SF-C13 Panasonic Electric Works, SF-C13 Datasheet - Page 3

no-image

SF-C13

Manufacturer Part Number
SF-C13
Description
Relay; Hybrid; Sfty; Cur-Rtg 100mA; Ctrl-V 24DC; Plug-in; cULus, CE, OSHA/ANSI
Manufacturer
Panasonic Electric Works
Datasheet

Specifications of SF-C13

Current, Rating
100 mA
Function
Safety
Relay Type
Hybrid
Standards
cULus, CE, OSHA⁄ANSI
Termination
Plug-In
Voltage, Control
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
19
SF4B
SPECIFICATIONS
Exclusive control unit
Notes: 1)
Item
Connectable light curtains
Applicable standard
Control category
Supply voltage
Current consumption
Fuse (power supply)
Enabling path
Pick-up delay (Auto reset / Manual reset)
Response time
Auxiliary output
Semiconductor auxiliary output
(AUX)
External relay monitor function
Trailing edge function
Polarity selection function
Excess voltage category
Pollution level
Connection terminal
Enclosure material
Net weight
Application category
Rated operation voltage (Ue) /
Rated operation current (le)
Contact material / contacts
Contact resistance
Contact protection fuse rated
Mechanical lifetime
Electrical lifetime
Rated operation voltage / current
Contact protection fuse rated
Output operation
Power supply (Ui)
Enabling path [OUT (Note 3)]
Interlock (INTERLOCK)
Fault (FAULT)
Protection
Ambient temperature
Ambient humidity
Vibration resistance
2)
3)
4)
If several SF-C11 or SF-C13 units are being used in line together, leave a
space of 5 mm
each other, reduce the rated operating current for safety output in
accordance with the ambient operating temperature as shown in the graphs
at right.
Relay switching lifetime will vary depending on factors such as the type of
load, the switching frequency, and ambient conditions.
The operation indicator is marked as ‘Enabling’ on the unit for SF-C12.
Terminals for utilizing the functions of the SF4B series are available.
Model No.
0.197 in
10 to 55 Hz frequency, 0.35 mm
30 V DC / 6 A, 230 V AC / 6 A, resi s ti v e l o ad (For i n duced l o ad, duri n g contact protecti o n)
Minute current: 10 mA or more (at 24 V DC)(Note 1)
Safety relay contact (NC contact) 1 (41-42) (Related to enabling path)
<
(
Yellow LED (lights up when enabling contacts are opened)
24 V DC / 2 A, Minute current: 10 mA or more (at 24 V DC)
Related to auxiliary output of light curtain
or more between each unit. If the units are touching
between the semiconductor
auxiliary output and
Minus ground (Setting for PNP)
Max. source current: 60 mA
Applied voltage: same as supply voltage
Residual voltage: 2.3 V or less
Leakage current: 2 mA or less
NO contact
30 to 85 %RH, Storage: 30 to 95 %RH
Detachable-type spring gauge terminal
AgSnO, self cleaning, positively driven
Yellow LED (blinks when fault occurs)
(at source current 60 mA)
Enclosure: IP40, Terminal: IP20
10 to
100 m or less (initial value)
80 ms or less / 90 ms or less
Incorporated (Sliding switch allows selection of plus / minus ground)
Plus ground: Correspond to NPN output light curtain
Minus ground: Correspond to PNP output light curtain
6 A (slow blow)
2 A (slow blow)
0.014 i n
320 g approx.
10 ms or less
55 C
Incorporated
SF-C11
3 (13-14, 23-24, 33-34)
V
ampl i t ude i n X, Y, and Z di r ecti o ns for twenty ti m es each
ABS
>
100,000 times or more (switching frequency 20 times/min, 230 V AC / 3 A resistive load)
)
<
(
between the semiconductor
auxiliary output and 0 V
Max. sink current: 60 mA
Applied voltage: same as supply voltage
Residual voltage: 1.5 V or less
Leakage current: 2 mA or less
Plus ground (Setting for NPN)
Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
14 to
ISO 13849-1 (EN 954-1, JIS B 9705-1) compliance up to Category 4 standards
(at sink current 60 mA)
10 million times or more (switching frequency 180 times/min.) (Note 2)
131 F
Green LED (lights up when enabling contacts are closed)
SF4B series
(No dew condensation or icing allowed), Storage:
>
)
Green LED (lights up when current flowing)
24 V DC
24 V DC / 1 A, resistive load (For induced load, during contact protection)
Minimum applicable load: 15 mA or less (at 24 V DC)
AgNiO
Safety relay contact (NC contact) 1 (31-32) (Related to enabling path)
30 V DC / 3 A, Minute current: 15 mA or less (at 24 V DC)
Orange LED (l i g hts up when two l i g ht curtai n i n put pol a ri t y sel e ct swi t ch setti n gs are di f ferent)
10 to 55 Hz frequency, 0.75 mm
IEC 61496-1, UL 61496-1, JIS B 9704-1
35 to 85 %RH, Storage: 35 to 85 %RH
100 mA or less (without light curtain)
NO contact
AC-15, DC-13 (IEC 60947-5-1)
30 ms or less / 30 ms or less
50 m or less (initial value)
0.2 !mAu, self cleaning, positively driven
Incorporated (Note 4)
Die-cast aluminium
European terminal
10 % Ripple P-P 10 % or less
<
Dilating when SF-C11 units are mounted close together
3 A (slow blow)
3 A (slow blow)
14 ms or less
Incorporated
0.030 i n
1 kg approx.
SF-C12
32
6
5
4
3
2
1
0
ampl i t ude i n X, Y, and Z di r ecti o ns for two hours each
IP65
3
2
2 (13-14, 23-24)
35
95
Ambient temperature ( C F)
104
40
113
45
122
50
131
55
10 to 55 Hz frequency, 0.35 mm
30 V DC / 4 A, 230 V AC / 4 A, resi s ti v e l o ad (For i n duced l o ad, duri n g contact protecti o n)
Minute current: 10 mA or more (at 24 V DC)(Note 1)
Yellow LED (lights up when enabling contacts are opened)
Safety relay contact (NC contact) 1 (41-42) (Related to enabling path)
PNP open collector transistor
Incorporated (Cable connection allows selection of plus / minus ground)
Plus ground: Correspond to NPN output light curtain
Minus ground: Correspond to PNP output light curtain
24 V DC / 2 A, Minute current: 10 mA or more (at 24 V DC)
Max. source current: 60 mA
Applied voltage: same as supply voltage
Residual voltage: 2.3 V or less
Leakage current: 2 mA or less
30 to 85 %RH, Storage: 30 to 95 %RH
NO contact
On when the light curtain is interrupted
>
AgSnO, self cleaning, positively driven
Yellow LED (blinks when fault occurs)
Light curtain manufactured by SUNX
Enclosure: IP40, Terminal: IP20
25 to
100 m or less (initial value)
80 ms or less / 90 ms or less
<
Spring gauge terminal
Dilating when SF-C13 units are mounted close together
4 A (slow blow)
2 A (slow blow)
0.014 i n
200 g approx.
32
70 C
10 ms or less
0
6
5
4
3
2
1
Incorporated
SF-C13
(at source current 60 mA)
3 (13-14, 23-24, 33-34)
ampl i t ude i n X, Y, and Z di r ecti o ns for twenty ti m es each
(
ABS
between the semiconductor
auxiliary output and
35
95
Ambient temperature ( C F)
13 to
104
40
113
45
158 F
122
50
V
131
55
)
>

Related parts for SF-C13