LU10-1305 Flowline, LU10-1305 Datasheet

no-image

LU10-1305

Manufacturer Part Number
LU10-1305
Description
Sensor, Submersible, Ultrasonic Level Switch-PP, Short, 3/4 in NPT, Switch-Tek
Manufacturer
Flowline
Type
Level Switchr
Datasheet

Specifications of LU10-1305

Body Style
Tubular
Brand/series
Switch-Tek
Function
Non-contact Level Detection
Ip Rating
IP68
Mounting Type
.75 In. NPT
Output
NO/NC Selectable
Sensing Mode
Ultrasonic
Special Features
Intrinsically Safe
Termination
Cable
Voltage, Supply
12 to 36 VDC
For Use With
Level Measurement
Features
Specifications
Switch-Tek
Switch-Tek
Orientation:
Accuracy:
Repeatability:
Supply voltage:
Consumption:
Contact type:
Contact rating:
Contact output:
Process temp.:
Pressure:
Sensor rating:
Sensor material:
Cable jacket mat.:
Cable type:
Cable length:
Process mount:
Mount. gasket:
Classification:
CE compliance:
Sensor material (1)
Sensor length
Process mount (2) (3)
Switch-Tek
1
2
3
4
0
2
1A relay selectable NO or NC via
power supply wiring polarity
CSA & Cenelec approved intrinsi-
cally safe for use in hazardous
areas
PP
PFA
Short
Long
3/4" NPT (US)
3/4" G / Rp (Metric)
Universal
± 1 mm in water
± 0.5 mm in water
12-36 VDC
25 mA maximum
(1) SPST relay
GP: 60 VA
IS: 32 VDC @ 0.5A
Selectable NO/NC
F: -40˚ to 176˚
C: -40˚ to 80˚
150 psi (10 bar) @ 25˚
C., derated @ 1.667
psi (.113 bar) per ˚C.
above 25˚ C.
NEMA 6 (IP68): PP
NEMA 4X (IP65): PFA
1__5: PP
2__5: PFA
1__5: PP
2__5: PFA
4-conductor, #22 AWG
(shielded)
Standard: 10' (3m)
Special order: 25'
(7.6m) or 50' (15.2m)
3/4" NPT (3/4" G / Rp)
Viton® (G version only)
Intrinsically safe
EN 61326 EMC
EN 61010-1 safety
Ordering
LU10-
Description
CSA and Cenelec approved intrinsically safe use in general purpose or hazard-
ous applications, the ultrasonic level switch is broadly applied in chemical,
waste, hydrocarbon and petroleum based liquids. Media examples include
sulfuric acid, diesel fuel and wastewater. The sensor is universally mounted
through the wall or inside the tank, and is com patible with the MicroPoint
indicator.
Approvals
CSA:
Cenelec:
Parameters
CSA:
Cenelec:
LU10-13_5
Shown
Class I, Groups A, B, C &D;
Class II, Groups E, F & G;
Class III
Class 1, Division 1, Groups A,
B, C, D; EEx ib IIC T6
Vmax = 32V, Imax = 300 mA,
Pmax = 1.3W, Ci = 0 F, Li = 0 H
Ui = 32V, Ii = 300 mA, Pi = 1.3W,
Ci = 0 F, Li = 0 H
TM
Ultrasonic Level Switch
5
Ordering Notes
1) To special order a 25' (7.6m) or 50' (15.2m)
2) The short Metric sensor is offered with
3) The straight G thread version seals with
sensor cable, place the cable length at the
end of the part number (ie: LU10-1305-25).
conical Rp threads on both sides of the
w r e n c h f l a t . T h e l o n g M e t r i c s e n s o r i s
o f f e r e d w i t h s t r a i g h t G t h r e a d s o n t h e
sensing side and conical Rp threads on
the cable side of the wrench flat.
an included Viton® mounting gasket.
LU10-14_5
Shown
Switch-Tek Ultrasonic LU10 0510 DS2_3
68
IP
LU10-23_5
Shown

Related parts for LU10-1305

LU10-1305 Summary of contents

Page 1

... MicroPoint indicator. 5 Ordering Notes 1) To special order a 25' (7.6m) or 50' (15.2m) sensor cable, place the cable length at the end of the part number (ie: LU10-1305-25). 2) The short Metric sensor is offered with conical Rp threads on both sides of the sensing side and conical Rp threads on the cable side of the wrench flat ...

Page 2

... Switch-Tek Switch-Tek LU10-_4_5 Profile RELAY Red (+) Black (-) NO/NC White Green COM Shld LU10-_3_5 Profile RELAY Red (+) (-) Black White NO/NC Green COM Shld Specifications are subject to change without notice. NO Output - DC Powered Load [Dry Condition] RED GRN Sensor (NO) SHLD WHT BLK RELAY RATING SENSOR POWER [RED & ...

Related keywords