ZS-28-A SMC Corporation, ZS-28-A Datasheet - Page 2
ZS-28-A
Manufacturer Part Number
ZS-28-A
Description
Connector cable for power supply output for IZE11x PNP Output Collectors
Manufacturer
SMC Corporation
Datasheet
1.IZH10-H.pdf
(7 pages)
2
Static electricity Removal Characteristics
1) Static electricity removal range / Ionizer depth direction
Air purge: No
2) Installation height of feedback sensor and discharge time / Ion balance
Air purge: Yes (0.1 MPa)
8
7
6
5
4
3
2
1
0
0
Ionizer
Horizontal distance to the ionizer - Charged object location (mm)
With feedback sensor
Without sensor
100
Charged plate
Series
Technical Data 2
Installation height of feedback sensor (mm)
Feedback sensor
Electricity removal range
200
IZS31
Height 100 mm
Height 300 mm
Height 500 mm
Discharge time from 1000 V to 100 V
300
Note) Static electricity elimination features are based on data from using a charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S. ANSI standards
400
(ANSI/ESD, STM3, 1-2000). Use this as a guideline for model selection only because the value varies depending on the material and/or size of the subject.
100 mm
500
Air purge: Yes (0.05 MPa to 0.7 MPa)
–30
–60
–90
90
60
30
0
0
Horizontal distance to the ionizer - Charged object location (mm)
100
Catalogue specification value: ±30 V
Installation height of feedback sensor (mm)
Electricity removal range
200
Height 1000 mm
Height 1500 mm
Height 2000 mm
Height 500 mm
300
400
100 mm
500