S8VM-60024C Omron Automation, S8VM-60024C Datasheet - Page 3

no-image

S8VM-60024C

Manufacturer Part Number
S8VM-60024C
Description
POWER SUPPLY, COVERED, 600 WATT, 24 VOLT, 27A
Manufacturer
Omron Automation
Datasheet

Specifications of S8VM-60024C

Brand/series
S8VM Series
Configuration
Enclosed
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 27 A
Power, Output
600 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 240 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Note: 1. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of
Item
Efficiency
Input
Output
Additional
functions
Other
2. Refer to Engineering Data (300-W, 600-W, 1,500-W Models) on page 15 to 17 for details.
3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range.
4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. Alternatively, turn OFF the remote control signal and
5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate
6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class A when the aluminum plate is
7. The measuring method conforms to JEITA standard RC-9131A. Refer to Ripple under Safety Precautions on page 32.
8. The Power Supply will not conform to safety standards if the customer replaces the fan.
the Power Supply may result in ignition or burning.
it may activate the overvoltage protection function and interrupt the output.
Supply and be sure that the load is not damaged.
then turn it back ON again.
is laid under the Power Supply. For 600-W models, insert a clamp filter (ZCAT3035-1330 by TDK: 100 Ω min. [50 to 500 MHz], or the equivalent) in the input
wire, and ring core (HF60T38X14X22 by TDK: 16 Ω typ. [1 MHz], 46 Ω typ. [10 MHz] , or the equivalent) in the output wire to reduce noise
laid under the Power Supply (1,500-W models).
Voltage (See note 1.)
Frequency (See note 1.)
Current
Power factor
Harmonic current emissions
Leakage current
Inrush current
(See note 2.)
Voltage adjustment range (See note 3.)
Ripple
Input variation influence
Load variation influence (rated input voltage) 0.6% max. (with rated input, 0 to 100% load)
Temperature variation influence
Startup time (See note 2.)
Hold time (See note 2.)
Overload protection (See note 2.)
Overvoltage protection (See note 2.)
Overheat protection (See note 2.)
Undervoltage alarm indication
Undervoltage alarm output
Power failure alarm indication
Power failure alarm output
Series operation
Parallel operation
Remote sensing function
Remote control function
Ambient operating temperature
Storage temperature
Ambient operating humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved
standards
Weight
(See note 8.)
5-V models
12-V models
15-V models
24-V models
200-V input
100-V input
200-V input
100-V input
200-V input
100-V input
200-V input
Conducted Emission
Radiated Emission
UL
cUR
cUR
EN/TUV
SEMI
100-V input
Power rating
77% min.
78% min.
79% min.
81% min.
100 to 240 VAC (85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
4.0 A max. (5 V)
4.3 A max. (12 V, 15 V, and 24 V)
2.0 A max. (5 V)
2.2 A max. (12 V, 15 V, and 24 V)
0.98 min.
0.94 min.
Conforms to EN61000-3-2
0.4 mA max.
0.75 mA max.
20 A max. (for cold start at 25°C)
40 A max. (for cold start at 25°C)
−20% to 20% (with V. ADJ)
3.8% (p-p) max. (5 V), 2.0% (p-p) max. (12 V), 2.0% (p-p) max. (15 V),
1.25% (p-p) max. (24 V), (at rated input/output voltage)
0.4% max. (at 85 to 264 VAC input, 100%)
0.02%/°C max.
1,000 ms max. (at rated input/output voltage)
20 ms typ. (15 ms min.) (at rated input/output voltage)
105% to 160% of rated load current (5 V, 12 V, and 15 V), 120% to 160% of rated
load current (S8VM-30024C), 115% to 160% of rated load current (S8VM-
60024C), voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), au-
tomatic reset
Yes (See note 4.)
Yes (See note 4.)
No
No
Yes (color: Red)
Yes (Transistor output), 30 VDC max., 50 mA max.
Yes
Yes (Up to 2 units)
Yes
Yes
Refer to the derating curve in Engineering Data (300-W, 600-W, 1,500-W Models). (with no icing or condensation) (See note 2.)
−25 to 65°C
30% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20
mA)
500 VAC for 1 min. (between all outputs and PE terminals; detection current: 100
mA)
100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100
mA)
500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20
mA)
100 MΩ min. (between all outputs and all inputs, PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions 10 to 55 Hz, 0.15-mm single amplitude for 2
150 m/s
Yes (color: Green)
Conforms to EN61204-3 EN55011 Class B and based on FCC Class B
(See note 5.)
Conforms to EN61204-3 EN55011 Class B (See note 5.)
Conforms to EN61204-3 High severity levels
UL508 (Recognition) (5 V, 12 V, and 15 V) UL508 (Listing) (24 V), UL60950-1
UL1604 (Listing; Class I/Division 2, Group A, B, C, D Hazadous Locations) (24 V)
CSA C22.2 No.14, No. 213 (Class I/Division 2, Group A, B C, D Hazadous Loca-
tions) (24 V)
CSA No. 60950-1
EN50178, EN60950-1
SELVE (EN60950-1)
SEMI F47-0200 (200-VAC input)
1,100 g max.
2
, 3 times each in ±X, ±Y, ±Z directions
300 W
When adjusting the output voltage, confirm the actual output voltage from the Power
77% min.
79% min.
80% min.
81% min.
8.0 A max. (5 V)
8.3 A max. (12 V, 15 V, and 24 V)
4.0 A max. (5 V)
4.2 A max. (12 V, 15 V, and 24 V)
1,700 g max.
600 W
---
---
---
82% min.
100 to 240 VAC (85 to 265 VAC)
20.0 A max.
11.0 A max.
0.97 min.
0.93 min.
1.5 mA max.
1.5 mA max.
1.25% (p-p) max. (See note 7.),
(at rated input/output voltage)
105% to 160% of rated load current (100 VAC),
155% to 200% of rated load current (200 VAC),
voltage drop, automatic reset (Turns OFF
when continuous for 5 s min.) (See note 4.)
3.0 kVAC for 1 min. (between all inputs and
outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and FG
terminals; detection current: 20 mA)
500 VAC for 1 min. (between all outputs and
FG terminals; detection current: 300 mA)
100 VAC for 1 min. (between all outputs and
RC terminals; detection current: 100 mA)
500 VAC for 1 min. (between all outputs and
PF terminals; detection current: 20 mA)
100 MΩ min. (between all outputs and all in-
puts, FG terminals) at 500 VDC
hours each in X, Y, and Z directions
Conforms to EN61204-3 EN55011 Class A
and based on FCC Class A (See note 6.)
Conforms to EN61204-3 EN55011 Class A
(See note 6.)
UL508, UL60950-1
CSA C22.2 No.14, CSA No. 60950-1
EN50178, EN60950-1
SELVE (EN60950-1)
3,800 g max.
If the adjuster is turned too far,
1,500 W
S8VM
4

Related parts for S8VM-60024C