4.5
6
7.5
3.5
4
4.5
5
2
three times each in X, Y, and Z directions
CPU Units with
30 I/O points
700 g max.
600 g max.
coefficient factor 10 = total time 80 minutes)
Note: When calculating the total power consumption, it is also neces-
CPM1A Expansion I/O Unit or Expansion Unit
CPM1A-20EDR1
CPM1A-20EDT/T1
CPM1A-8ED
CPM1A-8ER
CPM1A-8ET/T1
CPM1A-DRT21
CPM1A-SRT21
CPM1A-MAD01/MAD11
CPM1A-TS001/TS101
CPM1A-TS002/TS102
CPM1A-PRT21
CPM1A-TS101-DA
CPM1A-AD041
CPM1A-DA041
300 g max.
250 g max.
200 g max.
150 g max.
250 g max.
250 g max.
200 g max.
200 g max.
150 g max.
sary to include the power consumption of Programming Con-
soles, RS-232C Adapter Units, and other devices.
CPU Units with
40 I/O points
800 g max.
700 g max.
2
in X, Y, and Z directions for 80 minutes
Programmable Controllers
CPU Units with
60 I/O points
1,000 g max.
900 g max.
Power consumption (W)
2.5
1.5
1
2
1
1
1
3.5
3
3
1
1.5
3
3.3

Related parts for CPM2A-20CDR-A